Windows Server: Microsoft Azure Stack HCI Cluster Deployment

概要: This article provides information and steps for deploying a Microsoft Azure Hyperconverged Infrastructure (HCI) S2D cluster documented in the "Microsoft HCI Solutions from Dell Technologies" Guide. ...

この記事は次に適用されます: この記事は次には適用されません: この記事は、特定の製品に関連付けられていません。 すべての製品パージョンがこの記事に記載されているわけではありません。

手順

The screenshot below depicts the environment of a two-node HCI Cluster on a switched network. The PowerShell information below was adapted for this configuration but is still useful with modification for Clusters with more nodes and a switchless network topology.

Diagram of Microsoft Azure Stack HCI two node cluster in a Windows Active Directory, switch network environment.

 
The script example and the installation process are found in the Microsoft HCI Solutions from Dell Technologies Deployment Guide. The script runs steps after the Cluster Nodes operating systems installed, added to an active directory domain, and a Cluster network is put into place.

Configuration Items:

  • Windows Feature Install: Hyper-V, Failover-Clustering, Data-Center-Bridging, BitLocker, FS-FileServer, RSAT-Clustering-PowerShell, FS-Data-Deduplication
  • Driver Update Check:  Check Support Matrix
  • Rename Cluster Nodes
  • Cluster Test validation
  • Create S2D Cluster
  • Enable Storage Spaces Direct
  • Set host "Management" network priority for live migration
  • Page file settings: Allow for Memory Dump space
  • Configure cluster witness
  • Spaces port timeout configuration

The script example below should be adapted for the environment where the HCI Cluster is being deployed. Server names, Cluster name, cluster share name, and IP information must be modified to meet the installation environment parameters. When copying the script text below to the intended deployment script, ensure NOT to wrap PowerShell text.

Windows Feature Install:

Install-WindowsFeature -Name Hyper-V, Failover-Clustering, Data-Center-Bridging, BitLocker, FS-FileServer, RSAT-Clustering-PowerShell, FS-Data-Deduplication -IncludeAllSubFeature
-IncludeManagementTools -verbose

Retrieve the list of driver versions:

Get-PnpDevice | Select-Object Name, @{l='DriverVersion';e={(Get-PnpDeviceProperty -InstanceId $_.InstanceId -KeyName 'DEVPKEY_Device_DriverVersion').Data}} -Unique |
Where-Object {($_.Name -like "*HBA*") -or ($_.Name -like "*mellanox*") -or ($_.Name -like "*Qlogic*") -or ($_.Name -like "*X710*") -or ($_.Name -like "*intel*") -or ($_.Name -like "*Broadcom*") -or ($_.Name -like "*marvell*") }

Assign the Cluster node name:

Rename-Computer -NewName CN01 -Restart

Cluster Test

Test-Cluster -Node CN01, CN02 –Include 'Storage Spaces Direct', 'Inventory', 'Network', 'System Configuration'

Find status of Storage Pool disks

Get-PhysicalDisk

Creating new S2D cluster

New-Cluster -Name S2DSystem -Node CN01, CN02 -StaticAddress 192.168.10.33 -NoStorage -IgnoreNetwork 172.16.103.0/24, 172.16.104.0/24 -Verbose

Enabling Storage Spaces Direct:

Enable-ClusterS2D -Verbose

Capturing results of previous commands

Get-ClusterS2D
Get-StoragePool
Get-StorageSubSystem -FriendlyName *Cluster* | Get-StorageHealthReport

Configure host management network at lower priority for live migration:

$clusterResourceType = Get-ClusterResourceType -Name 'Virtual Machine'
$hostNetworkID = Get-ClusterNetwork | Where-Object { $_.Address -eq ‘192.168.10.0’ } |
Select-Object -ExpandProperty ID
$otherNetworkID = (Get-ClusterNetwork).Where({$_.ID -ne $hostnetworkID}).ID
$newMigrationOrder = ($otherNetworkID + $hostNetworkID) -join ';'
Set-ClusterParameter -InputObject $clusterResourceType -Name MigrationNetworkOrder -Value
$newMigrationOrder
Set-VmHost -VirtualMachine MigrationPerformanceOption SMB

Page files settings to ensure that memory dump can be captured:

$blockCacheMB = (Get-Cluster).BlockCacheSize

$blockCacheMB = (Get-Cluster).BlockCacheSize
$pageFilePath = "C:\pagefile.sys"
$initialSize = [Math]::Round(51200 + $blockCacheMB)
$maximumSize = [Math]::Round(51200 + $blockCacheMB)
$system = Get-WmiObject -Class Win32_ComputerSystem -EnableAllPrivileges
if ($system.AutomaticManagedPagefile) {
$system.AutomaticManagedPagefile = $false
$system.Put()
}
$currentPageFile = Get-WmiObject -Class Win32_PageFileSetting
if ($currentPageFile.Name -eq $pageFilePath)
{
$currentPageFile.InitialSize = $InitialSize
$currentPageFile.MaximumSize = $MaximumSize
$currentPageFile.Put()
}else{
$currentPageFile.Delete()
Set-WmiInstance -Class Win32_PageFileSetting -Arguments @{Name=$pageFilePath;
InitialSize = $initialSize; MaximumSize = $maximumSize}
}
#Configure cluster witness. Active Directory Cluster Name Object must be given write access on file #share before running this step:
Set-ClusterQuorum -NodeAndFileShareMajority \\VDC01\ClusterQuorum

Disable Server Message Block (SMB) Signing; disabled by default with normal Windows Server installation.

Set-SmbServerConfiguration -RequireSecuritySignature $FALSE -force

Spaces port timeout configuration change:

Set-ItemProperty -Path HKLM:\SYSTEM\CurrentControlSet\Services\spaceport \Parameters -Name HwTimeout -Value 0x00002710 -Verbose Restart-Computer -Force

対象製品

Hyper-converged Systems, Microsoft Windows Server 2016, Microsoft Windows Server 2019, Microsoft Windows Server 2022

製品

PowerEdge FC640, PowerEdge M640, PowerEdge M640 (for PE VRTX), PowerEdge MX740C, PowerEdge MX750c, PowerEdge MX760c, PowerEdge MX840C, PowerEdge R250, PowerEdge R340, PowerEdge R350, PowerEdge R360, PowerEdge R440, PowerEdge R450, PowerEdge R540 , PowerEdge R550, PowerEdge R640, PowerEdge R6415, PowerEdge R650, PowerEdge R650xs, PowerEdge R6515, PowerEdge R6525, PowerEdge R660, PowerEdge R660xs, PowerEdge R6615, PowerEdge R6625, PowerEdge R740, PowerEdge R740XD, PowerEdge R740XD2, PowerEdge R7415, PowerEdge R7425, PowerEdge R750, PowerEdge R750XA, PowerEdge R750xs, PowerEdge R7515, PowerEdge R7525, PowerEdge R760, PowerEdge R760XA, PowerEdge R760xd2, PowerEdge R760xs, PowerEdge R7615, PowerEdge R7625, PowerEdge R840, PowerEdge R860, PowerEdge R940, PowerEdge R940xa, PowerEdge R960, PowerEdge T340, PowerEdge T350, PowerEdge T360, PowerEdge T440, PowerEdge T550, PowerEdge T560, PowerEdge T640 ...
文書のプロパティ
文書番号: 000201913
文書の種類: How To
最終更新: 10 12月 2024
バージョン:  9
質問に対する他のDellユーザーからの回答を見つける
サポート サービス
お使いのデバイスがサポート サービスの対象かどうかを確認してください。