This article provides the information of how to assign or unassign a global dedicated hot spare for a physical disk drive.
A dedicated hot spare is assigned to only one virtual disk on the controller.
A Global hot spare is assigned to all virtual disks on the controller.
Dell PowerEdge RAID Controller 10 (PERC H740P, PERC H745P MX, PERC H840) supports this feature. See the Dell PowerEdge RAID Controller manual for more information.
Perform the following steps to boot to the HII configuration utility:
Turn on the system.
While the system startup, press F2 to enter System Setup.
Click Device Settings, all RAID controllers in the system list in the Device Settings screen. To access the main menu for the controller, use the arrow keys or the mouse. |
Note: For more information in all the options, click Help that is available on the upper right corner of the browser screen. Help information for individual option menus can also be viewed by scrolling down on each option.
Click Main Menu > Physical Disk Management, and the list of physical disks is displayed.
Select the hot spare you want to unassign.
From the Operations drop-down menu, select Unassign Hot Spare.
Select the Confirm option.
Click Yes. The hot spare disk is unassigned successfully.
You can check the status of the physical disk.
Note: Try to use physical disks of the same capacity in a specific virtual disk. If you use physical disks with different capacities in a virtual disk, all physical disks in the virtual disk are treated as if they have the capacity of the smallest physical disk.
원인
See above
해결
See above
추가 정보
Related Resources Here are some recommended resources related to this topic that might be of interest: