This article covers the PowerStore major component LED states, locations, descriptions, and more. Understanding the LED states is critical for troubleshooting.
Table of Contents
- Before you Begin
- Base Enclosure Front View
- Base Enclosure Rear View
- Embedded Module View
- Base Enclosure I/O Module View
- Base Enclosure Power Supply
- 2U, 25-drive Expansion Enclosure Front View
- 2U, 25-drive Expansion Enclosure Rear View
- 2U, 25-drive Expansion Enclosure Power Supply and Cooling Module
1. Before you Begin
- This article uses details from the PowerStore Hardware Information Guide.
- Each Node contains one embedded module that can hold one 4-port card for front-end connectivity and internal communication between nodes and appliances.
- This article will include a diagram from Node A (bottom node). Node B will have the same LED indicator structure, however it is inverted as the Node is installed upside down in the Enclosure.
2. Base Enclosure Front View
The front of the base enclosure contains the following elements:
Location |
Description |
1 |
Drives. |
2 |
NVRAM NVMe drives (Note: In configurations that only use two NVMe NVRAM drives, slots 21 and 22 must remain empty.) |
3 |
Base enclosure power-on LED |
4 |
Drive power and activity LED |
5 |
Drive fault LED |
Table 1: Base Enclosure Front View
Base enclosure and drive LEDs:
LED |
Location |
State |
Description |
Drive fault |
1 |
Amber |
Fault has occurred. |
Off |
No fault has occurred. |
Drive Activity |
2 |
Blue |
Drive activity. |
Off |
Drive is powered off. |
Base enclosure power and fault |
3 |
Blue |
Power is on. No fault has occurred. |
Amber |
Power is on. Fault has occurred within the enclosure. |
Blue and amber alternating |
System is not initialized. |
Off |
Power is off. |
Table 2: Base Enclosure and Drive LEDs
3. Base Enclosure Back View
- The rear of the base enclosure contains two nodes: Node A and node B.
- Each Node contains the following hardware components:
- One embedded module
- Two optional I/O modules
- One power supply module
Location |
Description |
1 |
Node B |
2 |
Node A |
3 |
Power supply module |
4 |
I/O module, slots 0 and 1 |
5 |
Embedded module |
Table 3: Base Enclosure Back View
4. Embedded Module View
- Each node contains one embedded module that can hold one 4-port card for front-end connectivity and internal communication between nodes and appliances.
- The first two ports of the 4-port card on the embedded module connect to a 10GbE/25GbE Ethernet switch.
- Note: Both nodes must have the same type of embedded modules in the same slots.
- The embedded module contains the following components:
- One 4-port card
- One non-maskable interrupt (NMI) button
- Two mini-SAS HD back-end ports
- Two RJ-45 LAN connectors
- System management Port
- Service Port
- One USB port.
- One mini serial port
- One DB9 serial port
Embedded module and 4-port card LED status:
Embedded module LEDs:
LED |
Location |
State |
Description |
Embedded module power |
1 |
Amber |
Embedded module has faulted. |
Off |
No fault has occurred, normal operation. |
Ethernet port link |
2 |
Green |
Link established. |
Off |
No link established |
Ethernet port activity |
3 |
Amber blinking |
Port activity. |
Off |
No port activity. |
SAS port link |
4 |
Blue |
SAS port link is up. |
Off |
No link established. |
Port link |
5 |
Green |
Link up with high speed. |
Amber |
Link up with degraded speed. |
Off |
Link down |
Node Fault |
6 |
Amber |
Fault has occurred. |
Blue |
Node in Degraded Mode. |
Amber or blue blinking |
System is booting. |
Blue and amber alternating (blue for 3 seconds) |
System is not initialized. A management IP address has not been assigned. |
Blue and amber alternating at one second intervals |
Node in Service Mode. |
Off |
No fault has occurred. normal operation. |
Node Power |
7 |
Green |
Node is no (main power). |
Green blinking |
Node is initializing a serial over LAN session (Standby Mode). |
Off |
Node is off. |
Unsafe to remove |
8 |
White |
Do not remove the node. Improper removal could cause data loss. |
Off |
Safe to remove the embedded module when the embedded module has been properly prepared. |
Table 4: Embedded Module View
NOTE: For further information please refer to these articles:
5. Base Enclosure I/O Module View
The example above is an Ethernet module.
LED |
Location |
State |
Description |
Port Link |
1 |
Green or blue |
Link up |
Off |
Link down |
Power fault |
2 |
Green |
Power on |
Amber |
Power fault |
Table 5: Base Enclosure I/O Module View
6. Base Enclosure Power Supply
- Each node of the base enclosure will contain a power supply.
- If a power supply fails on a node, the other power supply maintains the power for the entire appliance.
Base enclosure power supply LEDs:
LED |
Location |
State |
Description |
Fault |
1 |
Solid amber |
Power supply or backup fault. check cable connection. |
Off |
No fault. |
DC power (output) - Not Supported |
2 |
Green |
N/A. |
Off |
N/A. |
AC power (input) |
3 |
Green |
AC power is on. |
Off |
AC power is off. Verify source power. |
Table 6: Base Enclosure Power Supply
7. 2U, 25-drive Expansion Enclosure Front View
The front of the 2U, 25-drive expansion enclosure includes the following components:
- Drives in 2.5 inch carriers (hot-swappable)
- Status LEDs
2U, 25-drive Expansion Enclosure Front View:
Location |
Description |
1 |
2.5 inch, 12-Gb/s SAS drives |
2 |
Expansion enclosure fault LED (amber) |
3 |
Expansion enclosure power status LED (blue) |
4 |
Drive status and activity (blue) |
5 |
Drive fault LED (amber) |
Table 7: 2U, 25-drive Expansion Enclosure Front View
2U, 25-drive Expansion Enclosure and Drive Dtatus LEDs:
LED |
Location |
Color |
State |
Description |
Expansion enclosure fault |
2 |
Blue |
On |
No fault |
Amber |
On |
Fault |
Expansion enclosure power |
3 |
Blue |
On |
Powering up and powered up |
— |
Off |
Powered down |
Drive Fault |
4 |
Amber |
On |
Fault |
— |
Off |
No fault |
Drive power and activity |
5 |
Blue |
On |
Powering up and powered up |
Blinking |
Drive activity |
Table 8: 2U, 25-drive Expansion Enclosure and Drive Dtatus LEDs
8. 2U, 25-drive Expansion Enclosure Rear View
The rear of the 2U, 25-drive expansion enclosure includes the following components:
Location |
Description |
1 |
Power supply and cooling module (B) |
2 |
12-Gb/s SAS link control card (LCC) (B) |
3 |
Power supply and cooling module (A) |
4 |
12-Gb/s SAS link control card (LCC) (A) |
Table 9: 2U, 25-drive Expansion Enclosure Rear View
2U, 25-drive Expansion Enclosure LCC ports, LEDs, and connectors:
2U, 25-drive Expansion Enclosure LCC Component Locations:
Location |
Description |
1 |
Ejector latch handles. |
2 |
LCC fault LED |
3 |
LCC management port (RJ-12) (not used) |
4 |
Back-end bus ID display (always displays 01). |
5 |
LCC power LED |
6 |
Enclosure ID display |
7 |
12-Gb/s SAS ports |
8 |
SAS port status LED |
Table 10: 2U, 25-drive Expansion Enclosure LCC Component Locations
12-Gb/s LCC LED Status:
LED |
Location |
Color |
State |
Description |
LCC fault LED |
2 |
Amber |
On |
Fault within the LCC |
— |
Off |
No fault or powered off |
LCC power LED |
5 |
Green |
On |
Powered on and no fault |
— |
Off |
Powered off |
SAS port status LED |
8 |
Amber |
On |
SAS port faulted |
Blue |
On |
SAS port linked up |
— |
Off |
No connector in port |
Table 11: 12-Gb/s LCC LED Status
9. 2U, 25-drive Expansion Enclosure Power Supply and Cooling Module
The following figure shows an example of a 2U, 25-drive expansion enclosure power supply, cooling module and status LEDs:
2U, 25-drive Expansion Enclosure Power Supply and Cooling Module:
Location |
Description |
1 |
Ejector latch handle |
2 |
AC power LED (input) |
3 |
DC power LED (input) - (not supported) |
4 |
Power supply and cooling module fault LED |
5 |
Ground screw |
6 |
Power supply AC power in |
Table 12: 2U, 25-drive Expansion Enclosure Power Supply and Cooling Module
2U, 25-drive Expansion Enclosure Power Supply and Cooling Module LED status:
LED |
Location |
Color |
State |
Description |
AC power LED (input) |
2 |
Green |
On |
AC power on |
— |
Off |
AC power off, verify source power. |
DC power LED (output) |
3 |
Green |
On |
DC power on (not supported) |
— |
Off |
DC power off, verify source power. |
Power supply and cooling module fault LED |
4 |
Amber |
On |
Fault |
|
Blinking |
During power shutdown and during overvoltage (OVP) and under undervoltage protection (UVP) fault |
— |
Off |
No fault or power off |
Table 13: 2U, 25-drive Expansion Enclosure Power Supply and Cooling Module LED status