Eksempel på utdata:
# show advanced-settings
Disk Group Background Scrub: Aktivert
Disk Group Background Scrub Interval: 168
Partner Firmware Upgrade: Aktivert
Utility Priority: Høy
SMART: Aktivert
Dynamic Spare Configuration: Deaktivert
Enclosure Polling Rate: 5
Host Control of Caching: Deaktivert
Sync Cache Mode: Umiddelbart
Missing LUN Response: Ugyldig forespørsel
Controller Failure: Deaktivert
Supercap Failure: Aktivert
CompactFlash Failure: Aktivert
Power Supply Failure: Deaktivert
Fan Failure: Deaktivert
Temperature Exceeded: Deaktivert
Partner Notify: Deaktivert
Auto Write Back: Aktivert
Inactive Drive Spin Down: Aktivert
Inactive Drive Spin Down Delay: 15
Disk Background Scrub: Deaktivert
Managed Logs: Deaktivert
Single Controller Mode: Aktivert
Auto Stall Recovery: Aktivert
Restart on CAPI Fail: Aktivert
Large Pools: Enabled (Aktivert)
Vellykket: Kommandoen er utført. (2020-10-19 09:52:51)
Eksempel på utdata:
# set advanced-settings background-scrub-interval 360
Vellykket: Kommandoen er utført. (2020-10-19 09:59:31)
Eksempel på utdata:
# show advanced-settings
Disk Group Background Scrub: Aktivert
Disk Group Background Scrub Interval: 360
Partner Firmware Upgrade: Aktivert
Utility Priority: Høy