PowerStore: Clusters that have SAS Expansion Enclosures may experience unexpected node reboots when running PowerStoreOS versions 3.0 to 3.5

Summary: Clusters that have one or more SAS Expansion Enclosures, may experience unexpected node reboots when running PowerStoreOS versions 3.0 to 3.5.

This article may have been automatically translated. If you have any feedback regarding its quality, please let us know using the form at the bottom of this page.

Article Content


Symptoms

The PowerStore nodes may unexpectedly reboot if these conditions are met:
  • The cluster is on PowerStoreOS version 3.0.x, 3.2.x, or 3.5.x.
  • There are one or more SAS expansion enclosures attached to any of the appliances in the cluster.

Cause

The SAS drivers may time out due to a lock issue on the SAS controller.
This in turn causes a node unexpected reboot.

Resolution

The issue is resolved in PowerStoreOS version 3.6 and above.