Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Create and access a list of your products

PowerEdge: What is the Default Username and Password for an Integrated Dell Remote Access Controller (iDRAC)

Summary: This article provides information on the iDRAC default credentials, and how to rest the password.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Instructions

PowerEdge, PowerFlex, VxRail, PowerVault, and others systems with an iDRAC are available with a few options regarding the password as it comes from the factory. The choices are Secure Default Password, Legacy Password, and Force Change Password.

Default IP address

After purchasing the server you will have the option to request a specific configuration for the iDRAC which would include specifying a set IP address. Alternatively you can select to have the default settings, where the default IP address would be 10.14.186.21


Secure Default Password

By default, all PowerEdge servers ship with a unique, randomly generated iDRAC password, to provide additional security. This unique password is generated at the factory. It is located on the pull-out Service Tag on the front of the chassis, near the server asset tag. Customers who choose this option must write down this unique random password and use it to log in to iDRAC for the first time. For security purposes, Dell strongly recommends changing the default password.


Legacy Password

Customers who prefer the known legacy password "calvin" should choose this option. One reason to select this option would be to ensure conformance to current scripts. For security purposes, Dell strongly recommends changing the legacy password.
Customers should be aware the known legacy username "root" is what they should be using the with legacy password.

 

 

Note: Customers should be aware the legacy username "root" is what should be used the with unique and legacy password.

 


Force Change Password

The Force Change of Password feature prompts the user to change the factory default password of the device. The Force Change Password screen appears after successful user authentication and cannot be skipped. Only after the user enters a password, normal access and operation will be allowed.
 


You can reset the password through the iDRAC settings by pressing F2 at startup. Also, you can reset the password to its factory default with the following racadm command:

racadm racresetcfg -all

To reset the password to the legacy password, use the following racadm command:

racadm racresetcfg -rc

Note: More tutorials about the iDRAC are available in the Dell article Support Articles for the iDRAC and the CMC.

 


 

What is the "Default Password Warning" on iDRAC? (SEC0701)

The default iDRAC username and password are widely known, and any user can access the server and make changes using the default credentials. The Default Password Warning feature in iDRAC warns you if the default login credentials are still in place.

Whenever a user with Configure User privileges logs in to iDRAC or SSH or Telnet or runs racadm commands remotely using the default login credentials, the system displays a warning message (SEC0701). Because UI and SSH or Telnet users log in once per session, they see a single warning message for each session. Because remote racadm users log in for every command, they see a warning message for every command.

An iDRAC with default login credentials is even less secure if the system is Internet-accessible or part of a large network with different trust boundaries. If any of the following items is configured, the possibility exists that iDRAC could become accessible on the Internet.

Whenever a user with Configure User privileges logs in to iDRAC using Web UI using the default login credentials, the Default Password Warning Message displays. From this page, the user can either change the password for a root user, or they can change nothing and continue logging in to iDRAC. The option to disable the Default Password Warning Message appears on this page if the user does not change the password.
 

Screenshot of iDRAC login page with message

Figure 2: iDRAC9 default password warning.
 

iDRAC8 default password warning

Figure 3: iDRAC8 default password warning.


The Default Password Warning is enabled or disabled from the iDRAC Overview > iDRAC SettingsUser AuthenticationLocal Users page, under the section titled Default Password Warning.

 

 


 

I cannot remember the iDRAC password

If you have lost the iDRAC password, you must reset the iDRAC to its default setting. This process is explained in article How to Reset the Integrated Dell Remote Access Controller (iDRAC)

How to Log in to iDRAC9 With the Default Password.

 


Duration: 00:00:54 (hh:mm:ss)
When available, closed caption (subtitles) language settings can be chosen using the Settings or CC icon on this video player.

 

Connect to iDRAC8 & Change the Default Password

Duration: 00:01:26 (hh:mm:ss)
When available, closed caption (subtitles) language settings can be chosen using the CC icon on this video player.

Additional Information

Affected Products

iDRAC8, iDRAC9

Products

Dell EMC Microsoft Storage Spaces Direct Ready Nodes, OEMR R240, OEMR R250, OEMR R260, OEMR R340, OEMR R350, OEMR R360, OEMR R440, PowerEdge XR2, OEMR R450, OEMR R540, OEMR R550, OEMR R5500, OEMR R640, OEMR XL R640, OEMR R6415, OEMR R650, OEMR R650xs , OEMR R6515, OEMR R6525, OEMR R660, OEMR XL R660, OEMR R660xs, OEMR R6615, OEMR R6625, OEMR R740, OEMR XL R740, OEMR R740xd, OEMR XL R740xd, OEMR R740xd2, OEMR R7415, OEMR R7425, OEMR R750, OEMR R750xa, OEMR R750xs, OEMR R7515, OEMR R7525, OEMR R760, OEMR R760xa, OEMR R760XD2, OEMR XL R760, OEMR R760xs, OEMR R7615, OEMR R7625, OEMR R840, OEMR R860, OEMR R940, OEMR R940xa, OEMR R960, OEMR T340, OEMR T350, OEMR T360, OEMR T440, OEMR T550, OEMR T560, OEMR T640, OEMR XL T640, OEMR XL R240, OEMR XL R340, OEMR XL R660xs, OEMR XL R6615, OEMR XL R6625, OEMR XL R760xs, OEMR XL R7615, OEMR XL R7625, OEMR XR11, OEMR XR12, OEMR XR4510c, OEMR XR4520c, OEMR XR5610, OEMR XR7620, OEMR XR8610t, OEMR XR8620t, PowerEdge C4130, Poweredge C4140, PowerEdge c6300, PowerEdge c6320, PowerEdge c6320p, PowerEdge C6400, PowerEdge C6420, PowerEdge C6520, PowerEdge C6525, PowerEdge C6600, PowerEdge C6615, PowerEdge C6620, Poweredge FC430, Poweredge FC630, PowerEdge FC640, Poweredge FC830, PowerEdge FD332, PowerEdge FM120x4 (for PE FX2/FX2s), PowerEdge HS5610, PowerEdge HS5620, PowerEdge M630, PowerEdge M630 (for PE VRTX), PowerEdge M640, PowerEdge M640 (for PE VRTX), PowerEdge M830, PowerEdge M830 (for PE VRTX), PowerEdge MX5016s, PowerEdge MX740C, PowerEdge MX750c, PowerEdge MX760c, PowerEdge MX840C, PowerEdge R230, PowerEdge R240, PowerEdge R250, PowerEdge R260, PowerEdge R330, PowerEdge R340, PowerEdge R350, PowerEdge R360, PowerEdge R430, PowerEdge R440, PowerEdge R450, PowerEdge R530, PowerEdge R530xd, PowerEdge R540, PowerEdge R550, PowerEdge R630, PowerEdge R640, PowerEdge R6415, PowerEdge R650, PowerEdge R650xs, PowerEdge R6515, PowerEdge R6525, PowerEdge R660, PowerEdge R660xs, PowerEdge R6615, PowerEdge R6625, PowerEdge R670, PowerEdge R730, PowerEdge R730xd, PowerEdge R740, PowerEdge R740XD, PowerEdge R740XD2, PowerEdge R7415, PowerEdge R7425, PowerEdge R750, PowerEdge R750XA, PowerEdge R750xs, PowerEdge R7515, PowerEdge R7525, PowerEdge R760, PowerEdge R760XA, PowerEdge R760xd2, PowerEdge R760xs, PowerEdge R7615, PowerEdge R7625, PowerEdge R770, PowerEdge R830, PowerEdge R840, PowerEdge R860, PowerEdge R930, PowerEdge R940, PowerEdge R940xa, PowerEdge R960, PowerEdge T130, PowerEdge T140, PowerEdge T150, PowerEdge T30, PowerEdge T330, PowerEdge T340, PowerEdge T350, PowerEdge T360, PowerEdge T430, PowerEdge T440, PowerEdge T550, PowerEdge T560, PowerEdge T630, PowerEdge T640, PowerEdge XE2420, PowerEdge XE7100, PowerEdge XE7420, PowerEdge XE7440, PowerEdge XE8545, PowerEdge XE8640, PowerEdge XE9640, PowerEdge XE9680, PowerEdge XR11, PowerEdge XR12, PowerEdge XR4510c, PowerEdge XR4520c, PowerEdge XR5610, PowerEdge XR7620, PowerEdge XR8610t, PowerEdge XR8620t, PowerFlex appliance R650, PowerFlex appliance R6525, PowerFlex appliance R660, PowerFlex appliance R6625, Powerflex appliance R750, PowerFlex appliance R760, PowerFlex appliance R7625, PowerFlex custom node R650, PowerFlex custom node R6525, PowerFlex custom node R660, PowerFlex custom node R6625, PowerFlex custom node R750, PowerFlex custom node R760, PowerFlex custom node R7625, VxFlex Ready Node R640, Dell EMC vSAN C6420 Ready Node, Dell EMC vSAN MX740c Ready Node, Dell EMC vSAN MX750c Ready Node, Dell vSAN Ready Node MX760c, Dell EMC vSAN R440 Ready Node, Dell EMC vSAN R640 Ready Node, Dell EMC vSAN R6415 Ready Node, Dell EMC vSAN R650 Ready Node, Dell EMC vSAN R6515 Ready Node, Dell EMC vSAN R660 Ready Node, Dell vSAN R6615 Ready Node, Dell EMC vSAN R740 Ready Node, Dell EMC vSAN R740xd Ready Node, Dell EMC vSAN R750 Ready Node, Dell EMC vSAN R7515 Ready Node, Dell EMC vSAN R760 Ready Node, Dell vSAN R7615 Ready Node, Dell vSAN Ready Node R7625, Dell EMC vSAN R840 Ready Node, Dell EMC vSAN T350 Ready Node, PowerFlex appliance R640, PowerFlex appliance R740XD, PowerFlex appliance R7525, PowerFlex appliance R840 ...
Article Properties
Article Number: 000133536
Article Type: How To
Last Modified: 28 Nov 2024
Version:  25
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.