文書番号: 000218471
Dette dokumentet beskriver hvordan du kontrollerer batterilevetiden på reservebatteriet (BBU) for generelle formål, eller du har mottatt en hendelse som ligner denne:
Warning battery: The battery backup unit in chassis XXXXXXXXXXXXXX slot 2 has indicated cell End Of Life. Replace the battery backup unit as soon as possible.
Forutsetning:
Klyngen må kjøre Health Check Framework 35 eller nyere og én av følgende versjoner av OneFS:
# isi healthcheck version HealthCheck definition version: 35.0.0
# isi healthcheck run battery_test_status -v Queued evaluation to run: battery_test_status20231011T1718
isi healthcheck list | grep battery_test_status20231011T1718 Completed - Pass - /ifs/.ifsvar/modules/health-check/results/evaluations/battery_test_status20231011T1718
# cat /ifs/.ifsvar/modules/health-check/results/evaluations/battery_test_status20231011T1718 {"checklist_id": "battery_test_status", "delivery": [], "id": "battery_test_status20231011T1718", "overrides": [], "parameters": {}, "start_time": 1697044712.9590354} {"name": "battery_test_status", "parameters": {}, "status": "OK", "value": 100, "details": ["Battery 1 has 0 most recent test failures, threshold is 3", "Battery 1 Permanent fault status is False", "Battery 1 Capacity Degradation: 137600 mAh, 13.1%"], "node": "1", "passed": true} {"name": "battery_test_status", "parameters": {}, "status": "OK", "value": 100, "details": ["Battery 1 has 0 most recent test failures, threshold is 3", "Battery 1 Permanent fault status is False", "Battery 1 Capacity Degradation: 136100 mAh, 12.96%"], "node": "2", "passed": true} {"name": "battery_test_status", "parameters": {}, "status": "OK", "value": 100, "details": ["Battery 1 has 0 most recent test failures, threshold is 3", "Battery 1 Permanent fault status is False", "Battery 1 Capacity Degradation: 136850 mAh, 13.03%"], "node": "3", "passed": true} {"name": "battery_test_status", "parameters": {}, "status": "OK", "value": 100, "details": ["Battery 1 has 0 most recent test failures, threshold is 3", "Battery 1 Permanent fault status is False", "Battery 1 Capacity Degradation: 136400 mAh, 12.99%"], "node": "4", "passed": true} {"result":"PASS"}
isi upgrade cluster firmware devices | egrep "mongoose|bcc"
Utdataene fra kommandoen ser slik ut:
# isi upgrade cluster firmware devices| egrep "mongoose|bcc" MLKbem_mongoose ePOST 02.40 1-4 EPbcc_infinity ePOST 02.40 5-8
BBU-fastvaren påvirker tiden det tar å gå fra 40 % degradering til 50 % nedbrytning.
Hvis BBU-firmwareversjonen er 1.20, vil det ta fire måneder før batteriet går fra 40 % til 50 % degradering.
Hvis BBU-fastvareversjonen er 2.20 eller høyere, bør det ta 12 måneder før batteriet går fra 40 % til 50 % degradering.
Hvis BBU-fastvare versjon 1.20 eller eldre er installert og ønsker å oppgradere til den nyeste støttede fastvaren, må du gjennomgå dette dokumentet først: Slik utfører du batteritesten før du oppgraderer til nodefastvarepakke 10.3.9 eller 11.6
Isilon A200, Isilon A2000, Isilon F800, Isilon F810, Isilon Gen6, Isilon H400, Isilon H500, Isilon H5600, Isilon H600