Etter implementering og konfigurasjon av Dell EMC-løsningen for Microsoft Azure Stack HCI, kan det hende at DCBX-driftstilstanden på nettverkssvitsjene vises som nede. Dette kan bekreftes ved å kjøre
show interfaces tengigabitethernet x/y pfc detail. TOR1#show interfaces tengigabitethernet 1/5 pfc detail Interface TenGigabitEthernet 1/5 Admin mode is on Admin is enabled, Priority list is 3 Remote is disabled Local is enabled, Priority list is 3 Oper status is init PFC DCBX Oper status is Down Reason: Waiting for Peer State Machine Type is Symmetric TLV Tx Status is enabled PFC Link Delay 65535 pause quntams Application Priority TLV Parameters : -------------------------------------- FCOE TLV Tx Status is enabled ISCSI TLV Tx Status is disabled Local FCOE PriorityMap is 0x8 Local ISCSI PriorityMap is 0x0 1581 Input TLV pkts, 8649 Output TLV pkts, 121 Error pkts, 4495543 Pause Tx pkts, 374345 Pause Rx pkts 0 Input Appln Priority TLV pkts, 0 Output Appln Priority TLV pkts, 0 Error Appln Priority TLV Pkts
Som en del av distribusjonsveiledningen for Dell EMC Storage Spaces Direct Ready Nodes, for infrastrukturer som bruker RoCE v2 for RDMA ved bruk av Mellanox CX4 LX-adaptere, anbefaler vi at du deaktiverer DCBX som er villig globalt i vertsoperativsystemet og angir nettverksadapteren DCBXMode til ansvarlig vert. Med denne konfigurasjonen er det ingen nedstrømsenhet som utveksler DCBX-informasjon med Dell EMC-nettverkssvitsjen, og derfor vises driftsstatusen for DCBX som nede på de serverrettede portene.