Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Create and access a list of your products

PowerEdge: Troubleshooting a Server that Does Not Start-No Power, POST, Boot, or Video

Summary: This article provides PowerEdge server troubleshooting for No Power, No POST, No Boot and No Video issues. This includes blade, rack, and tower servers.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Instructions

Note: This article is part of the Server Tutorials: Support Tools, available from the article How-To Dell Server: Support Tutorials and Diagnostic Tools
 

Table of Content

  1. Definitions
  2. Before starting troubleshooting a Dell PowerEdge Server
  3. Troubleshooting No Power on a Dell PowerEdge Server
  4. Troubleshooting No POST on a Dell PowerEdge Server
  5. Troubleshooting No Boot on a Dell PowerEdge Server
  6. Troubleshooting No Video on a Dell PowerEdge Server

Definitions

No Power
Once the power button is pressed, no diagnostics LEDs are illuminated. The power button LED is also not illuminated. The system has no signs of power. The fan remains silent as it is not spinning. The iDRAC should not respond to pings. This is defined as no power. Follow the No Power troubleshooting steps below.

No Power On Self-Test (POST)
Your system appears to have power, but does not complete POST once the power button is pressed. During POST, the system goes through a series of internal checks. If any of these checks fail, the system shows an error on the LCD if present, or have LEDs illuminated to help indicate the potential problem. This is defined as no POST. Follow the No POST troubleshooting steps below.

No Boot
Once the system loads the Dell splash screen and finishes the POST checks, the Dell splash screen disappears and the system operation hands over to the operating system. If the operating system does not start for any reason, this is called a No Boot issue. A common symptom is also that there are not any boot device available, and the following error is displayed: "No boot device found." This also occurs if the virtual disks are not online due to a hard drive or PERC issue. Follow the No Boot troubleshooting steps below.

No Video
Once the power button is pressed, the system powers on and displays the POST checks where you may see the diagnostic LEDs illuminate briefly. The power button LED and the keyboard LEDs illuminate, but there are no signs of video on the display. If the iDRAC is working, and video output is seen in the virtual console (Virtual Console available for Enterprise licenses), you have a No Video situation. Follow the No Video troubleshooting steps below.

Return to Table of Content

Before starting troubleshooting a Dell PowerEdge Server

Collect the following information:
  • What events preceded the failure? After which steps does the problem occur?
  • What has been changed since the time that the server was working?
  • Did you recently add or remove hardware or software? If so, did you remember to change the appropriate settings in the server setup utility, if necessary?
  • How long has the server experienced problem symptoms?
  • If the problem occurs randomly, what is the duration or frequency?
Once you have obtained the following information, you should then check the iDRAC logs for additional information that can help with troubleshooting. (This is not possible for no power issues.) Log in to the iDRAC to view the logs. Also, view the LifeCycle logs as they may also aid troubleshooting.

iDRAC9: Go to MaintenanceLifeCycle Logs + System Event Logs.

iDRAC8: Go to Logs + LifeCycle Logs. How to export the iDRAC logs for Dell Tech Support and view the overall health of your system: For information about troubleshooting errors, see the Owner's Manual for the specific model. 

Return to Table of Content

Troubleshooting No Power on a Dell PowerEdge Server

Collect troubleshooting information as per Before starting troubleshooting a Dell PowerEdge Server. Return to Table of Content

Troubleshooting No POST on a Dell PowerEdge Server

Collect troubleshooting information as per Before starting troubleshooting a Dell PowerEdge Server.
  • Remove both power cables and then hold the power button in for ten seconds to drain any residual power.
  • Reconnect the power cables and then wait two minutes for the iDRAC to initialize before attempting to power on.
Confirm that the server is receiving power by checking if the power LED on the power supply is lit green.
Note: When removing or replacing parts, always remove the AC power cables and allow 10 seconds for the flea power to dissipate. After reinserting the AC power cable, allow two minutes before powering the server on. This allows time for the iDRAC to power on. Otherwise, error messages are not reported correctly.
See the appropriate Owner's Manual for detailed instructions on how to remove components.
  • Remove all external devices except the monitor (including mouse and keyboard).
    • After removing the devices, attempt to POST the server.
      • If the server now completes POST, plug the external devices back in one at a time until the defective device is found. Replace the defective device once it has been isolated.
      • If the server still does not complete POST, go to the next step.
  • Remove all third-party components and parts.
    • After removing the parts, attempt to POST the server.
      • If the server now completes POST, plug the parts back in one at a time until the defective part is found. Replace the defective part once it has been isolated.
      • If the server still does not complete POST, go to the next step.
  • Disconnect the hard drives from the server.
    • After removing the parts, attempt to POST the server.
      • If the server now completes POST, plug the parts back in one at a time until the defective part is found. Replace the defective part once it has been isolated.
      • If the server still does not complete POST, go to the next step.
  • Disconnect the optical drive and any internal tape drive.
    • After removing the parts, attempt to POST the server.
      • If the server now completes POST, plug the parts back in one at a time until the defective part is found. Replace the defective part once it has been isolated.
      • If the server still does not complete POST, go to the next step.
  • Remove PCI cards including integrated NDC/PERC if applicable.
    • After removing the parts, attempt to POST the server.
      • If the server now completes POST, plug the parts back in one at a time until the defective part is found. Replace the defective part once it has been isolated.
      • If the server still does not complete POST, go to the next step.
  • Reseat the control panel connector.
    • Certain platforms have a right and left control panel, review the configuration details for the system that you are working on for further details.
    • When working on 14G, 15G, 16G systems, and newer systems, considerations should be made to disconnect the control panels and attempt to power the server on from the rear system ID button as an alternative means of powering on the server. The chassis cover should be removed when attempting this troubleshooting step.  
  • Test with minimum to post. This is usually the power supply unit (PSU), motherboard, CPU 1, one stick of RAM, and the backplane. Full details for the minimum to post can be found in your Owner's Manual under Minimum to POST.
    • If the server now completes POST, plug the parts back in one at a time until the defective part is found. Replace the defective part once it has been isolated.
Note: For Multi-Processor, Multi-DIMM, or Multi-PSU configurations, if the server is not posting in a minimum to post configuration the CPU (typically CPU1), single DIMM (typically A1), and PSU should be swapped out with parts that were previously removed from the server to verify that they are not the cause of the no post. For example, testing CPU2 in the CPU1 socket with the original CPU1 removed from the server or swapping out DIMM A1 with a different DIMM that was previously removed from the server.
  • If the server still does not complete POST, the remaining parts have to be considered (for example, the motherboard, backplane, control panel, and PDU).
Return to Table of Content

Troubleshooting No Boot on a Dell PowerEdge Server

Collect troubleshooting information as per Before starting troubleshooting a Dell PowerEdge Server. No boot means that the server powers on and the Dell screen appears, but when the operating system should be loaded, the error "No Boot Device Available" is displayed and nothing happens.

After the server completes the power-on self-test (POST) phase, it tries to boot a bootable device. A bootable device is any piece of hardware that can either read the files or contains the files that are required for a system to start. A default bootable media can be selected in the BIOS. By default, the raid controller card (PERC) is selected first. Files available in a bootable device (RAID, USB drive, DVD, ISO file) contain instructions to start the operating system. When these files cannot be found, the No Boot Device Available error is displayed.

A few actions can be performed to check what is not working properly.

Resolution: Manually select the boot device.

The first thing to check is which device is selected as the primary boot. To do a quick check, use F11 to launch the manual boot selection.
  1. Restart the system.
  2. Press F11 during POST to enter the Boot Manager.
  3. Select the correct Hard Disk drive (Virtual Drive), where the operating system is installed.
  4. Boot from this device.
If the system now boots into the operating system, the hardware is fine, and there is a boot order conflict in the BIOS settings. The most likely cause is that the system is set to boot from CD, DVD, or USB before the drives, which is a logical setting. To resolve this, ensure you do not have a USB or CD or DVD inserted when powering on the system.
 
Note: Wrong settings in the boot mode can also cause this error. An operating system that is installed in UEFI mode cannot boot in BIOS mode and the opposite way.

You can change the boot order setting permanently in the System Setup to boot from the drive first. To change this:
  1. Restart the system.
  2. Press F2 during system start to enter the System Settings.
  3. Change the Boot Sequence in the Boot Settings.
  4. Leave the menu using Exit in the upper right corner of the screen.
Note: After this, you must press F11 if you want to boot from a CD, DVD, or USB later.

Return to Table of Content

Troubleshooting No Video on a Dell PowerEdge Server

Collect troubleshooting information as per Before starting troubleshooting a Dell PowerEdge Server. If the server has completed post and booted to the operating system, but the system has no video on a directly connected monitor.
  • Check that monitor input selection is set to the correct input.
  • If using a KVM, ensure that the correct system is selected.
  • Remove the monitor cable to perform the monitor self-test to ensure that the monitor is operational.
  • If the monitor fails the self-test, test with another monitor. For more information, see article How to Run a Diagnostic Test on a Dell Monitor.
  • Swap the monitor cable with a knowing working cable.
  • Bypass any KVM and test directly on the front and the rear output of the server.
  • If the monitor fails on only the front panel connection, try to reseat the front panel cable connection if applicable. If reseating the cable does not help, replace the front control panel.
  • Confirm that the monitor cable is connected to the correct video output on the server. If an add-on video card has been installed, be sure that the monitor cable is connected to it rather than the integrated video source.
  • Power drain the server then check for video on post to rule out the operating system. For more information, see article How do I Reset and Drain Power of my Dell PowerEdge Server?
  • Ensure that the monitor cable is connected to the first video card based on PCIe enumeration when the embedded video controller is set to disabled.
If the system is still showing no video from the front panel and the rear, contact Dell Support.

Return to Table of Content

Affected Products

OEMR R230, OEMR R240, OEMR R250, OEMR XE R250, OEMR R260, OEMR XE R260, OEMR R330, OEMR R340, OEMR R350, OEMR XE R350, OEMR R360, OEMR XE R360, OEMR R430, OEMR R440, PowerEdge XR2, OEMR R450, OEMR R530, OEMR R540, OEMR R550, OEMR R5500, OEMR R630 , OEMR R640, OEMR XL R640, OEMR R6415, OEMR R650, OEMR R650xs, OEMR R6515, OEMR R6525, OEMR R660, OEMR XL R660, OEMR R660xs, OEMR R6615, OEMR R6625, OEMR R730, OEMR R730xd, OEMR R740, OEMR XL R740, OEMR R740xd, OEMR XL R740xd, OEMR R740xd2, OEMR R7415, OEMR R7425, OEMR R750, OEMR R750xa, OEMR R750xs, OEMR R7515, OEMR R7525, OEMR R760, OEMR R760xa, OEMR R760XD2, OEMR XL R760, OEMR R760xs, OEMR R7615, OEMR R7625, OEMR R830, OEMR R840, OEMR R860, OEMR R930, OEMR R940, OEMR R940xa, OEMR R960, OEMR T130, OEMR T140, OEMR T150, OEMR T330, OEMR T340, OEMR T350, OEMR T360, OEMR T430, OEMR T440, OEMR T550, OEMR T560, OEMR T630, OEMR T640, OEMR XL R230, OEMR XL R240, OEMR XL R330, OEMR XL R340, OEMR XL R630, OEMR XL R660xs, OEMR XL R6615, OEMR XL R6625, OEMR XL R6715, OEMR XL R6725, OEMR XL R730, OEMR XL R730XD, OEMR XL R760xs, OEMR XL R7615, OEMR XL R7625, OEMR XL R7715, OEMR XL R7725, OEMR XR11, OEMR XR12, OEMR XR5610, OEMR XR7620, PowerEdge R230, PowerEdge R240, PowerEdge R250, PowerEdge R260, PowerEdge R330, PowerEdge R340, PowerEdge R350, PowerEdge R360, PowerEdge R430, PowerEdge R440, PowerEdge R450, PowerEdge R470, PowerEdge R530, PowerEdge R530xd, PowerEdge R540, PowerEdge R550, PowerEdge R630, PowerEdge R640, PowerEdge R6415, PowerEdge R650, PowerEdge R650xs, PowerEdge R6515, PowerEdge R6525, PowerEdge R660, PowerEdge R660xs, PowerEdge R6615, PowerEdge R6625, PowerEdge R670, PowerEdge R730, PowerEdge R730xd, PowerEdge R740, PowerEdge R740XD, PowerEdge R740XD2, PowerEdge R7415, PowerEdge R7425, PowerEdge R750, PowerEdge R750XA, PowerEdge R750xs, PowerEdge R7515, PowerEdge R7525, PowerEdge R760, PowerEdge R760XA, PowerEdge R760xd2, PowerEdge R760xs, PowerEdge R7615, PowerEdge R7625, PowerEdge R770, PowerEdge R7715, PowerEdge R7725, PowerEdge R830, PowerEdge R840, PowerEdge R860, PowerEdge R930, PowerEdge R940, PowerEdge R940xa, PowerEdge R960, PowerEdge T130, PowerEdge T140, PowerEdge T150, PowerEdge T160, PowerEdge T30, PowerEdge T330, PowerEdge T340, PowerEdge T350, PowerEdge T360, PowerEdge T40, PowerEdge T430, PowerEdge T440, PowerEdge T550, PowerEdge T560, PowerEdge T630, PowerEdge T640, PowerEdge XE2420, PowerEdge XE7100, PowerEdge XE7420, PowerEdge XE7440, PowerEdge XE8545, PowerEdge XE8640, PowerEdge XE9640, PowerEdge XE9680, PowerEdge XR11, PowerEdge XR12, PowerEdge XR5610, PowerEdge XR7620, Dell EMC vSAN R440 Ready Node, Dell EMC vSAN R640 Ready Node, Dell EMC vSAN R6415 Ready Node, Dell EMC vSAN R650 Ready Node, Dell EMC vSAN R6515 Ready Node, Dell EMC vSAN R660 Ready Node, Dell EMC vSAN R740 Ready Node, Dell EMC vSAN R740xd Ready Node, Dell EMC vSAN R750 Ready Node, Dell EMC vSAN R7515 Ready Node, Dell EMC vSAN R760 Ready Node, Dell vSAN R7615 Ready Node, Dell vSAN Ready Node R7625, Dell EMC vSAN R840 Ready Node, Dell EMC vSAN T350 Ready Node ...
Article Properties
Article Number: 000152161
Article Type: How To
Last Modified: 17 Dec 2024
Version:  19
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.