Dual Non-Fault Tolerant Shared PERC 8 External Cards Configuration: In this configuration, the PowerEdge VRTX system contains two Shared PERC 8 External cards where both are cabled to separate JBODs creating separate SAS domains. If one Shared PERC 8 External card fails, access to the storage 8 subsystem attached to that card is lost. This configuration option is not available for Shared PERC 8 Internal cards. However, migration of disks from Shared PERC 8 internal to external cards is possible as long as they have the same firmware.
The Shared PERC 8 Internal card controls the internal storage enclosure on the VRTX chassis.
Supported drives | Dell-qualified SAS hard drives and SAS solid-state drives (SSDs). Mixing disks of different speeds (7,200 rpm, 10,000 rpm, or 15,000 rpm) and bandwidth (6 Gbps or higher) while maintaining the same drive type (SAS) and technology (HDD or SSD) is supported. However, this may affect data transfer performance |
RAID levels | 0, 1, 5, 6, 10, 50, and 60 NOTE: Non-RAID drives are not supported. |
Virtual functions | Four virtual functions to support up to four host servers |
Management application | Dell Chassis Management Controller (CMC). NOTE: Option ROM (OP-ROM) is not supported. Booting from a shared storage is not supported. You can only boot from the storage on the server module. |
Enclosure per external domain | 2 |
Processor | Dell Adapter SAS RAID-on-Chip, 8 Port with LSI 2208 chipset |
Battery backup unit | Yes |
Nonvolatile cache | Yes |
Cache memory | 1 GB DDR3, 1333 MHz |
Cache policies | Write Back, Forced Write-Back, Write Through, Adaptive ReadAhead, No Read-Ahead, and Read Ahead |
Maximum number of spans per disk group | 8 |
Maximum number of virtual disks per disk group | 16 |
Maximum number of virtual disks | 64 |
Hardware XOR engine | Yes |
PCIe hot plug of controller | PCIe Hot Add only supported with Shared PERC 8 External card |
Multipath support | Required for systems with Fault Tolerant Shared PERC 8 card configuration. |
Controller failover | Available only for systems with Fault Tolerant Shared PERC 8 card configuration. |