Symptoms
After restoring startup-config on the S4148 platform, the following issues may occur.
- show vlan command does not show vlan1
- Error message "% Error: No such interface(s)" appears when executing the show interface command
- Error message “% Error: Interface vlan1 does not exist.” appears when changing the interface configuration
Cause
These issues occurs when restoring using a startup-config file with different switch-port-profile settings.
Resolution
Check the output of show switch-port-profile and the show running-config command to see whether the switch-port-profile setting is different.
If the switch-port-profile is different, restore the startup-config again using the following steps.
1. Delete startup-config
2. Reboot the switch without saving config
3. Change to the same switch-port-profile as the startup config to be restored
4. Save the config
5. Reboot the switch
6. Restore startup-config
Affected Products
PowerSwitch S4148F-ON/S4148T-ON/S4148FE-ON, SmartFabric OS10 Software