概要:On the PowerEdge FX2/FX2s chassis, there is not a control panel to set the chassis IP. This article explains how to set either a static or DHCP IP address using various methods.
On the FX2 and FX2s chassis, there is not a control panel to set the chassis IP. This article explains how to set either a Static or DHCP IP address using various methods.
In order to use this method the customer will need to connect to the Network Port on the CMC and also change their network settings to be the same as the network on the CMC.
IP Address: 192.168.0.x
NetMask: 255.255.255.0
Gateway: 192.168.0.1
To set the IP via the CMC WebGUI:
Open a Web Browser and Navigate to 192.168.0.120
Log-in using the default credentials:
User: "root"
Password: "calvin"
Once logged in, navigate to: Chassis Overview >> Network Modify the feilds below:
3. Set the CMC IP address via the Sled HII
Connect external monitor and keyboard to the chassis KVM.
Set Chassis KVM to the sled you want to use.
Power the sled.
Enter BIOS Setup by pressing <F2 - System Setup> when the post screen indicates.
Once in BIOS Setup, select <iDRAC Settings>.
Scroll down and select <CMC Network>.
Modfify the settings below in order to change the IP Address, Gateway or Netmask or to enable DHCP on the system.
To verify IP information for the system, Navigate to <System Setup> >> iDRAC Settings >> System Summary