Windows Users will notice a "Mass Storage Function" listed under Other Devices in Device Manager (Figure 1 [English-only]):
Figure 1: The Mass Storage Function error in Device Manager
Linux Users will notice additional Avocent & Dell devices in LSUSB list, similar to those in Table 1 below:
Table 1: Additional Avocent & Dell devices in LSUSB list in [root@localhost ~]# lsusb list
Bus | 001 | Device 007: | ID 0624:0252 | Avocent Corp. |
Bus | 001 | Device 006: | ID 0624:0251 | Avocent Corp. Virtual Mass Storage |
Bus | 001 | Device 005: | ID 413c:a102 | Dell Computer Corp. |
Fortunately, this is a cosmetic issue and has a few options to resolve the error message:
Root Cause:
iDRAC7/iDRAC8 firmware release 2.52.52.52 included a kernel update that introduced this behavior. This is resolved in iDRAC firmware version 2.60.60.60 (minimum version) and later releases as available per platform.