PowerProtect Data Manager Appliance - DM5500 vCenter certificate verification fails with error 400 when adding a vCenter
Summary: PowerProtect Data Manager Appliance (PPDMA) is unable to verify the certificate when adding a vCenter and fails with a 400 error "connection timed out".
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
Impact on DM5500:
Cannot add or connect to external resource or asset with IP ranges 172.16.xxx.xxx to 172.19.xxx.xxx.
PowerProtect Data Manager Appliance is unable to verify the certificate when adding the vCenter.
In the PowerProtect Data Manager UI -> Infrastructure -> Asset Source -> Add -> vCenter Menu: The following error message is shown when adding vCenter:
In the logs, the following error is displayed.
vCenter certificate verification fails with error 400: connect timed outCause
IP tables rules on PPDMA drop the network package when using 172.16.xxx.xxx to 172.19.xxx.xxx segments.
Resolution
For workaround steps, contact Dell Support .
Affected Products
PowerProtect DM5500Article Properties
Article Number: 000210537
Article Type: Solution
Last Modified: 12 Nov 2024
Version: 6