PowerPath: Restablecimiento de la conexión por par cuando Tenable Vulnerability escanea el puerto 9083

Summary: La administración remota de PowerPath para Windows 7.2.X con seguridad de capa de transporte mutua (mTLS) alcanza el límite máximo de conexión de conector y el restablecimiento de la conexión por par cuando Tenable Vulnerability escanea el puerto 9083. ...

This article may have been automatically translated. If you have any feedback regarding its quality, please let us know using the form at the bottom of this page.

Article Content


Symptoms

Cuando el software de escaneo Tenable escanea el puerto 9083, el proceso de administración remota de PowerPath con mTLS habilitado falla y, finalmente, alcanza el máximo de conexiones de socket y se registra el restablecimiento de la conexión mediante un mensaje de par.

 

En la GUI de PPMA, el estado desconectado no se observa hasta el siguiente ciclo de sondeo. Cuando se ejecuta el ciclo de sondeo, el servidor finalmente se muestra como desconectado en la GUI (ROJO).

 

## Registro de eventos de la aplicación Administración remota de Windows

07/23/2023 07:05:23 PM  Warning       HOSTNAME 3       EmcPowerPathManagementComponent  EMC PowerPath Warning:  Management Component: Warning: Max socket connection limit reached, incoming connection dropped. Remote host: ip=10.x.x.x, hostname=PPMAHOST.DOMAIN.COM.
07/23/2023 07:05:23 PM  Information   HOSTNAME 2       EmcPowerPathManagementComponent  EMC PowerPath Information:  Management Component: Info: SSPI decryption failed. InitSSLServerSchannel(): Failed to query the client.
07/23/2023 07:05:19 PM  Warning       HOSTNAME 3       EmcPowerPathManagementComponent  EMC PowerPath Warning:  Management Component: Warning: Max socket connection limit reached, incoming connection dropped. Remote host: ip=10.x.x.x, hostname=PPMAHOST.DOMAIN.COM.
07/23/2023 07:05:19 PM  Error         HOSTNAME 4       EmcPowerPathManagementComponent  EMC PowerPath Error:  Management Component: Error: Socket library: send - Connection reset by peer. (err=10054).
07/23/2023 07:05:18 PM  Warning       HOSTNAME 3       EmcPowerPathManagementComponent  EMC PowerPath Warning:  Management Component: Warning: Max socket connection limit reached, incoming connection dropped. Remote host: ip=10.x.x.x, hostname=PPMAHOST.DOMAIN.COM.
07/23/2023 07:05:18 PM  Error         HOSTNAME 4       EmcPowerPathManagementComponent  EMC PowerPath Error:  Management Component: Error: Socket library: send - Connection reset by peer. (err=10054)

 

## Registro de PPMA DataCollector

ERROR 19:16:08.320 [AnonymousIoService-6] c.e.p.d.hosts.impl.HostAgentListener - Internal error occurred in the connection to HOSTNAME.DOMAIN.COM:9083
WARN  19:16:08.321 [AnonymousIoService-6] c.e.p.d.h.impl.HostAgentConnector - java.lang.Exception: Invalid Header Tag       ??U? (Hexdump: 15 03 03 00 1A 00 00 00 00 00 00 00 01 99 FB 16 55 98 19 50 B2 E1 87 35 F2 0D 26 E6 F4 A1 6D)
org.apache.mina.filter.codec.ProtocolDecoderException: java.lang.Exception: Invalid Header Tag       ??U? (Hexdump: 15 03 03 00 1A 00 00 00 00 00 00 00 01 99 FB 16 55 98 19 50 B2 E1 87 35 F2 0D 26 E6 F4 A1 6D)
    at org.apache.mina.filter.codec.ProtocolCodecFilter.messageReceived(ProtocolCodecFilter.java:165)
    at org.apache.mina.common.support.AbstractIoFilterChain.callNextMessageReceived(AbstractIoFilterChain.java:299)
    at org.apache.mina.common.support.AbstractIoFilterChain.access$1100(AbstractIoFilterChain.java:53)
    at org.apache.mina.common.support.AbstractIoFilterChain$EntryImpl$1.messageReceived(AbstractIoFilterChain.java:648)
    at org.apache.mina.filter.support.SSLHandler.flushScheduledEvents(SSLHandler.java:275)
    at org.apache.mina.filter.SSLFilter.messageReceived(SSLFilter.java:427)
    at org.apache.mina.common.support.AbstractIoFilterChain.callNextMessageReceived(AbstractIoFilterChain.java:299)
    at org.apache.mina.common.support.AbstractIoFilterChain.access$1100(AbstractIoFilterChain.java:53)
    at org.apache.mina.common.support.AbstractIoFilterChain$EntryImpl$1.messageReceived(AbstractIoFilterChain.java:648)
    at org.apache.mina.filter.executor.ExecutorFilter.processEvent(ExecutorFilter.java:220)
    at org.apache.mina.filter.executor.ExecutorFilter$ProcessEventsRunnable.run(ExecutorFilter.java:264)
    at java.util.concurrent.ThreadPoolExecutor.runWorker(ThreadPoolExecutor.java:1149)
    at java.util.concurrent.ThreadPoolExecutor$Worker.run(ThreadPoolExecutor.java:624)
    at org.apache.mina.util.NamePreservingRunnable.run(NamePreservingRunnable.java:51)
    at java.lang.Thread.run(Thread.java:750)
Caused by: java.lang.Exception: Invalid Header Tag       ??U?
    at com.emc.powerpath.datacollector.remote.nio.mina.client.codec.AgentResponseDecoder.getExpectedBytes(AgentResponseDecoder.java:64)
    at com.emc.powerpath.datacollector.remote.nio.mina.client.codec.AgentResponseDecoder.doDecode(AgentResponseDecoder.java:117)
    at org.apache.mina.filter.codec.CumulativeProtocolDecoder.decode(CumulativeProtocolDecoder.java:133)
    at org.apache.mina.filter.codec.ProtocolCodecFilter.messageReceived(ProtocolCodecFilter.java:158)
    ... 14 common frames omitted
WARN  19:16:08.325 [AnonymousIoService-14] c.e.p.d.h.impl.HostAgentConnector - Connection reset by peer
java.io.IOException: Connection reset by peer
    at sun.nio.ch.FileDispatcherImpl.read0(Native Method)
    at sun.nio.ch.SocketDispatcher.read(SocketDispatcher.java:39)
    at sun.nio.ch.IOUtil.readIntoNativeBuffer(IOUtil.java:223)
    at sun.nio.ch.IOUtil.read(IOUtil.java:197)
    at sun.nio.ch.SocketChannelImpl.read(SocketChannelImpl.java:378)
    at org.apache.mina.transport.socket.nio.SocketIoProcessor.read(SocketIoProcessor.java:218)
    at org.apache.mina.transport.socket.nio.SocketIoProcessor.process(SocketIoProcessor.java:198)
    at org.apache.mina.transport.socket.nio.SocketIoProcessor.access$400(SocketIoProcessor.java:45)
    at org.apache.mina.transport.socket.nio.SocketIoProcessor$Worker.run(SocketIoProcessor.java:485)
    at org.apache.mina.util.NamePreservingRunnable.run(NamePreservingRunnable.java:51)
    at java.lang.Thread.run(Thread.java:750)
WARN  19:16:08.325 [AnonymousIoService-14] c.e.p.d.h.impl.HostAgentConnector - Broken pipe
java.io.IOException: Broken pipe
    at sun.nio.ch.FileDispatcherImpl.write0(Native Method)
    at sun.nio.ch.SocketDispatcher.write(SocketDispatcher.java:47)
    at sun.nio.ch.IOUtil.writeFromNativeBuffer(IOUtil.java:93)
    at sun.nio.ch.IOUtil.write(IOUtil.java:65)
    at sun.nio.ch.SocketChannelImpl.write(SocketChannelImpl.java:469)
    at org.apache.mina.transport.socket.nio.SocketIoProcessor.doFlush(SocketIoProcessor.java:414)
    at org.apache.mina.transport.socket.nio.SocketIoProcessor.doFlush(SocketIoProcessor.java:332)
    at org.apache.mina.transport.socket.nio.SocketIoProcessor.access$500(SocketIoProcessor.java:45)
    at org.apache.mina.transport.socket.nio.SocketIoProcessor$Worker.run(SocketIoProcessor.java:488)
    at org.apache.mina.util.NamePreservingRunnable.run(NamePreservingRunnable.java:51)
    at java.lang.Thread.run(Thread.java:750)
ERROR 19:16:08.325 [AnonymousIoService-14] c.e.p.d.hosts.impl.HostAgentListener - Connection to HOSTNAME.DOMAIN.COM:9083 has been lost

 

Cause

Este problema se debe a que la administración remota de PowerPath para Windows 7.2.X con mTLS habilitado no maneja correctamente las conexiones de Winsock desde un servidor que no es PPMA.

 

Resolution

La corrección estará en la versión futura de PowerPath para Windows, pero no hay una ETA en este momento.

 

La solución alternativa es reiniciar el servicio "componente de EMC PowerPath Remote Management" desde los servicios de Windows.

 