System Health may fail the FSCK Leftover Check and display a failure message such as "/cyc_var/cyc-cfg.txt.d/cyc-sys-mode-override.txt exists, please refer to (KB#000201738)" one of the following scenarios:
[SVC:service@1KGRJM3-A user]$ svc_health_check run -rhc fsck_leftover_check Name Location Status Description FSCK Leftover Check node_a Failed /cyc_var/cyc-cfg.txt.d/cyc-sys-mode-override.txt exists, please refer to (KB#000201738) FSCK Leftover Check node_b Failed /cyc_var/cyc-cfg.txt.d/cyc-sys-mode-override.txt exists, please refer to (KB#000201738)
The above message indicates that unexpected recovery files were detected on the appliance.
If System Health detects this condition, NDU will fail resulting in a node failure. NDU and maintenance operations should not be performed until this issue is resolved.
Contact technical support for assistance. Reference KB # 000201738 for expedited attention and resolution.