How to generate enclosure logs for PowerEdge M1000e, VRTX and FX2 enclosures

요약: Use PuTTY to collect the logs from the CMC of a M1000e, VRTX and FX2 chassis. These logs can be useful to troubleshoot a failure occurring on the CMC, on the chassis or directly on a blade. ...

이 문서는 다음에 적용됩니다.   이 문서는 다음에 적용되지 않습니다. 

증상

This article applies to any modular enclosure using a Chassis Management Controller called CMC: M1000e, VRTX, FX2.



It explains how to use PuTTy to collect support logs from the CMC. These logs can be useful to troubleshoot an issue occurring at the chassis, blade, or console level.
 

원인


Commands

RACDUMP

The command racdump may be all that you need to troubleshoot most issues.

 

DUMPLOGS

The command dumplogs is used by engineering and is required when escalating. To avoid having to gather additional logs later, it is suggested to gather racdump and dumplogs together.

Note: If you run dumplogs, it can take about a minute to scroll through the screen, so ensure that logging is enabled first. The file is a large text file.

해결


Run Commands

It is recommended to use  PuTTY to connect to the controller and gather logs.
 

  1. Download PuTTy
  2. Open PuTTY and enable logging (Figure 1)

    QNA25813_en_US__11248872983197.putty01
    Figure 1: Specify Output

     
  3. Under Session, specify the CMC hostname or CMC IP address and click open (Figure 1)

    QNA25813_en_US__21248873094357.putty02
    Figure 2: Specify Target System

     
  4. Type the Command that you want to run. Examples:
    racdump
    dumplogs
    getversion


    Supported commands are documented in the Chassis Management Controllers. For a complete report logs the following commands should be launched:

    - getsysinfo
    - getioinfo
    - getdcinfo
    - getpbinfo
    - getsel
    - getraclog
    - racdump
    - dumplogs

     
  5. To end the session type the command: exit

    QNA25813_en_US__31248873204033.putty03
    Figure 3: PuTTY CLI 
     
  6. The created logs can now be analyzed.

해당 제품

Dell Chassis Management Controller Version 2.30 For Dell PowerEdge FX2, Dell Chassis Management Controller Version 3.20 For Dell PowerEdge VRTX, Dell Chassis Management Controller Version 3.21 For Dell PowerEdge VRTX , Dell Chassis Management Controller Version 3.30 For Dell PowerEdge VRTX, Dell Chassis Management Controller Version 6.0 for Dell PowerEdge M1000e, Dell Chassis Management Controller Version 6.10 For Dell PowerEdge M1000e, Dell Chassis Management Controller Version 6.20 For Dell PowerEdge M1000e, Dell Chassis Management Controller Version 6.21 For Dell PowerEdge M1000e ...