"Found SFM #, last power-cycle reason:", as highlighted below in a sample of show trace output.Force10#show trace 100 | grep SFM[2/19 13:18:59] RAM-(RpmAvailMgr):Send data sync msg (42) to task 4 SFM Config State ).[2/19 13:22:47] TSM-(tsm):Receive SFM 7 SFM_DETECT REMOVE event.[2/19 13:22:47] TSM-(tsm):tsmSfmRemove: Remove SFM 7[2/19 13:22:47] TSM-(tsm):tsmSfmRemove: SFM 7 is powered off.[2/19 13:22:48] TSM-(tsm):tsmSfmRemove: SFM 7 is powered on.[2/19 13:22:49] TSM-(tsm):Set SFM minor alarm[2/19 13:22:49] TSM-(tsm):tsmSfmRemove:8: SW FAB is good after removing SFM 7 [2/19 13:22:50] TSM-(tsm):Receive SFM 7 SFM_DETECT INSERT event. [2/19 13:22:50] TSM-(tsm):SFM 7 is reset with SFM Card insert event, bring up the card [2/19 13:22:50] TSM-(tsm):Found SFM 7, last power-cycle reason: power on with cause of DEFAULT [2/19 13:22:50] TSM-(tsm):TSM initilizes SFM 7... [2/19 13:22:51] ****** ERROR CHMGR-(chmgr):SFM 7 not present or bad slot id [2/19 13:22:52] TSM-(tsm):Clear SFM minor alarm [2/19 13:22:52] TSM-(tsm):tsmSfmAdd:8: LC is in service, no PP test. SFM 7 standby. numSfmFound = 9 [2/19 13:22:52] TSM-(tsm):Receive SFM 7 RESET_DETECT ASSERT event. [2/19 13:22:52] TSM-(tsm):SFM 7 reset is cleared, no action
show trace show logging Dec 30 11:12:20 PST: %RPM0:CP %CHMGR-2-MINOR_SFM: Minor alarm: No working standby SFM Dec 30 11:12:20 PST: %RPM0:CP %TSM-2-SFM_RESET_PRESENT: SFM 2 reset unexpectedly Dec 30 11:12:22 PST: %RPM0:CP %TSM-6-SFM_DISCOVERY: Found SFM 2 Dec 30 11:12:23 PST: %RPM0:CP %CHMGR-5-MINOR_SFM_CLR: Minor alarm cleared: Working standby SFM present Dec 30 11:12:23 PST: %RPM0:CP %TSM-6-SFM_DISCOVERY: Found 9 SFMs show sfm all
"m" - MDIO error "I" - I2C access error
Feb Feb 19 04:44:02: %RPM0:CP %TSM-6-SFM_SWITCHFAB_STATE: Switch Fabric: DOWN Feb 19 04:44:02: %RPM0:CP %TSM-2-SFM_GENERAL_ACCESS_M: SFM 3 found general access error (type m) Feb 19 04:44:05: %RPM0:CP %TSM-6-SFM_DISCOVERY: Found SFM 3 Feb 19 04:44:06: %RPM0:CP %TSM-6-SFM_SWITCHFAB_STATE: Switch Fabric: UP Feb 19 04:44:36: %RPM0:CP %TSM-6-SFM_SWITCHFAB_STATE: Switch Fabric: DOWN Feb 19 04:44:37: %RPM0:CP %CHMGR-0-MAJOR_SFM: Major alarm: Switch fabric down Feb 19 04:44:38: %RPM0:CP %TSM-2-SFM_UNDER_VOLT: SFM 3 powered off due to under voltage SFM Simba PSI access error
show trace Output [6/4 2:13:13] TSM-(tsm):Receive SFM 1 ERR_DETECT event [6/4 2:13:13] TSM-(tsm):tsmSfmRemove: Remove SFM 1 [6/4 2:13:13] TSM-(tsm):tsmSfmRemove: SFM 1 is powered off. [6/4 2:13:13] POLLER-(PM):doSfmSaSanErr: eventId=17, slotId=1, state=1, value[0]=0x1fd, value[1]=0x0 [6/4 2:13:14] TSM-(tsm):tsmSfmRemove: SFM 1 is powered on. [6/4 2:13:14] CHMGR-(chmgr):add min alrm 12 UNKNOWN 0 0 [6/4 2:13:14] CHMGR-(tsm):0x1382 log alrm 12 to chmgr (rc=84) [6/4 2:13:14] TSM-(tsm):Set SFM minor alarm [6/4 2:13:14] TSM-(tsm):Change SW FAB state from SW_FAB_UP_9 to SW_FAB_UP_8 !—The Etherscale supports one SFM in standby mode. The Terascale requires all 9 SFMs to be operationally active.[5/4 2:13:14] ***** WARNING TSM-(tsm):Turn off SFM 1 active LED fail. [5/4 2:13:14] ***** WARNING TSM-(tsm):Turn on SFM 1 Status LED Amber fail. !—During a failure, check the Status LED. [5/4 2:13:15] ****** ERROR TSM-(tsm):tsmIsSfmPowerOn: f10SysRpmSfmCardInfoGet() failed for SFM 1 power status [5/4 2:13:15] ****** ERROR TSM-(tsm):CheckSFMCardPower: tsmIsSfmPowerOn() failed for SFM 1 power status [5/4 2:13:15] ****** ERROR TSM-(tsm):tsmHandleSfmError: Different error detected on SFM 1 (erro = 262163). SFM already in SFM_ERROR state [6/4 2:13:15] TSM-(tsm):SFM 1 ERR_DETECT event is confirmed [6/4 2:13:15] TSM-(tsm):Receive SFM 1 SIMAB_DETECT event [5/4 2:13:15] ****** ERROR TSM-(tsm):tsmIsSFMReset: SFM 1 is not accessible via scratch pad (SFM_FAITH_CR = 0) [6/4 2:13:15] TSM-(tsm):tsmSfmRemove: Remove SFM 1 [6/4 2:13:15] TSM-(tsm):tsmSfmRemove: SFM 1 is powered off. [6/4 2:13:16] TSM-(tsm):tsmSfmRemove: SFM 1 is powered on. [5/4 2:13:16] ***** WARNING TSM-(tsm):Turn off SFM 1 active LED fail. [5/4 2:13:16] ***** WARNING TSM-(tsm):Turn on SFM 1 Status LED Amber fail. [5/4 2:13:17] ****** ERROR TSM-(tsm):tsmIsSfmPowerOn: f10SysRpmSfmCardInfoGet() failed for SFM 1 power status
show sfm all Force10#sh sfm all Switch Fabric State: up -- Switch Fabric Modules -- Slot Status --------------------------------------------------------------------------- 0 card problem (SFM Simba PSI access error) 1 active 2 active 3 active 4 active 5 active 6 active 7 active 8 active
Force10#show chassis brief Chassis Type : E300 Chassis Mode : TeraScale Chassis Epoch : 10.4 micro-seconds -- Line cards -- Slot Status NxtBoot ReqTyp CurTyp Version Ports --------------------------------------------------------------------------- 0 online online EX1YE3 EX1YE3 5.3.1.2b 1 1 online online EX1YE3 EX1YE3 5.3.1.2b 1 2 online online EX1YE3 EX1YE3 5.3.1.2b 1 3 online online EX1YE3 EX1YE3 5.3.1.2b 1 4 online online E12PE3 E12PE3 5.3.1.2b 12 5 not present -- Route Processor Modules -- Slot Status NxtBoot Version --------------------------------------------------------------------------- 0 active online 5.3.1.2b 1 not present Switch Fabric State: up -- Switch Fabric Modules -- Slot Status --------------------------------------------------------------------------- 0 SW FAB diags failed (Multiple SFMs failed SW FAB portpipe diags) 1 active [output omitted]
여러 조건에서 주요 경보가 보고됩니다. 이러한 조건 중 하나는 환경 모니터링 하드웨어 및 소프트웨어에서 감지되는 SFM 안전 작동 온도를 초과하는 것입니다. showenvironment 명령은 오류 메시지 외에도 고온 조건을 캡처할 수 있습니다.
Feb 27 04:52:16 UTC: %RPM0:CP %CHMGR-2-TEMP_SHUTDOWN_WARN: WARNING! SFM 6 temperature is 85C; approaching shutdown threshold of 80C) Feb 27 04:52:16 UTC: %RPM0:CP %CHMGR-2-MAJOR_TEMP: Major alarm: chassis temperature high (SFM temperature reaches or exceeds threshold of 75C) Feb 27 04:52:21 UTC: %RPM0:CP %CHMGR-2-MAJOR_TEMP_CLR: Major alarm cleared: chassis temperature lower (SFM 6 temperature is within threshold of 70C)
이 상태가 발생하면 SFM이 실제로 너무 뜨겁거나 센서가 오작동하는 것입니다. 바로 인접한 SFM이 정상 온도인 경우 센서 결함을 의심하십시오. 바로 인접한 SFM의 온도가 정상 온도가 아닌 경우 진짜 과열 상태를 의심하십시오.
시스템이 진짜 과열 상태를 감지하면 냉각될 때까지 그리고 소프트웨어에서 전원을 다시 켜도 안전하다고 판단할 때까지 SFM의 전원을 끕니다. 전원을 다시 공급하면 하드웨어에서 SFM 재설정 이유를 "과열"로 보고합니다. 소프트웨어가 온도 초과 이벤트를 감지하고 SFM을 수동으로 종료하는 경우 시스템에서 SFM 재설정 이유를 "원격 전원 꺼짐"으로 보고합니다.
프로그래밍된 경보 임계값 수준을 보려면 명령을 실행합니다 show alarms threshold :.
E600-TAC-3#show alarms threshold -- Temperature Limits (deg C) -- ----------------------------------------------------------- Minor Minor Off Major Major Off Shutdown Linecard 75 70 80 77 85 RPM 65 60 75 70 80 SFM 65 60 75 70 80
이 문제를 해결하려면 다음 단계를 수행하십시오.
reset sfm 명령을 통해 활성 SFM을 재설정하면 트래픽이 중단될 수 있으며 다음 메시지가 표시됩니다.
Force10#reset sfm 0 SFM 0 is active. Resetting it might temporarily impact traffic. Proceed with reset? Confirm [yes/no]:
저전압 상태로 인해 SFM의 전원이 꺼졌습니다.
Force10>show sfm 3 Switch Fabric State: up -- SFM card 3 -- Status : power off - SFM powered off due to under-voltage Card Type : SFM - Switch Fabric Module Up Time : 0 sec Temperature : 33C Power Status : PEM0: up PEM1: up Serial Number : 0012632 Part Number : 7520003706 Rev A Vendor Id : 01 Date Code : 01442003