Known issues, environmental and system requirements, and installation or update considerations associated with these patch releases are the same as the parent release. For more information, see the
Dell EMC PowerProtect DDOS, DD Virtual Edition (DDVE), DD Management Center (DDMC), DD BoostFS, and DD Boost for OpenStorage 7.10.0.0 Release Notes.
Release Revision History
Release |
Description |
7.10.1.30 |
- Initial release of 7.10.1.30 (June 2024)
- Correction: ESE Connectivity Telemetry and SupportAssist are not supported in the 7.9.x or 7.10.x releases.
|
7.10.1.20 |
- Initial release of 7.10.1.20 (February 2024)
|
7.10.1.15 |
- Initial release of 7.10.1.15 (December 2023)
- See DSA-2023-412 for security updates for this release.
- SE Mode has been deprecated.
- See this information before planning a DDOS update:
|
7.10.1.10 |
- Initial release of 7.10.1.10 (October 2023)
|
7.10.1.1 |
- Initial release of 7.10.1.1 (June 2023)
|
7.10.1.0 |
- Initial release of 7.10.1.0 (April 2023)
|
Associated Build Versions
- DDOS Build: 7.10.1.30-1105324
- DDVE Build: 7.10.1.30-1105324
- DDMC Build: 7.10.1.30-1105324
DDOS File System
Fixed Issue |
Description |
DDOSCFD-19783 |
Fixed the issue where users were unable to log in to Enterprise Manager (EM) after configuring LDAP. |
DDOSCFD-19311 |
This fix addresses the HSTS missing from HTTPS server. |
DDOSCFD-18403 |
Fixed the issue for the customer-imported certificates in DDSM Smart Scale, where the externally signed certificates are stored in the HTTPS certificate root folder. |
DDOSCFD-18267 |
Fixed the issue of PANIC due to race condition in AIR REPL workflow causing the PANIC in customer environment. |
DDOS-229120 |
Fixed the issue of service denial when the export file overwrites the .system file. |
DDOS-207653 |
Fixed the issue of Autosupport command that does not display an error for the invalid command. |
DDOS-181245 |
Fixed the issue of Network Time Protocol (NTP) backporting done and vulnerabilities. |
DDOS General
Fixed Issue |
Description |
DDOSCFD-19046 |
Fixed the issue of static routes missing after upgrading to DDOS 7.10.1.15. |
DDOSCFD-18428 |
Fixed the issue where DD UI does not display the VTL tapes from Cloud Tier. |
DDOS Platform
Fixed Issue |
Description |
DDOSCFD-19507 |
Fixed the issue that restarts the system from panic due to online OEC platform. |
DDOSCFD-19467 |
Fixed the issue of active/cache/cloud tier unavailable alert appearing after headswap failure. |
DDOSCFD-18760 |
This fixes the issue of file system panic observed when you run the dd_sptool --resync command. |
DDOSCFD-17954 |
Fixed the issue of display error: "This command has unexpectedly aborted." |
DDOS-234450 |
Fixed the issue of the Async procedure taking longer and displays a message: "PANIC: ddr/nfs/nfs_rpc.c: nfs_rpc_debug_cb: 427". |
DDOS-173347 |
Fixed the issue of storage expansion failure. |
DDOS Replication
Fixed Issue |
Description |
DDOSCFD-18348 |
Fixed the issue to handle fanout error when running the replication. |
DDOS Security
Fixed Issue |
Description |
DDOS-216358 |
Fixed the issue to remove unvalidated redirects and forwards when DDSM accepts untrusted inputs. |
DDOS-177759 |
Fixed the issue on Smart Scale DDOS 7.10 of running DDMC application with root privileges by default. |
Associated Build Versions
- DDOS Build: 7.10.1.20-1090468
- DDVE Build: 7.10.1.20-1090468
- DDMC Build: 7.10.1.20-1090468
- OST Plugin Build: 7.10.1.20-1083082
DDOS Security
Fixed Issue |
Description |
DDOS-179017 |
Remediation of LDAP injection security vulnerability. |
DDOS-197917 |
Remediation for CVE-2023-0464,CVE-2023-0466,CVE-2023-0465,CVE-2023-2650. |
DDOS-205345 |
Remediation for NVD CVE-2022-1271 (BDSA-2022-0958). |
DDOS-208574 |
Remediation of registry value vulnerability. |
DDOS-213045 |
Remediation of "se view" command vulnerability. |
DDOS-213050 |
Remediation of SmartScale password vulnerability. |
DDOS-224614 |
A system passphrase force-update regression was required after the previous access mode was deprecated. |
DDOSCFD-13936 |
Remove MD5 and 96-bit MAC algorithms in SSH. |
DDOSCFD-16292 |
Remediation of AD/LDAP group name issues. |
DDOSCFD-16989 |
Disable SNMP agent in IDRAC and keep SNMPV1 for inter-communication of IDRAC trap to DDOS. |
DDOSCFD-17069 |
IDRAC security banner added to remind the user not to change configuration in IDRAC. |
DDOS DD CIFS/NFS
Fixed Issue |
Description |
DDOS-222533 |
SS container base was regenerated for backporting. |
DDOSCFD-16857 |
The API request or response was working, while the response contained incorrect information for CIFS status. |
DDOS DDMC
Fixed Issue |
Description |
DDOSCFD-16896 |
Fixed an issue where when attempting to create a PCM (Physical Capacity Measurement) schedule, no MTrees are listed in the target selection. |
DDOS File System
Fixed Issue |
Description |
DDOS-153559 |
The file system panicked after an upgrade. |
DDOS-166378 |
There were improvements to fm_dump_async() to reduce the likelihood of the inode cache getting hot. |
DDOS-172568 |
The "enclosure show topology" previously panicked. |
DDOS-173495 |
SMS disk to copy boot files after adding to PEM in the storage pool. |
DDOS-177710 |
The file system was disabled and shut down. |
DDOS-199911 |
This fix selectively uses filesys for deleting files in superblocks. |
DDOS-200575 |
After pulling a disk from ithaca-14 Volume vol1 was unavailable! and disks were in 0 state. |
DDOS-208699 |
After the HU disk panicked, new disks were swapped. |
DDOS-216870 |
The level log filling messages were debugged. |
DDOS-217884 |
The DIV was changed to support 1.92 TB boot disks. |
DDOS-219095 |
The 10 GC and 3 Scavenge DUTI failing due to "cm_oec"tool. |
DDOS-224477 |
The DD Boost client version was updated for DD system upgrade compatibility. |
DDOSCFD-13100 DDOSCFD-16548 |
The garbage collection issue was addressed. |
DDOSCFD-14559 |
The directory manager panicked after a system upgrade due to a CC partition issue. |
DDOSCFD-15317 |
The system restarted and displayed this message: "PANIC: ddr/dm/dmbt_iface.c: dmbt_intr_page_split: 14546: iipage->hdr.free_offset != iipage->hdr.entry_count. Namespace issue?" |
DDOSCFD-16184 |
The system was irresponsive after an upgrade. |
DDOSCFD-16240 |
After an upgrade, the system received the error message: "PANIC: ddr/dm/dm_check.c: _dm_fsck_intern: 1812: Fatal Error" |
DDOSCFD-17809 |
After the DDOS upgrade completed, the user noticed that the file system was not stable and kept restarting and failing. |
DDOS General
Fixed Issue |
Description |
DDOS-218452 |
This fix addresses the Lot 9 DAE PSU fan fault. |
DDOS-222479 |
Updated the docker base image for CPS, MPS, db, db_mgr, and lockbox services. |
DDOS DD Networking
Fixed Issue |
Description |
DDOS-171022 |
The driver and firmware were updated for Intel and Broadcom devices. |
DDOS-173403 |
An installation panicked due to rsync rpm file. |
DDOS-222730 |
The user experienced an issue as "veth1667" for the port which was dedicated to the replication. The port remained down after fail back. |
DDOS-225218 |
The member interface in a failover bond did not display the correct link state after a link failover in the bond. |
DDOSCFD-17770 |
An HA failure was launched due lost of connectivity at all levels. |
DDOSCFD-17780 |
User experienced the alert containing- "NOTICE: MSG-DDSH-00017: (tty=<>, session=7741, cradmin: command "net config veth0 up" exited with code: 61" getting generated. |
DDOSCFD-17476 |
After an upgrade, the user had an issue with the "veth1667" port which is dedicated to the replication and remained down after fail back. |
DDOSCFD-17481 |
HA failure launched due lost of connectivity at all levels. |
DDOSCFD-17917 |
The DLM alias come up after a system upgrade. |
DDOS DD Platform
Fixed Issue |
Description |
DDOS-200884 |
The iDRAC lifecycle log message generated by iDRAC 6.x had a prefix. |
DDOS-223476 |
The historical database upgrade panicked after the system was upgraded. |
DDOSCFD-12822 |
The HA pair did not dial home: "standby node can only manage pnode events" |
DDOSCFD-15845 |
The platmon command did not post a DIMM faulty alert when a MEM0001 event occurred. The corresponding alert was not sent if it happened before the latest reset. |
DDOSCFD-16146 |
The grub update caused the system to panic in post installation. |
DDOSCFD-16158 |
The power supply generated alerts. |
DDOSCFD-16484 |
The HA degraded alert due to SMS panic during sms_system_package_show_installed command with the message: "realloc(): invalid next size" |
DDOSCFD-17165 |
An HA system was unable to retrieve firmware information. |
DDOS Protocol
Fixed Issue |
Description |
DDOS-211593 |
This release fixes the length of the serial number in the VTL response of the SCSI INQUIRY command for IBM TS3500 changer. Previously, the serial number was shown truncated to 10 characters instead of showing all 12 characters. |
DDOSCFD-18206 |
The system corrects the DD hostname truncation, but resulted in a memory allocation error. |
DDOS Replication
Fixed Issue |
Description |
DDOS-162260 |
A DD file system core was observed after an HA failover. |
DDOS-166885 |
An HA system was unable to bring the file system online after a lab power outage. |
Associated Build Versions
- DDOS Build: 7.10.1.15-1078832
- DDVE Build: 7.10.1.15-1078832
- DDMC Build: 7.10.1.15-1078832
Fixed Issue |
Description |
DDOSCFD-16516 |
Remediation of escalation of privilege vulnerability. |
DDOSCFD-17123 |
Remediation of OS command injection vulnerability. |
DDOSCFD-17599 |
Remediation of OS command injection vulnerability. |
DDOSCFD-17600 |
Remediation of DOM-based XSS vulnerability. |
DDOSCFD-17601 |
Remediation of SQL injection vulnerability. |
DDOSCFD-17174 |
Remediation of improper path traversal and OS command injection vulnerabilities. |
Associated Build Versions
- DDOS Build: 7.10.1.10-1068159
- DDVE Build: 7.10.1.10-1068159
- DDMC Build: 7.10.1.10-1068159
- DD BoostFS Build: 7.10.1.10-1058783
- OST Plugin Build: 7.10.1.10-1068159
DDOS Security
Issue |
Description |
DDOS-150916 |
Security fix to address vulnerabilities. |
DDOS-155586 |
Security fix to address CVE-2022-0847. |
DDOS-169498 |
Security fix to address vulnerabilities. |
DDOS-194227 |
Security fix to address vulnerabilities. |
DDOSCFD-14872 |
Security fix to address vulnerabilities. |
DDOSCFD-14916 |
Security fix to address vulnerabilities. |
DDOSCFD-14945 |
Security fix to address vulnerabilities. |
DDOSCFD-15122 |
Security fix to address CVE-2022-31129. |
DDOSCFD-15123 |
Security fix to address CVE-2021-23337. |
DDOSCFD-15869 |
Security fix to address vulnerabilities. |
DDOSCFD-15989 |
Security fix to address vulnerabilities. |
DDOSCFD-16118 |
Security fix to address vulnerabilities. |
DDOSCFD-16119 |
Security fix to address vulnerabilities. |
DDOS DD CIFS/NFS
Issue |
Description |
DDOS-180509 |
Inability to expire via CIFS to Compliance mode, caused the system to panic. |
DDOSCFD-15631 |
This CIFS issue caused the system to panic. |
DDOS Cloud
Issue |
Description |
DDOS-189902 |
The filesys incorrectly reported a system panic. |
DDOSCFD-15692 |
Incorrect panic was caused when HA mode was called by DDMC on cloud system. |
DDOSCFD-16463 |
The issue which caused the system to panic and the following message was fixed: "PANIC: ddr/repl/lrepl_client.c: filecopy_close_local: 12261: filecopy ctx 541: mismatched chksums orig -671012825 repl -1475858379" |
DDOS DD Boost
Issue |
Description |
DDOSCFD-16634 |
DD Boost OST issue caused the DD hostname to be truncated, causing system to panic. |
DDOS File System
Issue |
Description |
DDOSCFD-14359 |
A system upgrade caused an LLC timeout which resulted in recovered inflight stripes. |
DDOSCFD-14503 |
Although the file system showed an active alert, the issue appeared as resolved on Cloud IQ. |
DDOSCFD-14558 |
The file system panicked with this message "PANIC: ddr/dm/dm_mrepl.c: _dm_mrepl_filter_delta_buffer: 5096: No entry matching cookie". |
DDOSCFD-14858 |
Firmware upgrade caused file system to become unavailable. |
DDOSCFD-15256 |
After an upgrade was completed, the disks showed as "known status" and the file system showed as "not existing". |
DDOSCFD-15336 |
The file system issue which caused this message was fixed. "PANIC: ddr/dm/dmbt_iface.c: dmbt_scm_cache_sync_lock_free: 5602: Fatal Error" |
DDOSCFD-15649 |
The issue that caused the file system to panic and shutdown after an upgrade was fixed. |
DDOSCFD-15650 |
This disk panic caused an HA node to become degraded. |
DDOSCFD-15867 |
A system panic occurred when customer had huge capacity values. |
DDOSCFD-15978 |
The file system restarted multiple times and caused the following error, aaaaaaaa'PANIC: ddr/dm/dmbt_iface.c: dmbt_get_entry_inode: 19746: !(ret == DD_ERR_NONEa' |
DDOSCFD-16012 |
This file system issue caused the system to restart. |
DDOSCFD-16121 |
A firmware update caused the file system to become unavailable. |
DDOS DD Platform
Issue |
Description |
DDOSCFD-14690 |
The fix addresses this issue that occurred after an upgrade. "WARNING Firmware EVT-FIRMWARE-00002: One or more of the system's hardware components is running on an outdated firmware version." |
DDOSCFD-15119 |
The fix handles the exception when the PTAgent is not working during upgrade. |
DDOS Replication
Issue |
Description |
DDOSCFD-15598 |
This DD Boost issue caused a system panic during replication: "PANIC: ddr/repl/srepl.c: srepl_do_process_pattern_match: 2090: !(*remote_array_offset < max_candidates)". |
DDOSCFD-15879 |
A replication issue caused this system message, "PANIC: ddr/repl/lrepl_client.c: mrepl_send_file: 16638: repl ctx 6:1: mrepl_send_file: I/O error". |
Associated Build Versions
- DDOS Build: 7.10.1.1-1049892
- DDVE Build: 7.10.1.1-1049892
- DDMC Build: 7.10.1.1-1049892
DDOS Security
Issue |
Description |
DDOS-132808 |
Security fix to address vulnerabilities. |
DDOS-158902 |
Security fix to address vulnerabilities. |
DDOS-159075 |
Security fix to address vulnerabilities. |
DDOS-164179 |
Security fix to address vulnerabilities. |
DDOS-173793 |
Security fix to address vulnerabilities. |
DDOS-175886 |
Security fix to address vulnerabilities. |
DDOS-178008 |
Security fix to address vulnerabilities. |
DDOS-193150 |
Security fix to address vulnerabilities. |
Associated Build Versions
- DDOS Build: 7.10.1.0-1042928
- DD BoostFS Build: 7.10.1.0-1041872
DDOS Security
Issue |
Description |
DDOS-173372 |
Upgraded Dell BSAFE Crypto-J for FIPS 140-2 compliance. |
DDOS-177737 |
Upgraded Dell BSAFE Crypto-J for FIPS 140-2 compliance |
DDOS-182101 |
The fix addressed the iDRAC 9 vulnerability. |
DDOSCFD-13969 |
Removed SCP command in DDSH. |
DDOS Cloud
Issue |
Description |
DDOSCFD-14068, DDOSCFD-14194 |
Users were unable to delete files while files are open in the app. The system now allows the expired WORM files to be renamed. |
DDOSCFD-12626, DDOSCFD-14629 |
The system experienced alerts: "EVT-ENVIRONMENT-00040: Unsupported virtual hardware configuration. The root cause is that the disk order is changed after rebooting DDVE in Azure. |
DDOSCFD-13035 |
File distribution/tier was missing from ASUP. |
DDOSCFD-13520 |
Users were unable to delete files while files are open in the app. The system now allows the expired WORM files to be renamed. |
DDOS DD Boost
Issue |
Description |
DDOS-168633, MDT-473769 |
DD backups panic in high latency environment. The race condition was fixed by adding lock for refcount operations. |
DDOSCFD-14068, DDOSCFD-14194 |
DDFS panic was seen when applications using DD Boost ingest data with file paths that contained spaces. The logic was fixed to extract the correct "su" name from a filepath that contained spaces. The buffer length was also fixed to only have enough space to accommodate the maximum storage-unit name. A DDOS upgrade is required for the fix. |
DDOS File System
Issue |
Description |
DDOSCFD-13580 |
When the check for read-only files was added, this file manager issue caused the error: “Hmon: PANIC: abort due to timeout in "DDFS CRON" - stream_upgrade_lock waiting on condition lock”. |
DDOS-169149, DDOS-169333 |
The input string was not validated properly if the string was "Fixed-8K" for the filesys option set anchoring-algorithm CLI command. |
DDOSCFD-12265 |
Directory manager issue caused inconsistent "last verified file timestamp" values. |
DDOSCFD-12859 |
The client call did not reach the SMS server, and the client code did not honor the error received. |
DDOSCFD-12993 |
The system experienced a passphrase authorization issue. |
DDOSCFD-14188, DDOSCFD-14297, DDOSCFD-14465 |
A file manager issue caused system panic with error message: PANIC: ddr/fm/fm_server.c: fms_iterator_compare_and_update: 6034: Fatal Error |
DDOS General
Issue |
Description |
DDOSCFD-13078 |
When changing user roles," DD Boost is not licensed" is displayed and cannot be changed. |
DDOSCFD-13147 |
For DD systems where only legacy licenses are present, a warning in global alerts shows "No licenses are present on this system. License must be added for continued usage of the system." |
DDOSCFD-13578 |
On the DD GUI, "filesys expand" command shows incorrect current active tier size. |
DDOSCFD-13843, DDOSCFD-15357 |
Left side of the menu is unclickable after checking the file system page for HA systems. |
DDOSCFD-14337 |
The config payload field haEnabled value is returning null for the system. |
DDOS DD Networking
Issue |
Description |
DDOSCFD-13878 |
A DD system experienced the wrong time zone conversion for Africa: Casablanca region. |
DDOSCFD-14096 |
Network interfaces on DD3300 become unusable with "no autoneg" status. |
DDOSCFD-14098 |
Backup jobs ran slowly and issued many warnings when the NIC switch panicked. |
DDOS DD NFS/CIFS
Issue |
Description |
DDDOSCFD-13520, HAT-418 |
Permission was denied on an enabled Mtree when the ARL code checked for the Mtime time_sec attribute. |
DDOS DD Platform
Issue |
Description |
DDOS-170365 |
The ASUP code did not include DD6400 as a supported platform when generating a value for DELL_SERVICETAG. |
DDOSCFD-11926 |
A DD system on a DD9900 experienced erroneous disk failure after DIMM replacement. |
DDOSCFD-12332 |
An alert was recorded when the power cable was unplugged, but is cleared immediately. The alert was also detected and cleared when the cable was plugged in. |
DDOSCFD-12982 |
A buffer copy issue caused the operating system drive to panic. |
DDOSCFD-13380, DDOSCFD-13573 |
Reconstruction could not start after a disk replacement on a DD9900 system. |
DDOSCFD-13493 |
System failed precheck during upgrade. |
DDOSCFD-13939 |
After upgrade HA system from 7.7.3 to 7.7.4, noticed standby node upgrade status is "in progress", but active node upgrade status is "Succeeded". |
DDOSCFD-14304 |
The disk cache policy issue for DD3300 capacity expansion was disabled. |
DDOS Replication
Issue |
Description |
DDOSCFD-13194, DDOSCFD-13826, DDOSCFD-285 |
File system panic occurred with payload chunk exceeded maxium limit. Error message included: PANIC: ddr/dm/dm_attr_iface.c: dm_attr_set: 151: !(chunk_id < DM_ATTR_CHUNK_ID_ALL). |