"Found SFM #, last power-cycle reason:", as highlighted below in a sample of show trace output.Force10#show trace 100 | grep SFM[2/19 13:18:59] RAM-(RpmAvailMgr):Send data sync msg (42) to task 4 SFM Config State ).[2/19 13:22:47] TSM-(tsm):Receive SFM 7 SFM_DETECT REMOVE event.[2/19 13:22:47] TSM-(tsm):tsmSfmRemove: Remove SFM 7[2/19 13:22:47] TSM-(tsm):tsmSfmRemove: SFM 7 is powered off.[2/19 13:22:48] TSM-(tsm):tsmSfmRemove: SFM 7 is powered on.[2/19 13:22:49] TSM-(tsm):Set SFM minor alarm[2/19 13:22:49] TSM-(tsm):tsmSfmRemove:8: SW FAB is good after removing SFM 7 [2/19 13:22:50] TSM-(tsm):Receive SFM 7 SFM_DETECT INSERT event. [2/19 13:22:50] TSM-(tsm):SFM 7 is reset with SFM Card insert event, bring up the card [2/19 13:22:50] TSM-(tsm):Found SFM 7, last power-cycle reason: power on with cause of DEFAULT [2/19 13:22:50] TSM-(tsm):TSM initilizes SFM 7... [2/19 13:22:51] ****** ERROR CHMGR-(chmgr):SFM 7 not present or bad slot id [2/19 13:22:52] TSM-(tsm):Clear SFM minor alarm [2/19 13:22:52] TSM-(tsm):tsmSfmAdd:8: LC is in service, no PP test. SFM 7 standby. numSfmFound = 9 [2/19 13:22:52] TSM-(tsm):Receive SFM 7 RESET_DETECT ASSERT event. [2/19 13:22:52] TSM-(tsm):SFM 7 reset is cleared, no action
show trace show logging Dec 30 11:12:20 PST: %RPM0:CP %CHMGR-2-MINOR_SFM: Minor alarm: No working standby SFM Dec 30 11:12:20 PST: %RPM0:CP %TSM-2-SFM_RESET_PRESENT: SFM 2 reset unexpectedly Dec 30 11:12:22 PST: %RPM0:CP %TSM-6-SFM_DISCOVERY: Found SFM 2 Dec 30 11:12:23 PST: %RPM0:CP %CHMGR-5-MINOR_SFM_CLR: Minor alarm cleared: Working standby SFM present Dec 30 11:12:23 PST: %RPM0:CP %TSM-6-SFM_DISCOVERY: Found 9 SFMs show sfm all
"m" - MDIO error "I" - I2C access error
Feb Feb 19 04:44:02: %RPM0:CP %TSM-6-SFM_SWITCHFAB_STATE: Switch Fabric: DOWN Feb 19 04:44:02: %RPM0:CP %TSM-2-SFM_GENERAL_ACCESS_M: SFM 3 found general access error (type m) Feb 19 04:44:05: %RPM0:CP %TSM-6-SFM_DISCOVERY: Found SFM 3 Feb 19 04:44:06: %RPM0:CP %TSM-6-SFM_SWITCHFAB_STATE: Switch Fabric: UP Feb 19 04:44:36: %RPM0:CP %TSM-6-SFM_SWITCHFAB_STATE: Switch Fabric: DOWN Feb 19 04:44:37: %RPM0:CP %CHMGR-0-MAJOR_SFM: Major alarm: Switch fabric down Feb 19 04:44:38: %RPM0:CP %TSM-2-SFM_UNDER_VOLT: SFM 3 powered off due to under voltage SFM Simba PSI access error
show trace Output [6/4 2:13:13] TSM-(tsm):Receive SFM 1 ERR_DETECT event [6/4 2:13:13] TSM-(tsm):tsmSfmRemove: Remove SFM 1 [6/4 2:13:13] TSM-(tsm):tsmSfmRemove: SFM 1 is powered off. [6/4 2:13:13] POLLER-(PM):doSfmSaSanErr: eventId=17, slotId=1, state=1, value[0]=0x1fd, value[1]=0x0 [6/4 2:13:14] TSM-(tsm):tsmSfmRemove: SFM 1 is powered on. [6/4 2:13:14] CHMGR-(chmgr):add min alrm 12 UNKNOWN 0 0 [6/4 2:13:14] CHMGR-(tsm):0x1382 log alrm 12 to chmgr (rc=84) [6/4 2:13:14] TSM-(tsm):Set SFM minor alarm [6/4 2:13:14] TSM-(tsm):Change SW FAB state from SW_FAB_UP_9 to SW_FAB_UP_8 !—The Etherscale supports one SFM in standby mode. The Terascale requires all 9 SFMs to be operationally active.[5/4 2:13:14] ***** WARNING TSM-(tsm):Turn off SFM 1 active LED fail. [5/4 2:13:14] ***** WARNING TSM-(tsm):Turn on SFM 1 Status LED Amber fail. !—During a failure, check the Status LED. [5/4 2:13:15] ****** ERROR TSM-(tsm):tsmIsSfmPowerOn: f10SysRpmSfmCardInfoGet() failed for SFM 1 power status [5/4 2:13:15] ****** ERROR TSM-(tsm):CheckSFMCardPower: tsmIsSfmPowerOn() failed for SFM 1 power status [5/4 2:13:15] ****** ERROR TSM-(tsm):tsmHandleSfmError: Different error detected on SFM 1 (erro = 262163). SFM already in SFM_ERROR state [6/4 2:13:15] TSM-(tsm):SFM 1 ERR_DETECT event is confirmed [6/4 2:13:15] TSM-(tsm):Receive SFM 1 SIMAB_DETECT event [5/4 2:13:15] ****** ERROR TSM-(tsm):tsmIsSFMReset: SFM 1 is not accessible via scratch pad (SFM_FAITH_CR = 0) [6/4 2:13:15] TSM-(tsm):tsmSfmRemove: Remove SFM 1 [6/4 2:13:15] TSM-(tsm):tsmSfmRemove: SFM 1 is powered off. [6/4 2:13:16] TSM-(tsm):tsmSfmRemove: SFM 1 is powered on. [5/4 2:13:16] ***** WARNING TSM-(tsm):Turn off SFM 1 active LED fail. [5/4 2:13:16] ***** WARNING TSM-(tsm):Turn on SFM 1 Status LED Amber fail. [5/4 2:13:17] ****** ERROR TSM-(tsm):tsmIsSfmPowerOn: f10SysRpmSfmCardInfoGet() failed for SFM 1 power status
show sfm all Force10#sh sfm all Switch Fabric State: up -- Switch Fabric Modules -- Slot Status --------------------------------------------------------------------------- 0 card problem (SFM Simba PSI access error) 1 active 2 active 3 active 4 active 5 active 6 active 7 active 8 active
Force10#show chassis brief Chassis Type : E300 Chassis Mode : TeraScale Chassis Epoch : 10.4 micro-seconds -- Line cards -- Slot Status NxtBoot ReqTyp CurTyp Version Ports --------------------------------------------------------------------------- 0 online online EX1YE3 EX1YE3 5.3.1.2b 1 1 online online EX1YE3 EX1YE3 5.3.1.2b 1 2 online online EX1YE3 EX1YE3 5.3.1.2b 1 3 online online EX1YE3 EX1YE3 5.3.1.2b 1 4 online online E12PE3 E12PE3 5.3.1.2b 12 5 not present -- Route Processor Modules -- Slot Status NxtBoot Version --------------------------------------------------------------------------- 0 active online 5.3.1.2b 1 not present Switch Fabric State: up -- Switch Fabric Modules -- Slot Status --------------------------------------------------------------------------- 0 SW FAB diags failed (Multiple SFMs failed SW FAB portpipe diags) 1 active [output omitted]
Velký poplach je hlášen za několika podmínek. Jedním z takových stavů je překročení bezpečné provozní teploty SFM, jak ji detekuje hardware a software pro monitorování prostředí. Příkaz showenvironment může kromě chybových zpráv zachytit také vysokou teplotu:
Feb 27 04:52:16 UTC: %RPM0:CP %CHMGR-2-TEMP_SHUTDOWN_WARN: WARNING! SFM 6 temperature is 85C; approaching shutdown threshold of 80C) Feb 27 04:52:16 UTC: %RPM0:CP %CHMGR-2-MAJOR_TEMP: Major alarm: chassis temperature high (SFM temperature reaches or exceeds threshold of 75C) Feb 27 04:52:21 UTC: %RPM0:CP %CHMGR-2-MAJOR_TEMP_CLR: Major alarm cleared: chassis temperature lower (SFM 6 temperature is within threshold of 70C)
Pokud k tomuto stavu dochází, buď je SFM skutečně příliš horký, nebo došlo k poruše senzoru. Pokud mají přímo sousedící SFM normální teplotu, máte podezření na vadný snímač. Pokud přímo sousedící SFM nemají normální teplotu, máte podezření na skutečné přehřátí.
Když systém zjistí skutečnou přehřívání, vypne modul SFM, dokud nevychladne a dokud software neurčí, že je bezpečné jej znovu zapnout. Po opětovném zapnutí bude hardware hlásit důvod resetování SFM jako "přehřátí". Pokud software detekuje přehřátí a ručně vypne modul SFM, systém nahlásí reset modulu SFM jako důvod "vzdálené vypnutí".
Na view naprogramované prahové úrovně alarmů, spusťte příkaz show alarms threshold :.
E600-TAC-3#show alarms threshold -- Temperature Limits (deg C) -- ----------------------------------------------------------- Minor Minor Off Major Major Off Shutdown Linecard 75 70 80 77 85 RPM 65 60 75 70 80 SFM 65 60 75 70 80
K řešení tohoto problému použijte následující postup:
Resetování aktivního modulu SFM pomocí příkazu reset sfm může způsobit přerušení přenosu a tato zpráva:
Force10#reset sfm 0 SFM 0 is active. Resetting it might temporarily impact traffic. Proceed with reset? Confirm [yes/no]:
SFM je vypnutý kvůli podpětí
Force10>show sfm 3 Switch Fabric State: up -- SFM card 3 -- Status : power off - SFM powered off due to under-voltage Card Type : SFM - Switch Fabric Module Up Time : 0 sec Temperature : 33C Power Status : PEM0: up PEM1: up Serial Number : 0012632 Part Number : 7520003706 Rev A Vendor Id : 01 Date Code : 01442003