메인 콘텐츠로 이동

PowerEdge: How to remove or replace a Power Supply Unit (PSU)

요약: Step-by-step instructions to remove and replace the Power Supply Unit (PSU).

이 문서는 다음에 적용됩니다. 이 문서는 다음에 적용되지 않습니다. 이 문서는 특정 제품과 관련이 없습니다. 모든 제품 버전이 이 문서에 나와 있는 것은 아닙니다.

지침


Replacing a power supply unit is a simple action. If the server has two power supplies configured in redundant mode, which is the default setting, you can remove one without shutting down the server.
The remaining power supply continues to provide the power to the server. In general, all components with an amber removal tool can be unplugged while the server is powered on.
 
Warning: The system requires at least one power supply for normal operation. On power-redundant systems, remove and replace only one power supply at a time in a system that is powered on.
 
  1. Disconnect the power cable from the power source and from the power supply unit that you intend to remove, and then remove the cable from the strap.
  2. Press the release latch and slide the power supply unit out of the chassis.
Image of a standard server power supply and indicators for the release latch
1.  Release latch
2. Power supply unit cable connector
3. Power supply unit
4. Connector
5. Power supply unit handle

To insert the new power supply, insert the block in the slot. This operation can be done while the server is powered on.

추가 정보

Removing a PowerEdge Power Supply Unit

Duration: 00:00:45
When available, closed caption (subtitles) language settings can be chosen using the CC icon on this video player.

해당 제품

PowerEdge C6400, PowerEdge C6600, PowerEdge R240, PowerEdge R250, PowerEdge R260, PowerEdge R340, PowerEdge R350, PowerEdge R360, PowerEdge R440, PowerEdge R450, PowerEdge R470, PowerEdge R540, PowerEdge R550, PowerEdge R640, PowerEdge R6415 , PowerEdge R650, PowerEdge R650xs, PowerEdge R6515, PowerEdge R6525, PowerEdge R660, PowerEdge R660xs, PowerEdge R6615, PowerEdge R6625, PowerEdge R670, PowerEdge R740, PowerEdge R740XD, PowerEdge R740XD2, PowerEdge R7415, PowerEdge R7425, PowerEdge R750, PowerEdge R750XA, PowerEdge R750xs, PowerEdge R7515, PowerEdge R7525, PowerEdge R760, PowerEdge R760XA, PowerEdge R760xd2, PowerEdge R760xs, PowerEdge R7615, PowerEdge R7625, PowerEdge R770, PowerEdge R7715, PowerEdge R7725, PowerEdge R840, PowerEdge R860, PowerEdge R940, PowerEdge R940xa, PowerEdge R960, PowerEdge T340, PowerEdge T350, PowerEdge T360, PowerEdge T440, PowerEdge T550, PowerEdge T560, PowerEdge T640 ...
문서 속성
문서 번호: 000141313
문서 유형: How To
마지막 수정 시간: 22 2월 2025
버전:  13
다른 Dell 사용자에게 질문에 대한 답변 찾기
지원 서비스
디바이스에 지원 서비스가 적용되는지 확인하십시오.