Fabric OS 9.1.1c
Utdata visar fel när du kör ett inlinekommando från en UNIX- eller Linux-server. Kommandot slutar svara när en annan logisk switch-FID på samma chassi avsöker. Exempel:
[hosttest@VM1234 ~]$
[hosttest@VM1234 ~]$ ssh aa.bb.cc.dd fosexec --fid 44 -cmd 'firmwareshow'
hosttest@aa.bb.cc.dd's password:
/bin/stty: 'standard input': Inappropriate ioctl for device
/bin/stty: 'standard input': Inappropriate ioctl for device
/etc/ssh_inline_profile: line 25: FUNCNEST: readonly variable
Appl Primary/Secondary Versions
------------------------------------------
FOS v9.1.1c
v9.1.1c
---------------------------------------------------
"firmwareshow" on FID 44:
[hosttest@VM3198 ~]$
[hosttest@VM3198 ~]$
[hosttest@VM3198 ~]$ ssh aa.bb.cc.dd fosexec --fid 44 -cmd 'firmwareshow'
hosttest@10.60.23.25's password:
/bin/stty: 'standard input': Inappropriate ioctl for device
/bin/stty: 'standard input': Inappropriate ioctl for device
Appl Primary/Secondary Versions
------------------------------------------
FOS v9.2.0a
v9.2.0a
---------------------------------------------------
"firmwareshow" on FID 44:
[hosttest@VM3198 ~]$
Uppgradera till Fabric OS 9.2.0b eller senare.
Kör kommandona direkt på switchen.