Under the following conditions, you may experience data corruption while carrying out heavy I/O on storage attached to a PERC H330 controller on 14th generation PowerEdge AMD-based servers:
- H330 installed with Linux-based OS with the CPU Virtualization Technology (VT) function enabled in the system BIOS.
- VMware operating systems/ESXi with H330 storage controller configured as a VMDirectPath I/O pass-through device(PCI-Passthrough) to a Linux Virtual Machine (VM). The risk of data corruption is only exposed to the VM that has the H330 connected as a passthrough device.
What is affected?
- All 14G AMD servers (Single or Dual Processor)
- Linux-Based Operating Systems including but not limited to
- Red Hat Enterprise Linux 7.5
- Red Hat Enterprise Linux 7.6
- Ubuntu 16.04
- Ubuntu ® 18.04 LTS LTS
- CentOS 7.5
- CentOS 7.6
- SLES 12 SP3/SP4
- SLES 15
- All current versions of ESXi hypervisor
- Storage controller:
- PERC H330 in RAID or Non-RAID mode
Summary: You will only meet this issue with specific config.
- 14G AMD server + Linux OS + H330 controller
- 14G AMD server + ESXi + H330 configured as VMDirectPath I/O pass-through to a Linux VM
What is not affected?
- 14G Intel Platforms
- Any storage controller (HBA330/H730/H740/H840, etc.) other than H330
- Windows operating systems