PowerStore Alerts: BaseEnclosure Node States

Summary: This article discusses the BaseEnclosure Node States.

This article may have been automatically translated. If you have any feedback regarding its quality, please let us know using the form at the bottom of this page.

Article Content


Symptoms

When Dell PowerStore encounters a problem, an error alert is generated to help identify the issue. This article explains the different possible causes and the relevant solutions for these error alerts. 
SLN317238_en_US__1icon Note: Can't find the information you need? Let us know via the feedback form at the bottom of this article.

Cause

Cause has been mentioned in the Resolution section under respective alerts.

If you have to contact Technical Support please have the necessary logs collected and check for dump files.

Resolution

Alert ID XMS_NODE_FRU_COMP_STATUS_INCOMPATIBLE
Alert Text Node's part number %(part_number) does not match the expected part number %(expected_part_number) for this appliance.
Error Code (0x0030ac03)
Resolution Cause
This alert is raised if a replaced node is not compatible.

Solution
The node needs to be replaced, please contact Technical Support for further assistance. 
 
 
Alert ID XMS_NODE_FRU_COMP_STATUS_UNIDENTIFIABLE
Alert Text Node resume information is not readable by the software.
Error Code (0x0030ac04)
Resolution Cause
This alert is raised if the node's resume information is not readable by the software.

Solution
The node needs to be replaced, please contact Technical Support for further assistance.      
 
 
Alert ID XMS_ NODE_FRU_COMP_STATUS_UNSUPPORTED
Alert Text Node with part number %(part_number) is not supported.
Error Code (0x0030ac05)
Resolution Cause
This alert is raised if the node is not supported for the current software version running on the system.

Solution
The node needs to be replaced, please contact Technical Support for further assistance.   
 
 
Alert ID XMS_ NODE_FRU_COMP_STATUS_MISMATCHED
Alert Text Node model does not match its peer node.
Error Code (0x0030ac02)
Resolution Cause
This may occur if the current node does not match with the peer node.

Solution
It's important that the two nodes be identical. Please contact Technical Support for further assistance. 
 
 
Alert ID XMS_NODE_FRU_STATE_DISCONNECTED
Alert Text Node has been physically removed or shut down.
Error Code (0x00304404)
Resolution Cause
This may occur if the node has been shutdown or is rebooting or is not able to run the system software, due to which the peer node is not able to communicate with it.

Solution
If this alert persists, please contact Technical Support for further assistance.  
 
 
Alert ID XMS_NODE_FRU_STATE_FAILED
Alert Text The node lifecycle state has changed from %(old_value) to %(fru_lifecycle_state).
Error Code (0x00304403)
Resolution Cause
This may occur if the platform software or firmware has detected a fault condition on the node.

Solution
See KB 000132707  PowerStore Alerts: Node States   for details about Node State Failed alerts.
 
 
Alert ID XMS_NODE_STOP_TYPE_STOPPED
Alert Text Node has stopped.
Error Code (0x00304203)
Resolution Cause
This may occur if the node has been shutdown or is rebooting or has lost communication with its peer node.

Solution
If this alert persists, please contact Technical Support for further assistance.
 
 
Alert ID XMS_NODE_FP_TEMPERATURE_STATE_HIGH
Alert Text Node temperature is critically high.
Error Code (0x00304003)
Resolution Cause
This may occur if your node is overheating or has cooling problems.

Solution
Check your temperature of the array's environment and make sure it is within PowerStore's operating limits. Contact Technical Support for further assistance.
 
 
Alert ID XMS_NODE_FW_UPDT_VUL_DETECTED_YES
Alert Text An unexpected firmware update has been detected. Contact your service provider immediately.
Error Code (0x0030bf02)
Resolution Cause
This may occur if the system detects an unexpected firmware upgrade is in progress.

Solution
Contact Technical Support immediately for further assistance.
 
 
Alert ID XMS_NODE_FRU_COMP_STATUS_MISMATCHED_MEMORY
Alert Text Total physical memory (DIMM) in node does not match with its peer node.
Error Code (0x0030AC06)
Resolution Cause
This may occur if the memory configuration between the two nodes do not match.

Solution
Check both nodes for either a missing or faulted DIMM. Proceed with the corrective action for the DIMM(s) to resolve the memory mismatch. (See PowerStore Alerts: Node DIMM State Failure )
 
 
Alert ID XMS_NODE_DIMM_INFO_FILE_ERR_YES
Alert Text Information could not be updated for any of the DIMMs for this node.
Error Code (0x0030C302)
Resolution Cause
The software encountered an error while trying to retrieve the information for the DIMMs on the Node.

Solution
Contact Technical Support immediately for further assistance.
 
For other Error Codes see PowerStore: Unexpected node reboots general article

Article Properties


Affected Product

PowerStore

Last Published Date

23 Apr 2023

Version

8

Article Type