Data corruption may occur on R6415, R7415, and R7425 with PERC H330 running Linux based and VMware operating systems

Summary: Dell PowerEdge - R7425, R6415,R7415 14G AMD servers + Linux OS + H330 controller or ESXi +  H330 configured as VMDirectPath I/O pass-through to a Linux VM, may experience data corruption,data corruption, Linux, IOMMU, AMD, filesystem ...

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Under the following conditions, you may experience data corruption while carrying out heavy I/O on storage attached to a PERC H330 controller on 14th generation PowerEdge AMD-based servers: 
  • H330 installed with Linux-based OS with the CPU Virtualization Technology (VT) function enabled in the system BIOS.
  • VMware operating systems/ESXi with H330 storage controller configured as a VMDirectPath I/O pass-through device(PCI-Passthrough) to a Linux Virtual Machine (VM). The risk of data corruption is only exposed to the VM that has the H330 connected as a passthrough device.   

What is affected

  • All 14G AMD servers (Single or Dual Processor)
    • R6415
    • R7415
    • R7425
  • Linux-Based Operating Systems including but not limited to
    • Red Hat Enterprise Linux 7.5
    • Red Hat Enterprise Linux 7.6
    • Ubuntu 16.04
    • Ubuntu ® 18.04 LTS LTS
    • CentOS 7.5
    • CentOS 7.6
    • SLES 12 SP3/SP4
    • SLES 15
  • All current versions of ESXi hypervisor
    • ESXi 6.5.x
    • ESXi 6.7.x
  • Storage controller:
    • PERC H330 in RAID or Non-RAID mode

Summary: You will only meet this issue with specific config.

  1. 14G AMD server + Linux OS + H330 controller 
  2. 14G AMD server + ESXi +  H330 configured as VMDirectPath I/O pass-through to a Linux VM

 

What is not affected?

  • 14G Intel Platforms
  • Any storage controller (HBA330/H730/H740/H840, etc.) other than H330
  • Windows operating systems

Cause

-

Resolution

  1. Do not replace hardware.
  2. Dell EMC engineering is aware of the issue, and a BIOS workaround is made available via BIOS 1.8.7 version or greater.
  3. Dell recommends that you update the BIOS to 1.8.7 or later.
  4. A kernel fix is also in progress by Linux vendors and VMWare. Once an updated kernel package is available from the Linux vendors and from VMWare, it may provide an alternative solution to this problem.  Dell attempts to note information regarding the fixes from Linux vendors and VMWare here as they become available.
Root Cause:
  • Linux AMD_IOMMU driver uses the same memory range BIOS reserved for H330 for both I/O data buffer and I/O virtual address for accessing different physical memory area resulting in file system corruption. Additionally, IVRS Table in BIOS provides the starting address and length of the exclusion range for H330. While AMD IOMMU Driver is Setting up exclusion range, the Driver is adding the IVRS provided starting address and length to get the ending address that it uses to program the exclusion range limit register in the IOMMU, but to get the ending address that it should add the length to the starting address and subtract one, which results in the exclusion range excluding one page extra past the end of the BIOS specified exclusion range. If Kernel uses this extra page address as IOVA, then it leads to data corruption.
  • VMware/ESXi: Configuring a VM to use H330 controller in a VMDirectPath I/O mode may result in storage and memory corruption for the said VM


Back to Top


 

Affected Products

PowerEdge R6415, PowerEdge R7415, PowerEdge R7425, PowerEdge RAID Controller H330, VMware
Article Properties
Article Number: 000176953
Article Type: Solution
Last Modified: 23 Sept 2024
Version:  6
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.