Connectrix: Brocade B series: Switch stuck in continuous random reboot "reset reason was 0x00000001: Power Up"

Summary: A Brocade B series switch may become stuck in a continuous reboot loop. The switch cannot be accessed over SSH or through the console.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Logging into the switch through the serial console reveals the following error:
BootROM version: 3.0.4 
Copyright (C) 2016 Brocade Communication.

CPU0:  T1022E, Version: 1.1, (0x85290211)
Core:  e5500, Version: 2.1, (0x80241021)
Single Source Clock Configuration
Clock Configuration:
       CPU0:1200 MHz, CPU1:1200 MHz, 
       CCB:500  MHz,
       DDR:600  MHz (1200 MT/s data rate) (Asynchronous), IFC:62.500 MHz
       FMAN1: 500 MHz
       QMAN:  250 MHz
       PME:   250 MHz
L1:    D-cache 32 KiB enabled
       I-cache 32 KiB enabled
Model ID: 170
Board: CHEWBACCA24, 36-bit Addressing
reset reason was 0x00000001: Power Up
I2C:   ready
SPI:   ready
DRAM:  Initializing....
Detected UDIMM WL3SE902G16NSF-BRD
ctrl_num = 0: RDIMM in RST Mode, use initialization
..........
Tune was failed. Resetting system..

Cause

The switch cannot find a file system or fabric operating system (FOS). The switch resets soon after powering up due to a failed memory test.

Resolution

The switch must be replaced.

Affected Products

Connectrix B-Series Hardware

Products

Connectrix B-Series