PowerEdge: I2C Messages in the PERC H310, H710, H810 Controller Logs

この記事は自動翻訳されたものである可能性があります。品質に関するフィードバックがある場合は、このページの下部にあるフォームを使用してお知らせください。

文書の内容


現象

If you receive I2C messages in the TTY debug logs of the series 8 RAID controllers that were introduced with 12G servers, this might not be caused by a hardware failure.

 

There are three I2C buses given:

  1. SEP (chip on the backplain to recognize if a device is present on PHY’s and control the LED pattern)
  2. Thermal sensor
  3. CEM (Communicate Embedded Management for iDRAC).

 

If the H310 busy to do data transactions, specially when both JBOD and VD access simultaneously, the I2C interrupts every 5 seconds from CEM (no functional impact here). As it is being missed, this is causing those events.  

During each boot up, the iDRAC has to communicate with the RAID controller to do inventory, status, and other functions. Communication between the RAID controller and the iDRAC is done via a bus called I2C. 

Several messages were put in the RAID controller log during development to assist in resolving issues but many of the messages were not removed at the end.

 

Here is a sample of what will typically be seen:

09/04/12 18:55:37: I2C 1 reset!

09/04/12 18:55:42: I2C 1 reset!

09/04/12 18:55:42: I2C 1 reset!

09/04/12 18:55:43: I2C 1 reset!

09/07/12 20:42:46: One Wire Device detected fd000002aa470533

09/07/12 20:42:46: EepromInit: Family=33, SN=0547aa020000

09/07/12 20:42:46: One Wire Device detected fd000002aa470533

09/07/12 20:42:46: One Wire Device detected fd000002aa470533

09/07/12 16:00:34: ds1961s_ReadMemoryAuthenticated: EEprom CRC error in Reading AUTHENTICATED data

 

Given the nature of I2C this can potentially lead to thousands of TTY log entries around I2C device detection and negotiation.

These messages are innocuous and don't indicate that the RAID controller or the iDRAC is/are malfunctioning. No hardware has to be replaced based on the observance of these messages.

These TTY Log messages are filtered by newer firmwares of the PERC 8 Series controllers, starting with revision 20.12.1-0002 , which improves (reduces) I2C messaging in TTY log.

文書のプロパティ


影響を受ける製品

Servers, PowerEdge, PowerVault

最後に公開された日付

21 2月 2021

バージョン

3

文書の種類

Solution