メイン コンテンツに進む

PowerEdge: How to replace vSAN capacity disk

概要: This article provides how to replace vSAN capacity disk. In the vSAN environment using SSD and hard disk drives together, the SSD used as the cache memory is called the Cache Disk, the hard drive used as the data space is called the Capacity Disk. ...

この記事は次に適用されます: この記事は次には適用されません: この記事は、特定の製品に関連付けられていません。 すべての製品パージョンがこの記事に記載されているわけではありません。

手順

Note: This article is for replacing the capacity disk. How to replace the cache disk is different.
Note: If the cache disk and/or capacity disk is the minimum configuration or deduplication/compression is configured, the procedure after deleting the disk is different from this article.


https://docs.vmware.com/jp/VMware-vSphere/7.0/com.vmware.vsphere.vsan.doc/GUID-2285B446-46BF-429C-A1E7-BEE276ED40F7.htmlThis hyperlink is taking you to a website outside of Dell Technologies.

 


How To Replace The Capacity Disk:

As an example, this article proceeds with the situation where the second capacity disk has a failure in the configuration of one cache disk and two capacity disks.

 

  1. Switch to the maintenance mode from the Actions drop-down menu at the top of the vSphere Web Client.
    It is recommended to switch to the maintenance mode before the replacement as long as there is any specific reason.
    For more details of switching to the maintenance mode and its types, please refer to the Place a Member of vSAN Cluster in Maintenance ModeThis hyperlink is taking you to a website outside of Dell Technologies..

    vcenter inventory list showing VSAN cluster and action button 
    vcenter host action menu with maintence mode selected 

  2. Delete the applicable hard drive from the Configure menu.
    After a while, that disk will not be displayed.

    Note: The following migration option must be selected when deleting the applicable disk.

    For more details, please refer to the Remove Disk Groups or Devices from vSANThis hyperlink is taking you to a website outside of Dell Technologies..
    • Save all data to another host.
    • Verify the ability to access the data from another host.
    • Do not save the data.

    vcenter inventory list with VSAN cluster selected and configure tab 
    Disk Management option under VSAN section in the Cluster Configure section 
    vSAN Cluster Disk Management disk selection 

  3. Physically replace the applicable disk.

  4. Click the ADD DISKS.
    Selecting Add disks button from the Disk Management section of the VSAN cluster 

  5. Select the newly replaced disk and click ADD.
    Add Capacity disks wizard to select disks to add 

  6. Verify that the capacity is correctly recognized on the vSphere Web Client recognize, release the maintenance mode.

  7. Since the alert remains, delete it manually.

 
 

対象製品

VMware ESXi 6.7.X, VMware ESXi 7.x, VMware ESXi 8.x, VMware VSAN

製品

PowerEdge C6420, PowerEdge C6520, PowerEdge C6525, PowerEdge C6615, PowerEdge C6620, PowerEdge M640 (for PE VRTX), PowerEdge MX740C, PowerEdge MX750c, PowerEdge MX760c, PowerEdge MX840C, PowerEdge R440, PowerEdge R450, PowerEdge R540, PowerEdge R550 , PowerEdge R640, PowerEdge R6415, PowerEdge R650, PowerEdge R650xs, PowerEdge R6515, PowerEdge R6525, PowerEdge R660, PowerEdge R660xs, PowerEdge R6615, PowerEdge R6625, PowerEdge R740, PowerEdge R740XD, PowerEdge R740XD2, PowerEdge R7415, PowerEdge R7425, PowerEdge R750, PowerEdge R750XA, PowerEdge R750xs, PowerEdge R7515, PowerEdge R7525, PowerEdge R760, PowerEdge R760XA, PowerEdge R760xd2, PowerEdge R760xs, PowerEdge R7615, PowerEdge R7625, PowerEdge R840, PowerEdge R860, PowerEdge R940, PowerEdge R940xa, PowerEdge R960, PowerEdge T350, PowerEdge T360, PowerEdge T440, PowerEdge T550, PowerEdge T560, PowerEdge T640, PowerEdge XE2420, PowerEdge XE7420, PowerEdge XE7440, Dell EMC vSAN C6420 Ready Node, Dell EMC vSAN MX740c Ready Node, Dell EMC vSAN MX750c Ready Node, Dell vSAN Ready Node MX760c, Dell EMC vSAN R440 Ready Node, Dell EMC vSAN R640 Ready Node, Dell EMC vSAN R6415 Ready Node, Dell EMC vSAN R650 Ready Node, Dell EMC vSAN R6515 Ready Node, Dell EMC vSAN R660 Ready Node, Dell vSAN R6615 Ready Node, Dell EMC vSAN R740 Ready Node, Dell EMC vSAN R740xd Ready Node, Dell EMC vSAN R750 Ready Node, Dell EMC vSAN R7515 Ready Node, Dell EMC vSAN R760 Ready Node, Dell vSAN R7615 Ready Node, Dell vSAN Ready Node R7625, Dell EMC vSAN R840 Ready Node, Dell EMC vSAN T350 Ready Node ...
文書のプロパティ
文書番号: 000122008
文書の種類: How To
最終更新: 12 12月 2024
バージョン:  7
質問に対する他のDellユーザーからの回答を見つける
サポート サービス
お使いのデバイスがサポート サービスの対象かどうかを確認してください。