메인 콘텐츠로 이동

PowerEdge: Assign and Unassign hot spare in system setup in PERC Controller 10

요약: This article provides the information of how to assign or unassign a global dedicated hot spare for a hard drive.

이 문서는 다음에 적용됩니다. 이 문서는 다음에 적용되지 않습니다. 이 문서는 특정 제품과 관련이 없습니다. 모든 제품 버전이 이 문서에 나와 있는 것은 아닙니다.

지침

This article provides the information of how to assign or unassign a global dedicated hot spare for a hard drive.

  • A dedicated hot spare is assigned to only one virtual disk on the controller.
  • A Global hot spare is assigned to all virtual disks on the controller.

Dell PowerEdge RAID Controller 10 (PERC H740P, PERC H745P MX, PERC H840) supports this feature. 
See the Dell PowerEdge RAID Controller manual for more information.


Table of Contents

  1. Going to Dell PERC 10 configuration utility

  2. Assign a global hot spare

  3. Assign a dedicated hot spare

  4. Unassign a hot spare


Navigating to the Dell PERC 10 configuration utility 

Perform the following steps to boot to the HII configuration utility:

  1. Turn on the system.
  2. While the system startup, press F2 to enter System Setup. 
    Entering System Setup 
     
  3. Click Device Settings, all RAID controllers in the system list in the Device Settings screen.
    To access the main menu for the controller, use the arrow keys or the mouse.
    System setup - Device settings - PERC selection |

    PERC HII main menu 
     
Note: For more information in all the options, click Help that is available on the upper right corner of the browser screen. Help information for individual option menus can also be viewed by scrolling down on each option.

Assign a global hot spare

To assign a global hot spare from the HII Configuration Utility, perform the following steps:   

Note: The utility allows only disks of the same disk technology and of equal or greater size to be selected as dedicated hot spare.
  1. Enter the Dell PERC 10 Configuration Utility. See Going to Dell PERC 10 configuration utility. 
  2. Click Main Menu > Physical Disk Management. The list of hard drives is displayed.
    PERC controller disk management selection 
     
  3. Select the hard drive.
    Physical disk management in PERC HII 
     
  4. From the Operations drop-down menu, select Assign Global Hot Spare.
    Hotspare selection list in PERC HII physical disk management 
     
  5. Click Go. A screen is displayed asking if you are sure you want to perform the operation.
    Applying changes 
     
  6. Select the Confirm option.
  7. Click Yes. The global hot spare disk is created successfully.
    confirmation 
     
  8. You can check the status of the hard drive.
    new status hot spare 
     

Assigning dedicated hot spare

To assign a dedicated hot spare from the HII Configuration Utility, perform the following steps:

Note: The utility allows only disks of the same disk technology and of equal or greater size to be selected as dedicated hot spare.
  1. Enter the Dell PERC 10 Configuration Utility. See Going to Dell PERC 10 configuration utility. 
  2. Click Main Menu > Physical Disk Management. The list of hard drives is displayed.
    physical disk management 
     
  3. Select the hard drive.
    disk selection 
     
  4. From the Operations drop-down menu, select Assign Dedicated Hot Spare
    Assign hotspare 
     
  5. Click Go. Select the associate virtual to the dedicated hot spare.
    dedicated hotspare 
     
  6. Select the Confirm option. 
  7. Click Yes. The dedicated hot spare disk is created successfully.
    confirmation 
     
  8. You can check the status of the hard drive.
    status confirmation 
     

Unassign a hot spare

To unassign a hot spare from the HII Configuration Utility, perform the following steps:   

  1. Enter the Dell PERC 10 Configuration Utility. See Going to Dell PERC 10 configuration utility. 

  2. Click Main Menu > Physical Disk Management, and the list of hard drives is displayed.
    physical disk management 
     
  3. Select the hot spare you want to unassign.
  4. From the Operations drop-down menu, select Unassign Hot Spare.
    Hotspare unassignment  
     
  5. Select the Confirm option. 
  6. Click Yes. The hot spare disk is unassigned successfully.
    confirmation 
     
  7. You can check the status of the hard drive.
    status confirmation 
     
Note: Try to use hard drives of the same capacity in a specific virtual disk. If you use hard drives with different capacities in a virtual disk, all hard drives in the virtual disk are treated as if they have the capacity of the smallest hard drive.

추가 정보

How To Configure Hot Spare Drive On It PowerEdge Server

Duration: 00:03:13 (hh:mm:ss)
When available, closed caption (subtitles) language settings can be chosen using the CC icon on this video player.

 

해당 제품

PowerEdge RAID Controller H345, PowerEdge RAID Controller H745, PowerEdge RAID Controller H745P MX, PowerEdge RAID Controller H740P, PowerEdge RAID Controller H840

제품

Fixed Workstations, OEMR R340, OEMR R440, OEMR R540, OEMR R640, OEMR XL R640, OEMR R740, OEMR XL R740, OEMR R740xd, OEMR R740xd2, OEMR R840, OEMR R940, OEMR R940xa, OEMR XL R240, PowerEdge C6420, PowerEdge MX740C, PowerEdge MX840C, PowerEdge R240 , PowerEdge R250, PowerEdge R340, PowerEdge R350, PowerEdge R440, PowerEdge R450, PowerEdge R540, PowerEdge R550, PowerEdge R640, PowerEdge R6415, PowerEdge R650, PowerEdge R650xs, PowerEdge R6515, PowerEdge R6525, PowerEdge R740, PowerEdge R740XD, PowerEdge R740XD2, PowerEdge R7415, PowerEdge R7425, PowerEdge R750, PowerEdge R750XA, PowerEdge R750xs, PowerEdge R7515, PowerEdge R7525, PowerEdge R840, PowerEdge R940, PowerEdge R940xa, PowerEdge T140, PowerEdge T150, PowerEdge T340, PowerEdge T350, PowerEdge T440, PowerEdge T550, PowerEdge T640 ...
문서 속성
문서 번호: 000177797
문서 유형: How To
마지막 수정 시간: 31 1월 2025
버전:  11
다른 Dell 사용자에게 질문에 대한 답변 찾기
지원 서비스
디바이스에 지원 서비스가 적용되는지 확인하십시오.