Storage Center Alert: How to Troubleshoot Conservation Mode

この記事は次に適用されます:   この記事は次には適用されません: 

手順

Storage Center has entered Conservation Mode because to remaining free space is critically low.   No new volumes can be created.  Storage Center will begin to aggressively expire replays.    Immediate action is necessary to avoid entering Emergency Mode, which halts all write IO to Storage Center until sufficient space is available.

To resolve conservation mode, you must reclaim consumed space or add more capacity.  After Conservation Mode has been resolved, review the system capacity requirements and consider adding disk space.
 
Do not change the system- wide RAID level if the Storage Center is in Conservation Mode. Although it would seem logical that changing the RAID level from fewer drives to more drives would free space, the Storage Center needs additional space to hold data before restriping it. If you try to change the system- wide RAID level from five or six drives to nine or ten drives, you will run out of free space sooner.

Steps to Perform: 
To reclaim consumed space, perform each step and wait a few minutes before reassessing available space.

  1. Check the Recycle Bin and empty if applicable.
  2. Identify and expire Snapshotsthat are not necessary.
  3. Delete unnecessary volumes and empty Recycle Bin.
  4. Run whitespace recovery on hosts where applicable.

対象製品

Entry Level & Midrange, Compellent (SC, SCv & FS Series), Dell Compellent SC4020, Dell Storage SC8000, Dell Compellent Series 40, Dell Storage SCv2000, Dell Storage SCv2020, Dell Storage SCv2080, Dell Storage SC5020, Dell Storage SC7020 , Dell Storage SC9000, Dell Storage SCv3000, Dell Storage SCv3020 ...