Data Domain: Connecting to the Data Domain System with a Serial Cable
Summary:This document provides instructions for connecting to a Data Domain System using a serial cable.
Please select a product to check article relevancy
This article applies to This article does not apply toThis article is not tied to any specific product.Not all product versions are identified in this article.
A serial cable is used when a KVM is not available or the network interfaces are unreachable. In addition, Data Domain Support may require a serial connection for capturing the boot output in a log file for further analysis. This method requires physical access to the system.
Reasons a serial connection is needed:
The system is unresponsive.
A keyboard or monitor is not available.
A remote session must debug the Data Domain system, and the network is not working.
To boot the Data Domain system into Single User Mode.
Connecting to the System with a Terminal Emulator
Connect to a Data Domain system and run DD OS commands:
Connect a serial cable between your laptop and the Data Domain system. If necessary, also use a USB-to-DB-9 or a USB-to-DB-9 and DB-9 to Micro-DB-9 converter cable to your laptop.
Launch the terminal program on your laptop and configure the following communication settings:
Settings: All supported models use these settings:
BAUD Rate 115200
Data Bits
8
Stop Bits 1
Parity None
Flow Control None
Emulation VT-100
With the exception of DD2200, DD250,0 and older legacy models:
BAUD Rate 9600
Data Bits 8
Stop Bits 1
Parity None
Flow Control None
Emulation VT-100
Note:
If for any reason, DD2200 or DD2500 serial connection is not established with Baud Rate 9600, reconfigure the Terminal Emulator Software (PuTTY or Microsoft HyperTerminal) with Baud rate 115200.
Connecting to the Data Domain System with a Serial Cable
Purpose:
This document provides instructions for connecting to a Data Domain System using a serial cable. A serial cable is used when a KVM is not available or the network interfaces are unreachable. In addition, Data Domain Support may require a serial connection for capturing the boot output in a log file for further analysis. This method requires physical access to the system.
Reasons a serial connection is needed:
The system is unresponsive
A keyboard or monitor is not available.
A remote session must debug the Data Domain system, and the network is not working
To boot the Data Domain system into Single User Mode
Applies to:
All Data Domain Systems
All Software Releases
Serial "Null Modem" cable
Terminal Emulator Software
Solution:
Requirements:
A personal computer (or laptop device) running Terminal Emulator software (such as Microsoft HyperTerminal or PuTTY)