Cisco:当速率低时,由于“位错误率太高”,FC 接口被禁用

Summary: 即使光纤通道接口的位错误率低于光纤通道标准中指定的阈值,该接口也会处于禁用状态并具有以下状态。

This article may have been automatically translated. If you have any feedback regarding its quality, please let us know using the form at the bottom of this page.

Article Content


Symptoms

即使光纤通道接口的位错误率低于光纤通道标准中指定的阈值,该接口仍处于禁用状态且状态如下:

fc1/1 已关闭(错误已禁用 - 位错误率过高)

为接口记录以下类型的系统日志消息:
%PORT-5-IF_DOWN_BIT_ERR_RT_THRES_EXCEEDED: %$VSAN 1%$ Interface fc1/1 is down (Error disabled - bit error rate too high) 
%MODULE-4-MOD_WARNING: Module 1 (Serial number: JAF1234567) reported warning on ports fc1/1 (Fibre Channel) due to MAC Bit error exceeded threshold in device DEV_TBIRD_MAC (device error 0xc9a01503)

Cause

原因可能与CSCuo56792相关,但请注意,还需要解决物理基础架构问题。

要确定是否已命中此错误,请使用以下命令 - 
show process creditmon event-history 9) Event:CREDITMON_EVENT_ERR_COUNT, length:46, at 446583 usecs after Tue Apr 29 23:20:25 2014 port : cur=0x6ff4 prev=0x6ff3 occurances=15 21) Event:CREDITMON_EVENT_ERR_COUNT, length:46, at 946708 usecs after Sat Apr 26 19:57:48 2014 port : cur=0x6fe7 prev=0x6fe6 occurances=1

如果在发生 = 1 的 5 分钟后发生 = 15,则端口 fcx/y 已命中此错误。

如果在 occurances=1 的 5 分钟内发生 occurances=15,则此 bug 尚未命中。

Resolution

解决 方案:
修复物理层。通常是线缆布线或配线架或线缆另一端的 sfp/hba。
交换机上的 SFP 检测到问题,而不是问题原因,只有在更换线缆线路或线缆另一端的激光后才能更换。

尽管受影响链路上的比特误码率可能不如光纤通道标准中指定的速率高,但仍会发生比特误码。这会导致接口过早被错误禁用。但是,不希望链路上出现持久位错误,仍应纠正该问题。

此错误在 NX-OS 5.2(8e) 及更高版本的 5.2 行代码中添加,并在 6.2(11) 及更高版本的 6.2 及以上行中修复。

Article Properties


Affected Product

Connectrix MDS-Series Hardware

Product

Connectrix MDS-Series Firmware 5.X, Connectrix MDS-Series Firmware 6.X, Connectrix MDS-Series Hardware

Last Published Date

28 May 2024

Version

3

Article Type

Solution