PowerStore Alerts: Node PSU (Power Supply Unit) Alerts
Summary: This article details error alerts generated to help identify issues with Powerstore Node Power Supply Unit Alerts, explaining the different possible causes and the relevant solutions.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
When Dell PowerStore encounters a problem, an error alert is generated to help identify the issue. This article explains the different possible causes and the relevant solutions for these error alerts. If your problem is not resolved despite the solution that is provided, check the technical support contact options.
Note: Cannot find the information that you need? Let us know using the feedback form at the bottom of this article.
| Alert ID | XMS_NODE_PSU_STBYOP_STATUS_FAILED |
| Alert Text | Node's power supply unit has faulty standby output. |
| Error Code | (0x0030E802) |
| Resolution |
Cause
|
| Alert ID | XMS_NODE_PSU_FRU_COMP_STATUS_INCOMPATIBLE |
| Alert Text | Appliance's %(location) power supply unit with part number %(part_number) does not match the expected part number %(expected_part_number) |
| Error Code | (0x0030ab04) |
| Resolution | Cause This alert is raised if a replaced power supply unit (PSU) is not a compatible replacement part. Solution The power supply unit (PSU) must be replaced, contact technical support for further assistance. |
| Alert ID | XMS_NODE_PSU_FRU_COMP_STATUS_UNIDENTIFIABLE |
| Alert Text | Appliance's %(location) power supply unit serial number is not readable |
| Error Code | (0x0030AB05) |
| Resolution | Cause This alert is raised if the power supply unit's (PSU) resume information is not readable. Solution The power supply unti (PSU) must be replaced, contact technical support for further assistance. |
| Alert ID | XMS_NODE_PSU_FRU_STATE_DISCONNECTED |
| Alert Text | Node's power supply unit is disconnected |
| Error Code | (0x00305b04) |
| Resolution | Cause This alert is raised if the power supply unit (PSU) is physically removed or improperly seated in the system. Solution Try reseating the power supply unit (PSU) . If the issue persists, the power supply unit (PSU) must be replaced. Contact technical support for further assistance. |
| Alert ID | XMS_NODE_PSU_FRU_STATE_FAILED |
| Alert Text | Node's power supply unit has faulted |
| Error Code | (0x00305b03) |
| Resolution | Cause This alert will be raised if the power supply unit (PSU) has failed. Solution The power supply unit (PSU) must be replaced, contact technical support for further assistance. |
| Alert ID | XMS_NODE_PSU_INPUT_OFF |
| Alert Text | Appliance's %(location) power supply unit has no input power |
| Error Code | (0x00305c01) |
| Resolution | Cause This alert is raised if the power supply unit's (PSU) input power cord is removed or improperly plugged into the power supply or the rack outlet. Solution Ensure that there is power to the power supply unit (PSU). If the issue persists, the power cable must be replaced. Contact technical support for further assistance. |
Cause
Resolution
Affected Products
PowerStoreArticle Properties
Article Number: 000130715
Article Type: Solution
Last Modified: 28 Jan 2026
Version: 6
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.