Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Enjoy members-only rewards and discounts
  • Create and access a list of your products
Some article numbers may have changed. If this isn't what you're looking for, try searching all articles. Search articles

PowerStore: Clusters that have SAS Expansion Enclosures may experience unexpected node reboots when running PowerStoreOS versions 3.0 to 3.5

Summary: Clusters that have one or more SAS Expansion Enclosures, may experience unexpected node reboots when running PowerStoreOS versions 3.0 to 3.5.

This article applies to   This article does not apply to 

Symptoms

The PowerStore nodes may unexpectedly reboot if these conditions are met:
  • The cluster is on PowerStoreOS version 3.0.x, 3.2.x, or 3.5.x.
  • There are one or more SAS expansion enclosures attached to any of the appliances in the cluster.

Cause

The SAS drivers may time out due to a lock issue on the SAS controller.
This in turn causes a node unexpected reboot.

Resolution

The issue is resolved in PowerStoreOS version 3.6 and above.

Affected Products

PowerStore
Article Properties
Article Number: 000203131
Article Type: Solution
Last Modified: 20 May 2024
Version:  23
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.