メイン コンテンツに進む
  • すばやく簡単にご注文が可能
  • 注文内容の表示、配送状況をトラック
  • 会員限定の特典や割引のご利用
  • 製品リストの作成とアクセスが可能

ITDT-SE CLI for Windows: Use of ITDT to Update Tape Drives and Run Diagnostics

概要: This article explains how to use ITDT-SE (CLI) to upgrade firmware, perform diagnostics, and pull logs for Dell Support.

この記事は次に適用されます: この記事は次には適用されません: この記事は、特定の製品に関連付けられていません。 すべての製品パージョンがこの記事に記載されているわけではありません。

現象

This article provides information about ITDT-SE for Windows. ITDT-SE is used to pull log files (drive dumps) and perform other various functions such as eject media, run tape drive diagnostics, update firmware, and so forth.
 
Note: ITDT-DCR is end of life. The DCR version does not support LTO7 or newer generation tape drives.

原因

Not required

解決方法

Index:


Note: Backup software services may interfere with firmware updates, drive detection, and diagnostics. It is best to set the backup service to "disabled" then reboot the host and tape drive or library. This clears any reservations on the library or tape drives.
 

Installing ITDT-SE (CLI)

ITDT-SE does not have an installer, the installation is extracting files on to the user's machine. The extractor creates input, license, output, and script folders along with the ITDT executable, a readme, and two other files. No reboot is required.

ITDT-SE (CLI) can be found on Dell Support. Choose the PowerVault tape drive, auto loader, or library you are working with. ITDT-SE (CLI) is found in the Tape Automation Category.

  1. Once downloaded, right click to run as administrator

ITDT-SE Tape Automation

  1. The default location is C:\\Dell\Drivers\….
Tape Automation location
  1. Two files are extracted

Names of files extracted

  1. In this instance, a Windows host is used. Right-click the Windows version and run as administrator

Select host type and run as administrator

  1. Go to the ITDT folder that is created. To start ITDT, right click the ITDT application and run as administrator

Right click folder and run as administrator


Note: When first extracted, the output and input folder may not be created. The two folders are created once the ITDT application is run.
 

Tape Drive Log

If a tape drive is failing during backups or while running diagnostics, gathering a drive dump from the tape drive helps determine if the drive must be replaced. If media is suspect, it is beneficial to gather drive dumps from all tape drives in a tape library. When the drive dump is generated, three files are created in the "output" folder. The files are "A," "B" and "BLZ." All three files can be useful in determining drive issues.
 
  1. Start the ITDT-SE application by right clicking ITDT found in the ITDT folder
  2. The first time ITDT-SE is run, the License information is presented
  3. Press I on the last page to agree
  4. This brings up the Main Menu page
  5. Press [S] to scan for devices
Start ITDT-SE
  1. Select the drive that you want to gather the Dump
  2. Press [D] to generate the Dump files
Choose the drives from the list

Generate the dump files
  1. Once complete, Dump files are located in the Output folder where ITDT was extracted
  2. Press [R] to return to the device list. Select the next tape drive or Press [Q] to quit
Device list
  1. Dump files are generated. Zip all three files for Dell Support to review.
Zip files for Dell Support
 

Tape Drive Diagnostics

There are several different diagnostics that can be performed using ITDT-SE, ensure you run the appropriate diagnostic.
  • If the tape drive does not start writing to the media, a system test would be useful. The system test is a short diagnostic test.
  •  When trying to determine if that tape drive is having an issue with a read or write head vs media, one of the best ways to help is to run a full write test with a brand-new tape.
  • The full write test exercises all write heads, and is a longer diagnostic test. Once diagnostics are completed, it generates a drive dump from the drive, for whichever diagnostic test is run.
  • A stand Alone tape drive requires a tape inserted into the drive to run tests. Tape Libraries require a tape in the I/O station.
Note: Use a blank or scratch tape when running diagnostics as some tests overwrite the data.
 
  1. Open ITDT-SE (CLI)
  2. Select the drive to be tested
  3. Select the diagnostic option
Select the drive and the diagnostic option
  1. Select [O] for other functions
Select O for other options
  1. Select [W] for Full Write test
  2. Select the block size
Select block size
  1. Choose what type of data to test. Incompressible data runs at the Native speed of the tape drive.  
Choose what type of data to test
 
Tape capacity
  1. Once the diagnostic is complete, ITDT-SE either Passes or Fails
  2. Logs are generated in the Output folder where ITDT-SE was extracted
 

Tape Drive Firmware Update

After updating the firmware on a tape drive, the host must be rebooted before running diagnostics or backup jobs.
  1. Download the appropriate firmware for the tape drive that is being updated from Dell Support Site
  2. Extract the firmware, the default location is C:\Dell\Drivers\.... Write down the folder location when files are extracted
  3. Copy the firmware file to the Input folder where ITDT-SE was extracted
Note: There may be separate firmware files for Full Height and Half Height drives as well as SAS and FC drives.
 

   Different files for different hights

  1. Open ITDT-SE (CLI)
  2. Select tape drive to be upgraded

Select tape drive to be upgraded

  1. Press [F] for firmware update
  2. Select the firmware file then Press [C] to continue

Select firmware file

  1. The Directory and Firmware file is listed. Press [S] to start firmware update

Press [S] to start firmware update

  1. Once complete, the Status should be Passed

Status should be Passed

  1. Press [R] to return and select next drive to be update
  2. Once all drives are complete, the server must be rebooted before testing or running backup jobs

 

Eject Tape Media

The Eject Tape Media function in ITDT-SE may be used if a tape does not eject using the backup software. To clear any reservation on the tape drive by the backup software, set all backup services to disable, reboot server, and tape device.
 

Note: Mid-tape recovery could take up to 10 minutes to complete. During the recovery, the Single Character Display (SCD) flashes one segment at a time to complete one figure-eight motion, then flashes the number 9, then flashes one segment at a time to complete one figure-eight motion, then flashes the number 8. This continues until the number 1 flashes and the drive completes recovery. You can eject the tape cartridge once the count down has ended by pressing the eject button.
 
Note: The normal eject process can take 5 minutes or longer depending on the amount of tape spooled into the drive. The activity LED on the tape drive stops flashing once activity has stopped.
 
  1. Open ITDT-SE
  2. Select the drive that has media loaded
  3. Select [J] to eject media

Select the drive with media

  1. Result is Passed if the tape ejected



Tape Usage

The Tape Usage function retrieves statistical data and error counters from a tape cartridge.


Note: Tape Usage does not create a log file.
 
  1. Open ITDT-SE
  2. Select a drive that has media loaded
  3. Select [O] for other options
  4. Select [U] for Tape Usage

Tape usage from media drive

対象製品

Dell EMC ML3, PowerVault 136T LTO/SDLT (Tape Library), PowerVault LTO4-120HH, PowerVault LTO5-140, Powervault LTO6, PowerVault LTO7, PowerVault LTO8
文書のプロパティ
文書番号: 000145038
文書の種類: Solution
最終更新: 15 3月 2024
バージョン:  6
質問に対する他のDellユーザーからの回答を見つける
サポート サービス
お使いのデバイスがサポート サービスの対象かどうかを確認してください。