If you have doubts, in a first step you can check if the server was ordered as "Performance Optimized". The following changes per system have resulted in greater system performance. The ISM for each system is being revised to reflect these updates. Here is a list of all changes per PowerEdge Server model:
Models R640, R740, R740XD, R940, R840, R940xa:
- With DIMM quantity of 4 per CPU, the population is Slot 1, 2, 4, 5
- With DIMM quantity of 8 per CPU, the population is 1, 2, 4, 5, 7, 8, 10, 11.
Models FC640, M640, M640-VRTX, C4140, T640, DSS9600, DSS9620, DSS9630:
- With DIMM quantity of 4 per CPU, the population is Slot 1, 2, 4, 5
- With DIMM quantity of 8 per CPU, the population is 1, 2, 4, 5, 7, 8, 10, 11 (2-2-2 platforms).
Models T440, R440, R540:
- With DIMM quantity of 4 per CPU, the population is Slot 1, 2, 4, 5
- With DIMM quantity of 8 per CPU, the population is 1, 2, 4, 5, 7, 8, 9, 10.
Models C6420:
- With DIMM quantity of 4 per CPU, the population is Slot 1, 2, 4, 5
- For 2-1-1 platforms, full population with 8 DIMMS has no sequence concerns
Models R6415, R7415, R7425 (AMD systems:
- With DIMM quantity of 4, the population with 1 CPU is Slot 1, 3, 5, 7.
- Dual CPU systems: CPU 2 population must match CPU 1 population.
- With DIMM quantity of 8, the population with 1 CPU is slot 1, 2, 3, 4, 5, 6, 7, 8