Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Create and access a list of your products

PowerStore:在執行 PowerStoreOS 3.0 或 3.2 版時,具有 SAS 擴充機櫃的叢集可能會發生節點意外重新開機

Summary: 具有一個或多個 SAS 擴充機櫃的叢集在執行 PowerStoreOS 3.0 或 3.2.0 版時,可能會遇到節點意外重新開機。

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

如果符合這些條件,PowerStore 節點可能會意外重新開機:
  • 叢集位於 PowerStoreOS 版本 3.0.x 或 3.2.0.x 上
  • 叢集中任何裝置附加一或多個 SAS 擴充機櫃。

Cause

SAS 控制器上的鎖定問題可能會使 SAS 驅動程式逾時。
這又會導致節點意外重新開機。

Resolution

 PowerStoreOS 3.2.1.0 版包含有助於緩解此問題的改善專案。此問題的修正方法是在 PowerStoreOS 3.5 中。

Affected Products

PowerStore
Article Properties
Article Number: 000203131
Article Type: Solution
Last Modified: 20 May 2024
Version:  23
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.