メイン コンテンツに進む
  • すばやく簡単にご注文が可能
  • 注文内容の表示、配送状況をトラック
  • 会員限定の特典や割引のご利用
  • 製品リストの作成とアクセスが可能

PowerScale: Cluster Becomes Inaccessible During a Parallel Firmware Upgrade

概要: During a parallel OneFS upgrade that includes the --fw-pkg switch, or a parallel firmware only upgrade containing PowerScale nodes (F200, F210, F600, F710, F900, or F910), the cluster becomes inaccessible. ...

この記事は次に適用されます:   この記事は次には適用されません: 

現象

During the upgrade, the cluster becomes inaccessible to end-users. The cluster indicates multiple nodes down and splits due to Read-Only (RO) status. Logs indicate that the nodes can no longer communicate with the iDRAC so they are being set RO. Filesystem operations may be suspended or aborted due to deadlocks, timeouts, or loss of quorum.

原因

During the upgrade process, if the iDRAC firmware version is being updated, the iDRAC reboots as part of the process. There is an approximately three minute window where the iDRAC is inaccessible. This prevents hardware health monitoring, so the node is set Read-Only until the iDRAC comes back online. The upgrade engine tracks the upgrade status in each neighborhood by disk pool reservations. When the node is set to RO during the iDRAC reboot, this cancels its existing disk pool reservation. Once the reservation is released, the upgrade engine initiates the upgrade on the next node in the neighborhood. This causes a progressively larger number of nodes to start upgrading until the cluster becomes wedged.

解決方法

Contact Dell Technical Support and quote this knowledge base article ID.

Until further notice, for clusters with Gen6.5 hardware, only use the --rolling switch when performing any upgrade that includes the Node Firmware Package. The parallel upgrade limitation is specific to when you are applying firmware. Command examples are:
# isi upgrade cluster start --parallel /ifs/data/OneFS_v9.5.0.7_LTS2023_V2_Install.isi (safe command as it does not include the node firmware package)

# isi upgrade firmware start --rolling --fw-pkg=/ifs/data/Isi_Fw_Package_v12.0.tar (safe command as you are doing a rolling upgrade)

# isi upgrade firmware start --parallel --fw-pkg=/ifs/data/Isi_Fw_Package_v12.0.tar (could induce DU as you are doing a firmware update with the parallel option)

# isi upgrade cluster start --parallel /ifs/data/OneFS_v9.5.0.7_LTS2023_V2_Install.isi --fw-pkg=/ifs/data/Isi_Fw_Package_v12.0.tar (could induce DU as you are including firmware in a parallel upgrade)

対象製品

PowerScale F200, PowerScale F600, PowerScale F900