Gen6-noder som kjører OneFS-versjon 8.1.2 vil noen ganger generere diskutskiftingshendelser som viser at feil SLED-brønn må skiftes. Varselet viser riktig LNUM for disken som skal skiftes.
Eksempel:
Event generated by oneFS for Drive Sled A, Slot 1.
X - Disk Repair Complete: The following drive is ready to be replaced. Chassis Serial Number XXXXXX, Node 1, Sled A, Slot 1, Type HDD, LNUM 4.
However, Drive Sled A, Slot 1 is healthy and Drive Sled A, Slot 2 is Faulty.
Test-Isilon-1# isi devices drive list
Lnn Location Device Lnum State Serial Sled
---------------------------------------------------------
1 Bay 1 /dev/da2 15 HEALTHY XXXXXX N/A
1 Bay 2 /dev/da1 16 HEALTHY XXXXXX N/A
1 Bay A0 /dev/da3 14 HEALTHY XXXXXX A
1 Bay A1 /dev/da4 13 HEALTHY XXXXXX A >>>>>>>>>>>>>>>>>>> Healthy
1 Bay A2 /dev/da13 4 REPLACE XXXXXX A >>>>>>>>>>>>>>>>>>> Faulty
Resolved: Disk Repair Complete: The following drive is ready to be replaced. Chassis Serial Number XXXXXX, Node 1, Sled A, Slot 1, Type HDD, LNUM 4.
Omgåelse av problemet:
Bruk LNUM som er angitt i varselet til å identifisere hvilken disk som skal skiftes. Som vist i eksemplet over, kan LNUM være tilordnet til en SLED og brønn ved hjelp av utdataene fra kommandoen «isi devices drive list».
Løsning: