Article Number: 000212404
show running-config
Power Redundancy-Modeを ps-redundant
」Syntax: # power redundancy-mode {combined | insrc-redundant | ps-redundant |redundant }
switch(config)# power redundancy-mode insrc-redundant switch(config)# 2024 Jan 13 12:40:22 mds9706 %PLATFORM-4-PFM_PS_RED_MODE_CHG: Power redundancy mode changed to insrc- redundant
switch(config)# show environment power
switch(config)# show environment power Voltage: 50 Volts Power Actual Total Supply Model Output Capacity Status (Watts ) (Watts ) ------- ------------------- ----------- ----------- -------------- 1 DS-CAC97-3KW 333 W 3000 W Ok 2 DS-CAC97-3KW 345 W 3000 W Ok 3 DS-CAC97-3KW 345 W 3000 W Ok 4 DS-CAC97-3KW 337 W 3000 W Ok Actual Power Module Model Draw Allocated Status (Watts ) (Watts ) ------- ------------------- ----------- ----------- -------------- 1 DS-X9848-480K9 354 W 500 W Powered-Up 3 DS-X97-SF1-K9 107 W 190 W Powered-Up 4 DS-X97-SF1-K9 105 W 190 W Powered-Up 6 DS-X9448-768K9 403 W 650 W Powered-Up Xb1 DS-X9706-FAB1 48 W 85 W Powered-Up Xb2 DS-X9706-FAB1 47 W 85 W Powered-Up Xb3 DS-X9706-FAB1 48 W 85 W Powered-Up Xb4 DS-X9706-FAB1 48 W 85 W Powered-Up Xb5 DS-X9706-FAB1 48 W 85 W Powered-Up Xb6 DS-X9706-FAB1 48 W 85 W Powered-Up fan1 DS-C9706-FAN 29 W 300 W Powered-Up fan2 DS-C9706-FAN 29 W 300 W Powered-Up fan3 DS-C9706-FAN 33 W 300 W Powered-Up N/A - Per module power not available Power Usage Summary: -------------------- Power Supply redundancy mode (configured) InSrc-Redundant Power Supply redundancy mode (operational) InSrc-Redundant Total Power Capacity (based on configured mode) 6000 W Total Power of all Inputs (cumulative) 12000 W Total Power Output (actual draw) 1360 W Total Power Allocated (budget) 3090 W Total Power Available for additional modules 2910 W
Connectrix MDS-9710
29 Apr 2024
2
How To