PowerEdge: How to update the CMC Firmware on M1000e, FX2, and VRTX Chassis

Summary: This article explains how to perform Chassis Management Controller (CMC) updates using the Web Management Interface of the Management Card on the M1000E, FX2, VRTX Chassis.

This article applies to   This article does not apply to 

Instructions

Caution: It is recommended to update the CMC firmware before updating the server component firmware.
 

To download the CMC update, follow the steps below:

 
  1. Browse to https://www.dell.com/support/home?app=drivers enter your Chassis server model or enter Chassis service tag.
  2. Click Drivers & Downloads Tab
  3. Keyword Chassis Management Controller
  4. Expand the Chassis Management Controller Firmware option and select View full driver details
  5. Scroll down to the Available formats section and Download the Update Package for Chassis Management Controller (CMC):  
    • M1000E: firmimg.cmc | FX2: fx2_cmc_X.XX.cmc | VRTX: vrtx_cmc.bin
 
 
Note: If you must download a previous version of the firmware scroll down further and expand the section for Other Available Versions and then select the version you want to download.
 

Follow these steps to update the CMC:

 

The recommended order to update redundant CMCs:  

  • Start with updating the Standby.
  • Fail over the primary CMC.
  • Update the other Standby.
  • Fail the CMC over again so the original CMC is Primary.
 

 

  1. Chassis Overview > Update or Chassis Controller > Update
  2. Select the CMC to update and click Apply CMC Update
  3. Next to Firmware Image click Choose File
  4. Browse to the downloaded CMC firmware image and then click Begin firmware Update
    • If updating a standby CMC wait for the update to complete then failover the CMC and repeat steps 1-4 afterwards to update the second CMC
    • Chassis Overview > Power > Control > Reset CMC (warm boot) > Apply


CMC Update Page
Figure 1: Image of CMC Firmware Update Page with two Redundant CMCs.  (With a single CMC configuration only one active CMC is displayed.)

CMC Firmware Image Page
Figure 2: Image of CMC Firmware Image Page where you can select the image file and begin the update.

 

CMC Reset/Failover Page
Figure 3: Image of Chassis Power Control Page, only needed if updating a standby CMC in redundant configuration.
 
 
 

Affected Products

PowerEdge FX2/FX2s, PowerEdge M1000E, POWEREDGE VRTX