메인 콘텐츠로 이동
  • 빠르고 간편하게 주문
  • 주문 보기 및 배송 상태 추적
  • 제품 목록을 생성 및 액세스

How to create a RAID with Intel, PERC and LSI Controllers

요약: How to create a RAID with Intel Rapid Storage controller, PERC and LSI MegaRAID Controllers.

이 문서는 다음에 적용됩니다. 이 문서는 다음에 적용되지 않습니다. 이 문서는 특정 제품과 관련이 없습니다. 모든 제품 버전이 이 문서에 나와 있는 것은 아닙니다.

지침

Table of Contents

Caution: Keep in mind that a RAID is not a Backup! Dell is NOT responsible for any data loss which can occur on the configuration process of a RAID. Ensure that a backup is available before you create a new RAID or reconfigure an existing one.

How to create a RAID

RAID controllers which are available on Dell computers are not only different in performance and available connectors, but also in how to configure them. Because of that, we explain the process of setting up a new RAID for all three kinds of controllers separately.

Intel Rapid Storage Technology

Before you can use the Intel Rapid Storage Technology to configure your RAID, you must set the SATA Operations to RAID On in the System Setup.

After the POST (Dell Logo) is complete, you see an overview of all hard disk drives and RAID volumes. The shortcut Ctrl + i brings up the Controller Setup.

Boot Screen after POST
Note: On our latest Systems, you can find the entry Device Configuration in the boot menu (F12 while Dell Logo is shown). This leads you directly into the Controller Setup. 

In the main menu, you can also see an overview of all available drives and RAIDs.

Main Menu Intel Rapid Storage
Navigate with the arrow keys to Create RAID Volume and confirm with the Enter-Key.

Create RAID Volume Screen
In the Create Volume Menu you can choose a Name for the RAID, set the RAID Level, select the Hard Drives you want to use, set the Strip Size and determine the Capacity of the RAID.

Create Volume Confirmation
After the volume is created, it is available for installing the operating system.

Main Menu after Volume is created
Note: Keep in mind that you have to integrate the drivers for the RAID controller before you can select the RAID Volume during the installation of the operating system. This does not apply to all available operating systems. 

Back to Top


 

PERC

When you built in the PERC card and all drives are connected, you can use the RAID functionality of the controller card.

After the POST is complete, the controller BIOS will be initialized. Use the shortcut Ctrl + R to enter the configuration menu.

Boot screen after POST
Note: On our latest Systems, you can find the entry Device Configuration in the boot menu (F12 while Dell Logo is shown). This leads you directly into the controller setup. 

As seen at the bottom of the screen, you have to use the keyboard for navigation in the setup. In the VD Mgmt screen, you see an overview of all RAID volumes present.

PERC VD Management
Press F2 to open the operations menu and select Create new VD. At the following screen, you can configure the new RAID Volume. Choose the RAID-Level, select the Hard Drives you want to use and set the RAID Capacity. Then also set a name for the RAID Volume.

PERC creating the VD
In the PERC you can also set some Advanced Settings like stripe size:

Read Policy

  • No Read Ahead: The used data is not puffered.
  • Read Ahead: Puffering of frequently used data for faster accessibility.
  • Adaptive Read Ahead: The controller automatically switches between Read Ahead active or inactive.

 

Write Policy

  • Write Through: The write process is marked as complete when all data is written on the hard drive.
  • Write Back: The write process is marked as complete when the data is written to the controller's cache (a battery connected to the PERC is needed).

 

Further Options

  • Force WB with no battery: Is forcing Write Back without a battery connected. 
Caution: If the system is shut off while data is written in the cache and not on the hard drive, this data is lost and the RAID may be destroyed.
  • Initialize: A new created RAID Volume has to be initialized. This can also be done in the VD Management menu.
  • Configure HotSpare: Here you can select a hot spare drive to use if one drive of your RAID volume fails. (Not available for RAID 0)

 

After the RAID is created, you can initialize the volume in the VD Management.

PERC initialize VD
Note: Keep in mind that a new created RAID Volume has to be initialized before it is usable. 

Back to Top


 

LSI MegaRAID

Before you can use the LSI MegaRAID Controller, you have to deactivate the onboard Controller in the System Setup.

System Setup (BIOS)
After that you can enter the controller in the boot menu. Select the Device Configuration option.

Boot Menu
Select the Configuration Management.

LSI Main Menu
Now you can select Create Virtual Drive.

LSI Configuration Management
Here you can set the RAID-Level and choose the Hard Drives you want to use for the RAID in the Select Drives option.

LSI Create VD Menu
At the Select Drives menu, set which drive types should be shown to select in the Select Media Type option. After that, you can select the drives you want to use from the list below.

LSI physical Disk selection
In the last step, you choose a name for the RAID Volume, the size of the RAID and set the Read/Write Policies. Then you choose if the Volume should be initialized in the background while using the controller setup.

LSI Create VD Menu
Read Policy

  • No Read Ahead: The used data is not puffered.
  • Read Ahead: Puffering of frequently used data for faster accessibility.
  • Adaptive Read Ahead: The controller automatically switches between Read Ahead active or inactive.

 

Write Policy

  • Write Through: The write process is marked as complete when all data is written on the hard drive.
  • Write Back: The write process is marked as complete when the data is written to the controller's cache (a battery connected to the PERC is needed).
 
Note: Keep in mind, that a new created RAID Volume has to be initialized before it is usable.

Back to Top


 

Troubleshooting RAID Problems

While using RAID Technology errors can occur, these are often wrong configurations, defective disks, or controllers. We show you how to solve the most common problems regarding RAID.

RAID degraded error

A RAID is degraded if one or more drives of this RAID fail. If this happens on a RAID 0, the volume and all Data will be lost if the Hard Drives are the source of the issue. If the Controller is the cause of the problem, then the RAID should not be available and a simple reseat or replace of the controller will solve the issue.

Intel Rapid Storage

Intel RAID degraded
PERC

PERC RAID degraded
LSI MegaRAID

LSI RAID degraded
Back to Top


 

How to rebuild a RAID

When the defective hard disk is replaced, you can start to repair your raid. To do so, open the Configuration Menu of your RAID-Controller. 

Note: With a RAID 0, a rebuild is not possible because all data is lost when a hard disk fails.

 
Intel Rapid Storage

For the Intel Rapid Storage Technology, it is enough to open up the Controller Setup. There you are prompted with a message that a new hard disk is available to start the rebuild of the degraded RAID.

Intel new Drive Message
The rebuild starts when your operating system is loaded.

Intel Main Menu rebuilding
Back to Top


 

PERC

For the PERC, you have to select the hard drive and open the operations menu with F2 and select Make Global HS.

PERC PD Management
After that, the rebuild will start automatically.

PERC VD Management
Back to Top


 

LSI MegaRAID

In the detailed view, you can go to View Associated Drives and select the new hard drive for the rebuild.

LSI RAID detailed view
Set the specific hard drive as enabled.

LSI associated drives
You can see in the Drive Management that the status of the hard drive is set to Rebuilding.

LSI Drive Management
Back to Top


 

What to do if a Foreign Config is present

Replacement hard drives can be configured in a RAID before and still have the configuration information stored in the drives cache. The RAID Controller will notice this configuration and needs advice what to do with this configuration. 

Note: This only applies to LSI MegaRAID and PERC. The Intel controller will always use the configuration which is saved in the controller itself.

PERC

In the controller menu is shown that there is a foreign config present.

Physical Disk Management
You can Clear or Import the configuration in the Foreign View menu.

Foreign View
Note: This imports the configuration from the drive and delete the config of the controller! Use this only if you want to use a RAID config from a different system or replaced the controller. Clear: This deletes the configuration of the specific hard drive. After that you can use the drive for creating a new raid or rebuilding an existing one.

Back to Top


 

LSI MegaRAID

In Drives Management you can see if a physical disk already got a RAID configuration from another controller.

Drives Management
In the Configuration Management menu, you find a new option listed as Manage Foreign Configuration.

Configuration Management
Use the Preview Foreign Configuration to check the details of the foreign configurations.

Manage Foreign Configuration
In this detailed view, you can import (Import Foreign Configuration) or delete (Clear Foreign Configuration) the unknown configuration from the hard drive.

Foreign Configuration detailed view
Note: This imports the configuration from the drive and delete the config of the controller! Use this only if you want to use a RAID config from a different system or replaced the controller. Clear: This deletes the configuration of the specific hard drive. After that you can use the drive for creating a new raid or rebuilding an existing one.

If you want to clear the configuration you have to confirm this separately.

confirmation screen
Back to Top

해당 제품

Desktops & All-in-Ones, Laptops
문서 속성
문서 번호: 000148741
문서 유형: How To
마지막 수정 시간: 16 7월 2024
버전:  5
다른 Dell 사용자에게 질문에 대한 답변 찾기
지원 서비스
디바이스에 지원 서비스가 적용되는지 확인하십시오.