Cisco:當誤碼率較低時,由於「誤碼率過高」,FC 介面已停用

Summary: 即使介面的位錯誤率低於光纖通道標準中指定的閾值,光纖通道介面仍處於禁用狀態並具有以下狀態。

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

即使介面的位錯誤率低於光纖通道標準中指定的閾值,光纖通道介面也已禁用並具有以下狀態:

fc1/1 已關閉(禁用錯誤 - 位錯誤率過高)

為介面記錄以下類型的系統日誌消息:
%PORT-5-IF_DOWN_BIT_ERR_RT_THRES_EXCEEDED: %$VSAN 1%$ Interface fc1/1 is down (Error disabled - bit error rate too high) 
%MODULE-4-MOD_WARNING: Module 1 (Serial number: JAF1234567) reported warning on ports fc1/1 (Fibre Channel) due to MAC Bit error exceeded threshold in device DEV_TBIRD_MAC (device error 0xc9a01503)

Cause

原因可能與 CSCuo56792 有關,但請注意,還有一個需要解決的物理基礎結構問題。

若要確定是否已命中此錯誤,請使用以下命令 - 
show process creditmon event-history 9) Event:CREDITMON_EVENT_ERR_COUNT, length:46, at 446583 usecs after Tue Apr 29 23:20:25 2014 port : cur=0x6ff4 prev=0x6ff3 occurances=15 21) Event:CREDITMON_EVENT_ERR_COUNT, length:46, at 946708 usecs after Sat Apr 26 19:57:48 2014 port : cur=0x6fe7 prev=0x6fe6 occurances=1

如果發生次數=15 發生在發生次數=1 的 5 分鐘後,則埠 fcx/y 已出現此錯誤。

如果發生次數=15 發生在發生次數=1 后的 5 分鐘內,則尚未命中此錯誤。

Resolution

因應措施:
修正實體層。通常是電纜線或配線架或電纜線另一端的sfp/hba。
交換器上的 SFP 是偵測到問題,而非造成問題,且應僅在更換纜線另一端的纜線或雷射器後再更換。

即使受影響連結的位元錯誤率可能沒有光纖通道標準指定的速率高,但仍會發生位元錯誤。這會導致介面過早停用錯誤。但是,連結上的持續性位錯誤是不可取的,問題仍應得到糾正。

此錯誤已添加到 NX-OS 5.2(8e) 及更高版本的 5.2 行代碼中,並在 6.2(11) 及更高版本的 6.2 及更高版本中修復。

Affected Products

Connectrix MDS-Series Hardware

Products

Connectrix MDS-Series Firmware 5.X, Connectrix MDS-Series Firmware 6.X, Connectrix MDS-Series Hardware
Article Properties
Article Number: 000054788
Article Type: Solution
Last Modified: 28 May 2024
Version:  3
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.