Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Enjoy members-only rewards and discounts
  • Create and access a list of your products

ECS: xDoctor: RAP163: Kritická událost systémové paměti

Summary: Došlo ke kritické události systémové paměti, kterou je třeba zkontrolovat a vyměnit ve formátu DIMM.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Aplikace xDoctor hlásí kritickou událost systémové paměti, kterou je třeba zkontrolovat.
------------------------------------
ERROR - Critical System Memory Event
------------------------------------
Node      = Nodes
Extra     = {'Nodes': {'169.254.1.1': ['Memory #0x02 - Uncorrectable ECC (UnCorrectable ECC |  DIMMB1) (06/10/2023 08:45:16)', 'Memory #0x03 - Uncorrectable ECC (UnCorrectable ECC |  DIMMB1) (06/10/2023 08:45:16)', 'Memory Mmry ECC Sensor - Correctable ECC (11/26/2015 12:38:51)']}}
RAP       = RAP163
Solution  = KB 215723
Timestamp = 2023-07-10_170539
PSNT      = CKMXXXXXXXXXXX @ 4.8-92.0

Cause

POZNÁMKA: Pokud některý z modulů DIMM chybí nebo se v protokolech systémových událostí (SEL) zobrazuje událost Uncorrectable, je nutné moduly DIMM vyměnit.
  1. Zkontrolujte protokoly SEL a ověřte, zda jsou na uzlu neopravitelné chyby.

Příkaz: (Vzdálený příkaz)

# sudo ipmitool -H <iDrac IP> -U root -P passwd -I lanplus sel elist

Příkaz: (Místní uzel)

# sudo ipmitool sel elist

Příklad:

admin@node1:~> sudo ipmitool -H 192.XXX.2XX.107 -U root -P passwd -I lanplus sel elist
   1 | 12/04/2021 | 07:29:19 | Event Logging Disabled SEL | Log area reset/cleared | Asserted
   2 | 12/29/2021 | 23:00:29 | Memory Mem ECC Warning | Transition to Critical from less severe | Asserted
   3 | 01/26/2022 | 11:44:08 | Memory Mem ECC Warning | Transition to Critical from less severe | Asserted
   4 | 08/03/2022 | 18:31:45 | Power Supply PS Redundancy | Redundancy Lost | Asserted
   5 | 08/03/2022 | 18:31:48 | Power Supply Status | Power Supply AC lost | Asserted
   6 | 08/03/2022 | 18:43:14 | Power Supply Status | Power Supply AC lost | Deasserted
   7 | 08/03/2022 | 18:43:22 | Power Supply PS Redundancy | Fully Redundant | Asserted
   8 | 08/03/2022 | 18:51:27 | Power Supply PS Redundancy | Redundancy Lost | Asserted
   9 | 08/03/2022 | 18:51:27 | Power Supply Status | Power Supply AC lost | Asserted
   a | 08/03/2022 | 19:02:03 | Power Supply Status | Power Supply AC lost | Deasserted
   b | 08/03/2022 | 19:02:14 | Power Supply PS Redundancy | Fully Redundant | Asserted
   c | 01/19/2023 | 05:38:27 | Memory Mem ECC Warning | Transition to Critical from less severe | Asserted
   d | 02/06/2023 | 02:10:25 | Memory Mem ECC Warning | Transition to Critical from less severe | Asserted
   e | 03/02/2023 | 17:12:15 | Memory Mem ECC Warning | Transition to Critical from less severe | Asserted
   f | 05/09/2023 | 15:56:41 | Memory #0x02 | Uncorrectable ECC (UnCorrectable ECC |  DIMMA1) | Asserted
  10 | 05/09/2023 | 17:16:16 | Memory Mem ECC Warning | Transition to Critical from less severe | Asserted
  11 | 05/09/2023 | 20:57:41 | Memory #0x02 | Uncorrectable ECC (UnCorrectable ECC |  DIMMA1) | Asserted
  12 | 05/09/2023 | 20:59:25 | Unknown #0x2e |  | Asserted
  13 | 05/09/2023 | 20:59:25 | Memory #0x02 | Uncorrectable ECC (UnCorrectable ECC |  DIMMB1) | Asserted
  14 | 05/11/2023 | 05:43:34 | Memory Mem ECC Warning | Transition to Critical from less severe | Asserted
  15 | 06/10/2023 | 08:43:26 | Memory #0x02 | Uncorrectable ECC (UnCorrectable ECC |  DIMMA1) | Asserted
  16 | 06/10/2023 | 08:45:16 | Unknown #0x2e |  | Asserted
  17 | 06/10/2023 | 08:45:16 | Memory #0x02 | Uncorrectable ECC (UnCorrectable ECC |  DIMMA1) | Asserted
  18 | 06/10/2023 | 08:45:16 | Memory #0x02 | Uncorrectable ECC (UnCorrectable ECC |  DIMMB1) | Asserted
  1. Zkontrolujte, zda kvůli události nechybí nějaké moduly DIMM.

Příkaz:

# sudo dmidecode -t memory | grep "Locator\|Size" | grep -v "Cache\|Volatile\|Cache\|Logical\|Bank"

Příklad:

admin@node1:~> sudo dmidecode -t memory | grep "Locator\|Size" | grep -v "Cache\|Volatile\|Cache\|Logical\|Bank"
        Size: No Module Installed <-- DIMM is missing
        Locator: A1
        Size: 16384 MB
        Locator: A2
        Size: No Module Installed
        Locator: A3
        Size: No Module Installed
        Locator: A4
        Size: No Module Installed
        Locator: A5
        Size: No Module Installed
        Locator: A6
        Size: No Module Installed
        Locator: A7
        Size: No Module Installed
        Locator: A8
        Size: 16384 MB
        Locator: B1
        Size: 16384 MB
        Locator: B2
        Size: No Module Installed
        Locator: B3
        Size: No Module Installed
        Locator: B4

Resolution

Shromážděte výstupy z výše uvedených příkazů, otevřete servisní požadavek s odkazem na článek KB 215723 a zkontrolujte serverový modul DIMM pro výměnu. 


Pokud došlo k úspěšné výměně modulu DIMM, aplikace xDoctor verze 4.8.92.0 nebo vyšší vyžaduje vymazání protokolu SEL na dotčeném uzlu. Zastaví další výstrahy u této položky protokolu.


Příklad – vymazání protokolu systémových událostí (SEL):

Dotazem řadiče iDRAC získejte protokol systémových událostí a ověřte, zda je chyba obsažena ve výstupu. 

Nezapomeňte, že před vymazáním protokolu SEL zkontrolujte, zda nejsou k dispozici další chyby, které je třeba vyřešit. Protokol také uložte do /var/log/hardware jak je popsáno v části KB 49569.

V tomto příkladu adresa 192.168.219.101 odpovídá IP adrese řadiče iDRAC uzlu 1:

admin@provo~> ipmitool -I lanplus -H 192.168.219.101 -U root -P passwd sel list
   1 | 01/06/2022 | 04:34:58 | Event Logging Disabled #0x72 | Log area reset/cleared | Asserted
   2 | 02/03/2022 | 17:15:21 | Physical Security #0x73 | General Chassis intrusion () | Asserted
   3 | 02/03/2022 | 17:15:28 | Physical Security #0x73 | General Chassis intrusion () | Deasserted
   4 | 08/18/2023 | 01:44:01 | Memory #0x02 | Uncorrectable ECC (UnCorrectable ECC |  DIMMA1) | Asserted


  Vymažte protokol SEL: 

admin@provo:~> ipmitool -I lanplus -H 192.168.219.101 -U root -P passwd sel clear
Clearing SEL.  Please allow a few seconds to erase.


Ověřte, že seznam nebyl vymazán:

admin@provo~> ipmitool -I lanplus -H 192.168.219.101 -U root -P passwd sel list
   1 | 08/30/2023 | 12:56:55 | Event Logging Disabled #0x72 | Log area reset/cleared | Asserted
 

Affected Products

ECS Appliance Gen 3

Products

ECS Appliance
Article Properties
Article Number: 000215723
Article Type: Solution
Last Modified: 30 May 2024
Version:  7
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.