Dell Technologies: A PM1725a May Go Offline with Various Errors Including "nvme_remove_namespaces"

Résumé: Dell strongly recommends all Dell customers using PM1725a devices with firmware 1.1.1 or earlier to upgrade to firmware 1.1.2 or later as soon as possible.

Cet article concerne Cet article ne concerne pas Cet article n’est associé à aucun produit spécifique. Toutes les versions du produit ne sont pas identifiées dans cet article.

Symptômes

Dell engineers have observed an infrequent issue during system operations, using the Dell PM1725a Express Flash NVMe PCIe SSD, in which the device may go offline and remain inaccessible. The drive may be accessible again after a reboot.

Errors such as "nvme_remove_namespaces," "nvme0n1: detected capacity change from xxxxxxxxx to 0" and various file system errors may be seen in /var, /log, /messages, or other system event logs. Also, continued use of the SSD would require re-creating the file system. This issue has been resolved with a firmware fix.

 

Cause

The issue is caused by a fault in cache management. When the write cache buffer is full, the controller erroneously drops an incoming WRITE operation from the host. This is resolved by servicing incoming WRITE operations from the host after the contents of the cache have been flushed.

 

Résolution

The issue has been resolved as of April 2019 by the Dell Express Flash NVMe PCIe SSD PM1725a firmware release, Version 1.1.2, A03. 
 

WARNING: Dell strongly recommends all Dell customers using PM1725a devices with firmware 1.1.1 or earlier to upgrade to firmware 1.1.2 or later as soon as possible. For instructions on how to update firmware, see Dell knowledge Base article How to Update Firmware Remotely Using the Integrated Dell Remote Access Controller (iDRAC) Web Interface.

 

NOTE: As all versions of PM1725a firmware prior to 1.1.2 are susceptible to this issue, firmware other than 1.1.2 has been removed from the Dell support website and is no longer available for download.

 

Produits concernés

Storage Spaces Direct R640 Ready Node, Storage Spaces Direct R740xd Ready Node, PowerEdge R640, PowerEdge R740, PowerEdge R740XD, PowerEdge R740XD2, PowerEdge R830, PowerEdge R840
Propriétés de l’article
Numéro d’article: 000177934
Type d’article: Solution
Dernière modification: 13 mars 2024
Version:  5
Trouvez des réponses à vos questions auprès d’autres utilisateurs Dell
Services de support
Vérifiez si votre appareil est couvert par les services de support.