This tutorial explains how to update the firmware of your hard disks on your PowerVault disk array.
Note: This article is part of the
Dell PowerVault knowledge library.
The following precautions should be taken before updating drives:
- The procedure requires a production shutdown to be implemented.
- The array has to be in an "Optimal" state.
Prerequisites:
No IO should be written on the disks during the update. The LUNs will have to be removed from the servers, or the servers accessing to it will have to be turned off.
As a precautionary measure, it is recommended that you have a complete backup of the present data on the array.
Download the latest update package "
Dell PowerVault MD Series Storage HDD/SSD Firmware" . Package is in the
Enterprise HDD/SSD folder.
1. Unzip package to management station (server running MDSM Software)
2. From the array management window select
Advanced >
Maintenance >
Download >
Physical Disk Firmware...
3. Wizard will start with instructions on how to update drive firmware.
For example:
\MD32x0_MD32x0i_MD36x0i_HDD_FW_A2_R304271\Seagate_ST3500414SS_KS69.df
\MD32x0_MD32x0i_MD36x0i_HDD_FW_A2_R304271\Hitachi
Hitachi_HUS156045VLS600_E516.df
Figure 1: MDSM update package selection screen
- Once the packages selected, click on "Next" and validate.
- A message will appear informing you on the success of the update.
Note: The process of update can last up for 20 minutes.