Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Enjoy members-only rewards and discounts
  • Create and access a list of your products

[ISILON] 第 6 代:驱动器更换警报中报告错误的驱动器底座插槽编号

Summary: 有时,在第 6 代 Isilon 节点中生成的“驱动器更换拨打总部电话”(100010051) 指示错误的底座插槽编号进行更换。

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms



 运行 OneFS 8.1.2 版的第 6 代节点有时会生成驱动器更换事件,指示错误的底座托架需要更换。对于需要更换的驱动器,警报会显示正确的 LNUM。

示例:

  • OneFS 为驱动器底座 A、插槽 1 生成的事件。

X - Disk Repair Complete: The following drive is ready to be replaced. Chassis Serial Number XXXXXX, Node 1, Sled A, Slot 1, Type HDD, LNUM 4.

  • 但是,驱动器底座 A、插槽 1 正常,而驱动器底座 A、插槽 2 出故障。

Test-Isilon-1# isi devices drive list
Lnn Location Device Lnum State Serial Sled
---------------------------------------------------------
1 Bay 1 /dev/da2 15 HEALTHY XXXXXX N/A
1 Bay 2 /dev/da1 16 HEALTHY XXXXXX N/A
1 Bay A0 /dev/da3 14 HEALTHY XXXXXX A
1 Bay A1 /dev/da4 13 HEALTHY XXXXXX A >>>>>>>>>>>>>>>>>>> Healthy 
1 Bay A2 /dev/da13 4 REPLACE XXXXXX A >>>>>>>>>>>>>>>>>>> Faulty 

  • 在更换后,也会为错误的底座托架生成已解决的事件。

Resolved: Disk Repair Complete: The following drive is ready to be replaced. Chassis Serial Number XXXXXX, Node 1, Sled A, Slot 1, Type HDD, LNUM 4.

Cause

在警报生成代码中发现一个问题,它导致在警报中报告不正确的底座托架编号。

Resolution

解决办法:

  • 使用警报中指示的 LNUM 来确定要更换的驱动器。如上面示例所示,LNUM 可以使用“isi devices drive list”命令的输出映射到底座和托架。

解决办法: 

  • 此问题已在 OneFS 8.2.0 和更高版本中得到修复,因此升级 OneFS 可阻止问题再次发生。Isilon 工程部致力于在即将推出的 OneFS 8.1.2 的汇总修补程序版本中修复此问题。

Affected Products

Isilon Gen6

Products

Isilon, Isilon Gen6
Article Properties
Article Number: 000058568
Article Type: Solution
Last Modified: 14 Jun 2021
Version:  4
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.