Connectrix: Slik finner du et serienummer til en DELL EMC Connectrix-svitsj

Résumé: Connectrix: Slik finner du et serienummer til en DELL EMC Connectrix-svitsj

Cet article concerne   Cet article ne concerne pas 

SymptĂŽmes



Slik finner du et serienummer til en DELL EMC Connectrix-svitsj.

Serienummeret til en Dell EMC Connectrix-svitsj er nĂždvendig for Ă„ Ă„pne en serviceforespĂžrsel.

Finner ikke serienummeret til DELL EMC Connectrix.

Cause

IA

RĂ©solution

Connectrix (Brocade)-svitsjer:

I en Connectrix Brocade-svitsj er det fire mÄter Ä fÄ tak i serienummeret pÄ:

  • Logg pĂ„ svitsjen ved hjelp av Telnet eller Secure Shell (SSH), og kjĂžr FOS-kommandoen:
chassisshow

Eksempel:
Brocade#> chassisshow

FAN Unit: 1
Time Awake:             46 days


FAN Unit: 2
Time Awake:             46 days


POWER SUPPLY  Unit: 1
Time Awake:             46 days


POWER SUPPLY  Unit: 2
Time Awake:             46 days


CHASSIS/WWN  Unit: 1
Header Version:         2
Factory Part Num:       40-00XXXX2-04
Factory Serial Num:     AXX0602XX08
Manufacture:            Day: 15  Month: 12  År: 2006
Update:                 Day:  8  Month:  3  Year: 2012
Time Alive:             1502 days
Time Awake:             46 days
ID:                          EMC0000CA               
Part Num:               CONTRX0000500
Serial Num:             BRCAHX00000000
 
Serienummeret for Connectrix Brocade-svitsjen stÄr med fet skrift.
  • Logg inn pĂ„ webverktĂžyene med en nettleser, og skriv inn IP-adressen for svitsjen.
  1. NÄr du har logget pÄ svitsjen, viser hovedsiden et bilde av svitsjen og et omrÄde kalt Switch Event, Information (Svitsjhendelsesinformasjon) under det.
  2. Klikk pÄ fanen som heter Switch Information (Svitsjinformasjon).
  3. Connectrix-serienummeret er oppfĂžrt under fanen Other (Andre) og merket Supplier Serial Number (LeverandĂžrens serienummer).
  • Hvis Connectrix Manager, Connectrix Manager Data Center Edition eller Connectrix Manager Converged Network Edition brukes til Ă„ administrere Connectrix Brocade-svitsjen, er det mulig Ă„ fĂ„ serienummeret fra denne programvaren.
  1. Finn strukturen som svitsjen oppdages i, ved hjelp av strukturvisning.
  2. HÞyreklikk pÄ svitsjen, og velg Egenskaper.
  3. Serienummeret til svitsjen stÄr oppfÞrt i denne fanen.
  • Serienummeret til Connectrix Brocade-svitsjen stĂ„r ogsĂ„ fysisk pĂ„ svitsjen. (Denne informasjonen hentes fra den respektive maskinvareveiledningen for svitsjen, som finnes pĂ„ Dells nettsted for kundestĂžtte.)
Hjem > StĂžtte > Teknisk dokumentasjon og veiledninger > Dokumentasjon for maskinvare/plattformer > Connectrix-kataloger og svitsjer > Generell referanse
 
Serienummeretiketten er plassert slik:
  • AP-7600B i bunnen av kabinettet
  • DS-220B pĂ„ den siden av kabinettet som ikke har porter
  • DS-4100B, DS-4900B og MP-7500B PĂ„ uttrekkstappen for svitsj-ID-en inne i kabinettet pĂ„ siden som har porter, til venstre
  • DS-300B, DS-5000B, DS-5100B og DS-5300B PĂ„ uttrekkstappen for svitsj-ID-en nederst pĂ„ den siden av svitsjen som har porter.
  • ED-48000B Inne i kabinettet ved siden av strĂžmforsyningsbrĂžnnene
  • ED-DCX-B, ED-DCX-4S-SB Nederst til hĂžyre pĂ„ den siden av kabinettet som har porter.
  • DS-6510B- PĂ„ uttrekkstappen for svitsj-ID-en inne i kabinettet pĂ„ siden som har porter, til venstre
  • ED-DCX-8510-8 PĂ„ den siden av kabinettet som har porter, nederst til hĂžyre og rett over kabelhĂ„ndteringskammen
  • ED-DCX-8510-4 PĂ„ den siden av kabinettet som ikke har porter, pĂ„ venstre side av kabinettet rett under den venstre strĂžmforsyningen


Connectrix (Cisco)-svitsjer:

I en Connectrix Cisco-svitsj er det tre mÄter Ä fÄ tak i serienummeret pÄ:

  • Logg pĂ„ svitsjen ved hjelp av Telnet eller Secure Shell (SSH), og kjĂžr CLI-kommandoen:
show license host-id
eller
show inventory.

Eksempel:
CiscoMDS#> show license host-id
License hostid: VDH=FOX1XXXX000

Eksempel:
CiscoMDS3#> show inventory
NAME: "Chassis",  DESCR: "MDS 9513 (13 Slot) Chassis "
PID: DS-C9513            ,  VID: V01 , SN: FOX1XXXX000

NAME: "Slot 1",  DESCR: "16x1GE, Storage Services Node"
PID: DS-X9316-SSNK9      ,  VID: V01 ,  SN: JAEXXXX2YYK

NAME: "Slot 3",  DESCR: "1/2/4/8 Gbps FC Module"
PID: DS-X9248-48K9       ,  VID: V03 ,  SN: JAFXXXXAQPL

NAME: "Slot 7",  DESCR: "Supervisor/Fabric-2a"
PID: DS-X9530-SF2AK9     ,  VID: V01 ,  SN: JAFXXXXCEHP

NAME: "Slot 8",  DESCR: "Supervisor/Fabric-2a"
PID: DS-X9530-SF2AK9     ,  VID: V01 ,  SN: JAFXXXXCEGK

NAME: "Slot 14",  DESCR: "Fabric card module"
PID: DS-13SLT-FAB2       ,  VID: V03 ,  SN: JAFXXXXCHLG

NAME: "Slot 15",  DESCR: "Fabric card module"
PID: DS-13SLT-FAB2       ,  VID: V03 ,  SN: JAFXXXX2CHJM

NAME: "Slot 17",  DESCR: "MDS 9513 (13 Slot) Chassis Power Supply"
PID: DS-CAC-6000W        ,  VID: V01 ,  SN: DCHXXXXX00N

NAME: "Slot 18",  DESCR: "MDS 9513 (13 Slot) Chassis Power Supply"
PID: DS-CAC-6000W        ,  VID: V01 ,  SN: DCHXXXXX00R

NAME: "Slot 19",  DESCR: "MDS 9513 (13 Slot) Chassis Fan Module"
PID: DS-13SLT-FAN-F      ,  VID: V01 ,  SN: DCHXXXX005B

NAME: "Slot 20",  DESCR: "MDS 9513 (13 Slot) Chassis Fan Module"
PID: DS-13SLT-FAN-R      ,  VID: V01 ,  SN: DCHXXXX00RS

NAME: "Slot 21",  DESCR: "MDS 9513 (13 Slot) Chassis Clock Module"
PID: DS-C9513-CL         ,  VID: V01 ,  SN: NWGXXXX01V5

NAME: "Slot 22",  DESCR: "MDS 9513 (13 Slot) Chassis Clock Module"
PID: DS-C9513-CL         ,  VID: V01 ,  SN: NWGXXXX01T9

Serienummeret for Connectrix Cisco stĂ„r i fet skrift i begge eksemplene. 
  • Hvis Fabric Manager eller Data Center Network Manager brukes til administrere Ă„ Connectrix Cisco-svitsjen, er det mulig Ă„ fĂ„ serienummeret fra denne programvaren.
  1. NĂ„r du har Ă„pnet Fabric Manager i Data Center Network Manager, mĂ„ du velge en struktur som serienummeret til svitsjen vi prĂžver Ă„ finne, ligger i.  
  2. Åpne strukturen fra venstre hjĂžrne av skjermen. Det er et omrĂ„de som er merket med Fysiske attributter.
  3. Under Fysiske attributter finnes det en mappe som kalles Svitsjer. I svitsjer velger du alternativet Hardware (Maskinvare).
  4. NĂ„r du velger Hardware, Ă„pnes en visning over strukturkartet som viser all installert maskin vare og serienumrene til maskin varen i den aktuelle strukturen.
  5. Finn de respektive svitsjene ved hjelp av navnene deres, og se etter kabinettets maskinvareinformasjon.
  6. Serienummeret som er oppfĂžrt under maskinvarebeskrivelsen, er serienummeret til svitsjen.
  • Connectrix Cisco-svitsjens serienummer er ogsĂ„ fysisk plassert pĂ„ svitsjen. (Denne informasjonen hentes fra den respektive maskinvareveiledningen for svitsjen som finnes pĂ„ Ciscos nettsted.)
Serienummeretiketten er plassert slik:
  • MDS-9513 – Øverst i midten av kabinettet, pĂ„ portkortsiden av svitsjen.
  • MDS-9509 -– Tidligere versjoner av svitsjen har serienummeret plassert pĂ„ undersiden av portkortsiden av svitsjen, mens senere utgivelser av svitsjen har serienummeret er plassert nederst til venstre pĂ„ portkortsiden av svitsjen.
  • MDS-9506 – Nederst til venstre pĂ„ den siden av svitsjen som vender mot portkortene.
  • NĂ„r det gjelder Connectrix Cisco-svitsjer i avdelingsklasse, finnes serienummeret pĂ„ produktets serviceetikett pĂ„ den siden av svitsjene som har porter. 

Informations supplémentaires

DELL EMC-serviceforespÞrsler kan Äpnes pÄ Internett via Dell-nettstedet for kundestÞtte.
DELL EMC-stÞtte gir ogsÄ tilgang til Ä Äpne en serviceforespÞrsel via live chat-systemet.

Produits concernés

Connectrix

Produits

Connectrix, Connectrix B-Series Hardware, Connectrix MDS-Series Hardware