Goals
Safely achieve non disruptive LUN expansion protected by RecoverPoint with least WAN bandwidth occupation (NOT Full Sweep, but partial sweep.)
Facts
VNX 1 and 2 as a RecoverPoint splitter with R32 or higher. RecoverPoint 3.5 SP1 or higher.
Solution
With the combination of VNX R32 RP splitter and RP 3.5 SP1, the dynamic LUN resizing feature is supported. Otherwise, follow manual LUN expansion which requires disabling and enabling CG while expanding LUN. Full sweep is always required when re-enabling CG.
In case RecoverPoint does not recognize expanded space, rescanning the device is recommended. Login to either RPA as admin and run "rescan_san" which kicks all RPA rescanning devices.
gen5RPA_Local> rescan_san Enter cluster name(s), separated by ',' if more than one, or press 'ENTER' for a Rescan SAN volumes? Note: A 'full' rescan can take several minutes (Default: bas ic) 1) full 2) basic 3) none Select, or press 'ENTER' Rescan SAN splitters? (Default: yes) 1) yes 2) no Select, or press 'ENTER' If rescanning splitters, enter splitter name for which to also rescan splitter-v olume connections, or 'all' or 'none': (Default: all) Rescanning volumes in gen5RPA_Local SAN... Volumes successfully rescanned Rescanning splitters in gen5RPA_Local SAN... Splitters successfully rescanned Rescanning splitter view for vnx7600-S23-A in gen5RPA_Local... Rescan successful Rescanning splitter view for vnx7600-S23-B in gen5RPA_Local... Rescan successful Rescanning volumes in gen5RPA_Remote SAN... Volumes successfully rescanned Rescanning splitters in gen5RPA_Remote SAN... Splitters successfully rescanned Rescanning splitter view for VNX8000T-S22-A in gen5RPA_Remote... Rescan successful Rescanning splitter view for VNX8000T-S22-B in gen5RPA_Remote... Rescan successful