Symptoms

NetWorker VMware Protection 整合是透過 vProxy 裝置進行設定。  NetWorker Management Console (NMC) 中已設定即時存取還原,但無法完成並顯示訊息:
Virtual machine recovery failed: Unable to find a configured device for recovery of saveset [SAVE_SET_ID]: Management credentials for setting up export path were not configured on NSR Data Domain '[DATA_DOMAIN_NAME]'.
復原組態
 

Cause

Data Domain 資源中的管理主機詳細資料不正確。  尚未設定管理主機詳細資料或管理使用者密碼已變更。

Resolution

更新管理主機詳細資料:
  1. 以 NetWorker 伺服器的系統管理員身分登入 NMC GUI。
  2. 按一下工作列上的 Enterprise 按鈕。
  3. 在導覽樹狀結構中反白顯示主機,在 NetWorker 按一下滑鼠右鍵,然後選取 啟動應用程式。NetWorker 管理視窗隨即出現。
  4. 按一下工作列上的 裝置 按鈕。
  5. 在展開的左側導覽窗格中,選取 Data Domain 系統
  6. 在右側詳細資料窗格中,以滑鼠右鍵按一下 Data Domain 系統 ,然後選取 內容
  7. 在 NSR Data Domain 內容視窗存取區段中,輸入 管理主機、管理使用者和管理密碼。  管理使用者應具有 DD 管理員權限。
  8. 建議將此欄位保留空白,但如果需要,可在 NSR Data Domain 內容視窗組態區段中更新匯出路徑。  
  9. 選擇 「確定 」以保存更改。