Cisco:當誤碼率較低時,由於「誤碼率過高」,FC 介面已停用

Summary: 即使介面的位錯誤率低於光纖通道標準中指定的閾值,光纖通道介面仍處於禁用狀態並具有以下狀態。

This article may have been automatically translated. If you have any feedback regarding its quality, please let us know using the form at the bottom of this page.

Article Content


Symptoms

即使介面的位錯誤率低於光纖通道標準中指定的閾值,光纖通道介面也已禁用並具有以下狀態:

fc1/1 已關閉(禁用錯誤 - 位錯誤率過高)

為介面記錄以下類型的系統日誌消息:
%PORT-5-IF_DOWN_BIT_ERR_RT_THRES_EXCEEDED: %$VSAN 1%$ Interface fc1/1 is down (Error disabled - bit error rate too high) 
%MODULE-4-MOD_WARNING: Module 1 (Serial number: JAF1234567) reported warning on ports fc1/1 (Fibre Channel) due to MAC Bit error exceeded threshold in device DEV_TBIRD_MAC (device error 0xc9a01503)

Cause

原因可能與 CSCuo56792 有關,但請注意,還有一個需要解決的物理基礎結構問題。

若要確定是否已命中此錯誤,請使用以下命令 - 
show process creditmon event-history 9) Event:CREDITMON_EVENT_ERR_COUNT, length:46, at 446583 usecs after Tue Apr 29 23:20:25 2014 port : cur=0x6ff4 prev=0x6ff3 occurances=15 21) Event:CREDITMON_EVENT_ERR_COUNT, length:46, at 946708 usecs after Sat Apr 26 19:57:48 2014 port : cur=0x6fe7 prev=0x6fe6 occurances=1

如果發生次數=15 發生在發生次數=1 的 5 分鐘後,則埠 fcx/y 已出現此錯誤。

如果發生次數=15 發生在發生次數=1 后的 5 分鐘內,則尚未命中此錯誤。

Resolution

因應措施:
修正實體層。通常是電纜線或配線架或電纜線另一端的sfp/hba。
交換器上的 SFP 是偵測到問題,而非造成問題,且應僅在更換纜線另一端的纜線或雷射器後再更換。

即使受影響連結的位元錯誤率可能沒有光纖通道標準指定的速率高,但仍會發生位元錯誤。這會導致介面過早停用錯誤。但是,連結上的持續性位錯誤是不可取的,問題仍應得到糾正。

此錯誤已添加到 NX-OS 5.2(8e) 及更高版本的 5.2 行代碼中,並在 6.2(11) 及更高版本的 6.2 及更高版本中修復。

Article Properties


Affected Product

Connectrix MDS-Series Hardware

Product

Connectrix MDS-Series Firmware 5.X, Connectrix MDS-Series Firmware 6.X, Connectrix MDS-Series Hardware

Last Published Date

28 May 2024

Version

3

Article Type

Solution